    Entry number 251537

    keyword=End_of_Run_4074
    ****************************
     Run Number: 4074
     End of Run Comment:
    Run_type=Production,target_type=Polarized 3He,targetpol_poldir=Transverse-in-plane,targetpol_pol=65,beam_e0=5.892,beam_raster=on,leftarm_p=2.35,leftarm_theta=16,leftarm_sieve=out,bbarm_i=710,bbarm_theta=30,bbarm_sieve=out,bbarm_zoff=0,comment_text=Production run with test DAQ for RICH: CRAMS_MAX_CHAN=120 back to nominal, Happex Run 30487
     
    
    PRESCALE FACTORS:ps1=2100   ps2=16777215   ps3=27   ps4=16777215   ps5=1   ps6=100   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 884740       [++]: 197027       [--]: 238530       [+-]: 197047       [-+]: 237675       
    TIME     : [ 0]: 58.124 mins  [++]: 13.619 mins  [--]: 14.994 mins  [+-]: 13.592 mins  [-+]: 15.039 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -2.11939 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:   9.42%      [++]:   9.44%      [--]:   9.31%      [+-]:   9.43%      [-+]:   9.51%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] :36.1/75858.0 Hz   T2[ 0] : 0.0/12.7 Hz   T3[ 0] :40.8/1102.9 Hz   T4[ 0] : 0.0/36.2 Hz   T5[ 0] :36.6/36.6 Hz   T6[ 0] :157.7/15770.7 Hz   T7[ 0] : 0.0/12.9 Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] :34.2/71758.4 Hz   T2[++] : 0.0/12.6 Hz   T3[++] :38.6/1042.9 Hz   T4[++] : 0.0/34.6 Hz   T5[++] :35.4/35.4 Hz   T6[++] :149.2/14920.2 Hz   T7[++] : 0.0/12.7 Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] :37.8/79376.4 Hz   T2[--] : 0.0/12.8 Hz   T3[--] :42.7/1154.2 Hz   T4[--] : 0.0/37.3 Hz   T5[--] :37.9/37.9 Hz   T6[--] :165.2/16515.8 Hz   T7[--] : 0.0/12.9 Hz   T8[--] :10.2/1024.0 Hz   
    T1[+-] :34.3/71970.0 Hz   T2[+-] : 0.0/12.8 Hz   T3[+-] :38.8/1047.5 Hz   T4[+-] : 0.0/34.9 Hz   T5[+-] :35.3/35.3 Hz   T6[+-] :149.6/14955.5 Hz   T7[+-] : 0.0/13.0 Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] :37.7/79206.8 Hz   T2[-+] : 0.0/12.7 Hz   T3[-+] :42.6/1151.0 Hz   T4[-+] : 0.0/37.5 Hz   T5[-+] :37.3/37.3 Hz   T6[-+] :164.6/16462.4 Hz   T7[-+] : 0.0/12.8 Hz   T8[-+] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] : 125975/264548917  T2[ 0] :      0/44345    T3[ 0] : 142450/3846155  T4[ 0] :      0/126222   T5[ 0] : 127699/127699   T6[ 0] : 549991/54999168  T7[ 0] :      0/44876    T8[ 0] :  35711/3571121  
    T1[++] :  27921/58635217  T2[++] :      0/10314    T3[++] :  31562/852189   T4[++] :      0/28265    T5[++] :  28956/28956    T6[++] : 121916/12191629  T7[++] :      0/10377    T8[++] :   8367/836731   
    T1[--] :  34003/71408280  T2[--] :      0/11491    T3[--] :  38456/1038327  T4[--] :      0/33579    T5[--] :  34129/34129    T6[--] : 148578/14857856  T7[--] :      0/11634    T8[--] :   9212/921207   
    T1[+-] :  27948/58692518  T2[+-] :      0/10443    T3[+-] :  31638/854235   T4[+-] :      0/28431    T5[+-] :  28808/28808    T6[+-] : 121963/12196385  T7[+-] :      0/10564    T8[+-] :   8350/835086   
    T1[-+] :  34034/71471414  T2[-+] :      0/11459    T3[-+] :  38464/1038551  T4[-+] :      0/33836    T5[-+] :  33693/33693    T6[-+] : 148546/14854687  T7[-+] :      0/11572    T8[-+] :   9239/923995   
    
    AVERAGE CURRENT
    BCM x1 : 9.7854 uA  BCM x3 : 9.7851 uA  BCM x10: 9.2157 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :      170 ppm     BCM u3 :   -15.19 ppm     BCM u10:   -29.46 ppm     
    BCM d1 :    86.99 ppm     BCM d3 :      689 ppm     BCM d10:    139.8 ppm     
    
    Target -
    BCM u1 :    131.7 ppm     BCM u3 :    169.1 ppm     BCM u10:      159 ppm     
    BCM d1 :    223.2 ppm     BCM d3 :    166.1 ppm     BCM d10:    266.6 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:0.03449        BCM u3 [ 0]:0.03447        BCM u10[ 0]:0.0305         
    BCM u1 [++]:0.007655       BCM u3 [++]:0.007645       BCM u10[++]:0.006762       
    BCM u1 [--]:0.009306       BCM u3 [--]:0.009306       BCM u10[--]:0.008235       
    BCM u1 [+-]:0.007652       BCM u3 [+-]:0.007645       BCM u10[+-]:0.006763       
    BCM u1 [-+]:0.009308       BCM u3 [-+]:0.00931        BCM u10[-+]:0.008237       
    
