     Run Number: 4075
     End of Run Comment:
    Run_type=Production,target_type=Polarized 3He,targetpol_poldir=Transverse-in-plane,targetpol_pol=65,beam_e0=5.892,beam_raster=on,leftarm_p=2.35,leftarm_theta=16,leftarm_sieve=out,bbarm_i=710,bbarm_theta=30,bbarm_sieve=out,bbarm_zoff=0,comment_text=Production run with test DAQ for RICH: CRAMS_MAX_CHAN=120 back to nominal, Happex Run 30487
     
    
    PRESCALE FACTORS:ps1=2100   ps2=16777215   ps3=27   ps4=16777215   ps5=1   ps6=100   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 997297       [++]: 218593       [--]: 271251       [+-]: 218611       [-+]: 272389       
    TIME     : [ 0]: 63.257 mins  [++]: 14.530 mins  [--]: 16.616 mins  [+-]: 14.498 mins  [-+]: 16.666 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -3.05405 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:   9.68%      [++]:   9.65%      [--]:   9.76%      [+-]:   9.79%      [-+]:   9.53%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] :37.6/79032.3 Hz   T2[ 0] : 0.0/12.8 Hz   T3[ 0] :42.5/1147.8 Hz   T4[ 0] : 0.0/37.4 Hz   T5[ 0] :37.6/37.6 Hz   T6[ 0] :164.4/16438.3 Hz   T7[ 0] : 0.0/12.9 Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] :35.8/75131.4 Hz   T2[++] : 0.0/12.7 Hz   T3[++] :40.5/1094.2 Hz   T4[++] : 0.0/35.9 Hz   T5[++] :36.1/36.1 Hz   T6[++] :156.3/15629.6 Hz   T7[++] : 0.0/12.7 Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] :39.1/82176.9 Hz   T2[--] : 0.0/12.7 Hz   T3[--] :44.1/1189.4 Hz   T4[--] : 0.0/38.6 Hz   T5[--] :38.5/38.5 Hz   T6[--] :171.1/17108.6 Hz   T7[--] : 0.0/12.8 Hz   T8[--] :10.2/1024.0 Hz   
    T1[+-] :35.9/75359.1 Hz   T2[+-] : 0.0/12.8 Hz   T3[+-] :40.6/1097.1 Hz   T4[+-] : 0.0/35.9 Hz   T5[+-] :36.6/36.6 Hz   T6[+-] :156.6/15664.5 Hz   T7[+-] : 0.0/13.0 Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] :39.0/81996.8 Hz   T2[-+] : 0.0/12.8 Hz   T3[-+] :44.1/1189.5 Hz   T4[-+] : 0.0/38.5 Hz   T5[-+] :38.8/38.8 Hz   T6[-+] :170.5/17049.2 Hz   T7[-+] : 0.0/12.9 Hz   T8[-+] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] : 142838/299961739  T2[ 0] :      0/48406    T3[ 0] : 161343/4356270  T4[ 0] :      0/141834   T5[ 0] : 142871/142871   T6[ 0] : 623904/62390420  T7[ 0] :      0/48884    T8[ 0] :  38865/3886524  
    T1[++] :  31191/65501382  T2[++] :      0/11038    T3[++] :  35332/953973   T4[++] :      0/31342    T5[++] :  31487/31487    T6[++] : 136262/13626284  T7[++] :      0/11109    T8[++] :   8927/892748   
    T1[--] :  39013/81927393  T2[--] :      0/12692    T3[--] :  43919/1185828  T4[--] :      0/38469    T5[--] :  38389/38389    T6[--] : 170566/17056665  T7[--] :      0/12791    T8[--] :  10208/1020891  
    T1[+-] :  31216/65554443  T2[+-] :      0/11161    T3[+-] :  35348/954400   T4[+-] :      0/31240    T5[+-] :  31850/31850    T6[+-] : 136264/13626475  T7[+-] :      0/11289    T8[+-] :   8907/890772   
    T1[-+] :  39045/81995656  T2[-+] :      0/12809    T3[-+] :  44053/1189435  T4[-+] :      0/38492    T5[-+] :  38798/38798    T6[-+] : 170489/17048968  T7[-+] :      0/12869    T8[-+] :  10239/1023986  
    
    AVERAGE CURRENT
    BCM x1 : 10.1865uA  BCM x3 : 10.1864uA  BCM x10: 9.5934 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :    123.6 ppm     BCM u3 :   -56.67 ppm     BCM u10:   -66.95 ppm     
    BCM d1 :    54.31 ppm     BCM d3 :    642.8 ppm     BCM d10:    92.69 ppm     
    
    Target -
    BCM u1 :    67.48 ppm     BCM u3 :    102.5 ppm     BCM u10:    91.32 ppm     
    BCM d1 :    154.1 ppm     BCM d3 :     98.1 ppm     BCM d10:    198.2 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:0.03907        BCM u3 [ 0]:0.03906        BCM u10[ 0]:0.03455        
    BCM u1 [++]:0.008551       BCM u3 [++]:0.008541       BCM u10[++]:0.007555       
    BCM u1 [--]:0.01066        BCM u3 [--]:0.01066        BCM u10[--]:0.009433       
    BCM u1 [+-]:0.008549       BCM u3 [+-]:0.008542       BCM u10[+-]:0.007556       
    BCM u1 [-+]:0.01066        BCM u3 [-+]:0.01066        BCM u10[-+]:0.009435       
    