    BCM d1 [ 0]:0.03376        BCM d3 [ 0]:0.03378        BCM d10[ 0]:0.03378        
    BCM d1 [++]:0.007489       BCM d3 [++]:0.007499       BCM d10[++]:0.007492       
    BCM d1 [--]:0.009115       BCM d3 [--]:0.009121       BCM d10[--]:0.009122       
    BCM d1 [+-]:0.007487       BCM d3 [+-]:0.007489       BCM d10[+-]:0.00749        
    BCM d1 [-+]:0.009119       BCM d3 [-+]:0.009124       BCM d10[-+]:0.009127       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4074 at Sun Nov 30 21:29:03 EST 2008
    
    Wien angle : 31.1993
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 2.35006
    Left Arm arm angle : 16.0026
    HALLA:p : 5892.05
    HALLA:dpp : -1.27961e-06
    Tiefenbach Hall A energy : 5892.05
    Left Arm Top VDC Current : 0.146484
    Left Arm Bottom VDC Current : -1.36719
    -----
    Left Arm Q1 momentum : 2.35042
    Left Arm Q1 power supply : 1768.29
    Left Arm Q1 gauss meter : -0.14993
    Left Arm Q2 gauss meter : 0.5322
    Left Arm Q2 power supply current : 1011.99
    Left Arm Q2 momentum : 2.35018
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 804.502
    Left Arm D1 momentum : 2.35006
    Left Arm D1 NMR : 0.869671
    Left Arm Q3 gauss meter : -0.47194
    Left Arm Q3 power supply current : 935.55
    Left Arm Q3 momentum : 2.34993
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 710
    BigBite magnet current readback : 706.569
    BigBite Gaussmeter readback : 1.2139
    -----
    Average current of the two cavities : 0.334183
    Current on Unser monitor : -5.98449
    Current on Upstream bcm : 0.33331
    Current on Downstream bcm : 0.335057
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 0.283809
    Hall C Current : 4.0602
    MBSY1c magnet current (amp) : 246.901
    MBSY1c Bdl : 1.47358e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 5892.05
    Hall A momentum orbit correction (dpp) : -1.27961e-06
    Hall A setup momentum (MMSHLAE) : 5900.64
    Hall A energy (halla_MeV) : 5892.05
    Hall C energy (hallc_MeV) : 5904.21
    Delta(E)/E width (MV_AI_DXWID) : 2.61718
    IPM1C12.XPOS : -0.0454335
    IPM1H04A.XPOS : 0.188256
    IPM1H04A.YPOS : 1.50217
    IPM1H04B.XPOS : -1.49698
    IPM1H04B.YPOS : 1.13263
    -----
    HacL_HPE1313A:0_Ch58 : -0.182129
    HacL_HPE1313A:0_Ch55 : 23.7793
    HacL_HPE1313A:0_Ch54 : 0.0820312
    Left Arm Angle Vernier : 31.5
    Left Arm Scattering Angle : 16.0026
    Left VDC -DISC LVL Top : 3.896
    Left VDC -DISC LVL Bottom : 3.96094
    Left VDC -DISC LVL Voltage1 : 4.97266
    Left VDC -DISC LVL Voltage2 : -5.06348
    -----
    Wien angle : 31.1993
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 713.25
    Wien field : 20.72
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    RICH Vmon 16 : 2204.2
    RICH Imon 16 : CAENdatC --- Invalid channel name 1M2Ch16.NLK --- Invalid channel name
    RICH Vmon 17 : 201
    RICH Imon 17 : 0
    RICH Radiator Oxygen : -1.66016
    RICH Radiator Moisture : 317.676
    RICH Radiator Pressure : 9.72217
    RICH Condensor temperature : -9.08398
    RICH Gas Oxygen : 5.56641
    RICH Gas Moisture : 11.2305
    RICH Argon Flow : 0.585938
    RICH Methane Flow : 1552.73
    RICH A Volts : 3.80762
    RICH B Volts : 3.88184
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.0355341
    SLI Energy spread *10^5 : 0.888351
    SLI x position : 1.77391
    SLI vert. size mm : 0
    SLI y position : 0.683568
    -----
    Polarized 3He Target
    RTD1 (upstream) : 41.3086
    RTD2 : 55.7324
    RTD3 : 155.576
    RTD4 : 76.6309
    RTD5 (downstream) : 42.4707
    RTD6 (pump cell up) : 243.809
    RTD7 (pump cell down) : 256.992
    HacAi_hpchan7: Temp at Ref. Cell : 38.75
    HacAi_hpchan8: Temp at Ref. Cell : 56.2012
    HacAi_hpchan9: Temp at Ref. Cell : 38.9844
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -9.37
    Oven Air Flow : 229.7
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : 229.4
    HacOMEGA_SP1 : 230
    HacOMEGA_PROP1 : 300
    HacOMEGA_RST1 : 3000
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 0
    CLASER_TEMP : 0
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 6
    CLASER3_TEMP : 23
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP : 0
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 0
    CLASER5_TEMP : 0
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 0
    CLASER6_TEMP : 0
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0011
    ntc1_temp : 26.0348
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.002
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9971
    ntc3_temp : 25
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : -4.621
    DDM45_2disp1_read : 6.232
    DDM45_3disp1_read : 6.232
    ----
    haPolHe3_Spin_State : 1
    haPolHe3_Flip_Sequence_ID : 269
    haPolHe3_Flip_Count : 139
    haPolHe3_EPR_ID : 11281520
    haPolHe3_EPR_POL : 53.8739
    haPolHe3_Last_Flip_Start : 21:21:14 11/30/2008nit
    haPolHe3_Last_Flip_End : 21:21:19 11/30/2008nit
    haPolHe3_FLIP_NMR_PHASE : 178.746
    haPolHe3_FLIP_NMR_Mag : 22.2362
    haPolHe3_FLIP_NMR_Pol : 64.8677
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : enabled
    HaGenTargPos : -9.37
    ----