    BCM d1 [ 0]:0.03825        BCM d3 [ 0]:0.03827        BCM d10[ 0]:0.03827        
    BCM d1 [++]:0.008365       BCM d3 [++]:0.008378       BCM d10[++]:0.008369       
    BCM d1 [--]:0.01044        BCM d3 [--]:0.01045        BCM d10[--]:0.01045        
    BCM d1 [+-]:0.008364       BCM d3 [+-]:0.008367       BCM d10[+-]:0.008368       
    BCM d1 [-+]:0.01044        BCM d3 [-+]:0.01045        BCM d10[-+]:0.01045        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4075 at Sun Nov 30 22:35:27 EST 2008
    
    Wien angle : 31.1993
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 2.35006
    Left Arm arm angle : 16.0026
    HALLA:p : 5892.07
    HALLA:dpp : 2.86843e-06
    Tiefenbach Hall A energy : 5892.07
    Left Arm Top VDC Current : -2.14844
    Left Arm Bottom VDC Current : 1.75781
    -----
    Left Arm Q1 momentum : 2.35042
    Left Arm Q1 power supply : 1768.29
    Left Arm Q1 gauss meter : -0.14992
    Left Arm Q2 gauss meter : 0.5322
    Left Arm Q2 power supply current : 1011.99
    Left Arm Q2 momentum : 2.35019
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 804.503
    Left Arm D1 momentum : 2.35006
    Left Arm D1 NMR : 0.869672
    Left Arm Q3 gauss meter : -0.47198
    Left Arm Q3 power supply current : 935.554
    Left Arm Q3 momentum : 2.34994
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 710
    BigBite magnet current readback : 706.569
    BigBite Gaussmeter readback : 1.2138
    -----
    Average current of the two cavities : 11.7378
    Current on Unser monitor : 4.13698
    Current on Upstream bcm : 11.7466
    Current on Downstream bcm : 11.7291
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 11.8173
    Hall C Current : 3.20189
    MBSY1c magnet current (amp) : 246.901
    MBSY1c Bdl : 1.47358e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 5892.07
    Hall A momentum orbit correction (dpp) : 2.86843e-06
    Hall A setup momentum (MMSHLAE) : 5900.64
    Hall A energy (halla_MeV) : 5892.07
    Hall C energy (hallc_MeV) : 5904.21
    Delta(E)/E width (MV_AI_DXWID) : 2.62787
    IPM1C12.XPOS : 0.0100649
    IPM1H04A.XPOS : 0.18456
    IPM1H04A.YPOS : 1.57578
    IPM1H04B.XPOS : -1.49848
    IPM1H04B.YPOS : 1.19922
    -----
    HacL_HPE1313A:0_Ch58 : -0.182617
    HacL_HPE1313A:0_Ch55 : 23.8281
    HacL_HPE1313A:0_Ch54 : 0.0825195
    Left Arm Angle Vernier : 31.5
    Left Arm Scattering Angle : 16.0026
    Left VDC -DISC LVL Top : 3.89502
    Left VDC -DISC LVL Bottom : 3.95752
    Left VDC -DISC LVL Voltage1 : 4.97266
    Left VDC -DISC LVL Voltage2 : -5.06396
    -----
    Wien angle : 31.1993
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 713.25
    Wien field : 20.72
    Laser attenuation Hall A : 207
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    RICH Vmon 16 : 2204.2
    RICH Imon 16 : CAENdatC --- Invalid channel name 1M2Ch16.NLK --- Invalid channel name
    RICH Vmon 17 : 201
    RICH Imon 17 : 0
    RICH Radiator Oxygen : -1.85547
    RICH Radiator Moisture : 325.293
    RICH Radiator Pressure : 9.75293
    RICH Condensor temperature : -9.13281
    RICH Gas Oxygen : 4.98047
    RICH Gas Moisture : 11.6211
    RICH Argon Flow : 0.488281
    RICH Methane Flow : 1547.95
    RICH A Volts : 3.80859
    RICH B Volts : 3.88135
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.0673053
    SLI Energy spread *10^5 : 1.68263
    SLI x position : 1.43106
    SLI vert. size mm : 0.0809021
    SLI y position : 1.65258
    -----
    Polarized 3He Target
    RTD1 (upstream) : 39.9414
    RTD2 : 56.3965
    RTD3 : 156.816
    RTD4 : 78.6719
    RTD5 (downstream) : 42.8418
    RTD6 (pump cell up) : 244.277
    RTD7 (pump cell down) : 257.344
    HacAi_hpchan7: Temp at Ref. Cell : 38.6035
    HacAi_hpchan8: Temp at Ref. Cell : 56.1426
    HacAi_hpchan9: Temp at Ref. Cell : 39.0332
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -9.37
    Oven Air Flow : 230.2
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : 230.1
    HacOMEGA_SP1 : 230
    HacOMEGA_PROP1 : 300
    HacOMEGA_RST1 : 3000
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 0
    CLASER_TEMP : 0
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 6
    CLASER3_TEMP : 23
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP : 0
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 0
    CLASER5_TEMP : 0
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 0
    CLASER6_TEMP : 0
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0001
    ntc1_temp : 26.0385
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.003
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9981
    ntc3_temp : 25.0313
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : -4.621
    DDM45_2disp1_read : 6.233
    DDM45_3disp1_read : 6.233
    ----
    haPolHe3_Spin_State : -1
    haPolHe3_Flip_Sequence_ID : 269
    haPolHe3_Flip_Count : 142
    haPolHe3_EPR_ID : 11281520
    haPolHe3_EPR_POL : 53.8739
    haPolHe3_Last_Flip_Start : 22:21:29 11/30/2008nit
    haPolHe3_Last_Flip_End : 22:21:35 11/30/2008nit
    haPolHe3_FLIP_NMR_PHASE : -0.942814
    haPolHe3_FLIP_NMR_Mag : 22.3329
    haPolHe3_FLIP_NMR_Pol : 65.1497
    HaGenTargSpin1 : enabled
    HaGenTargSpin2 : disabled
    HaGenTargPos : -9.37
    ----