    Log entry time 19:44:13 on December 21, 2008

    Entry number 254309

    keyword=End_of_Run_4667
    ****************************
     Run Number: 4667
     End of Run Comment:
    Run_type=Production,target_type=Polarized 3He,targetpol_poldir=Vertical,targetpol_pol=68,beam_e0=5.892,beam_raster=on,leftarm_p=+2.35,leftarm_theta=16,leftarm_sieve=out,bbarm_i=710,bbarm_theta=30,bbarm_sieve=out,bbarm_zoff=0,comment_text=production 13.1uA, HAPPEX run=30614
     
    
    PRESCALE FACTORS:ps1=2000   ps2=16777215   ps3=67   ps4=16777215   ps5=1   ps6=100   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 998260       [++]: 209241       [--]: 281818       [+-]: 209256       [-+]: 282519       
    TIME     : [ 0]: 59.351 mins  [++]: 12.445 mins  [--]: 16.780 mins  [+-]: 12.410 mins  [-+]: 16.839 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -3.43892 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:  12.67%      [++]:  13.40%      [--]:  12.21%      [+-]:  13.37%      [-+]:  12.14%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] :40.7/81476.5 Hz   T2[ 0] : 0.0/1.1  Hz   T3[ 0] :40.2/2694.0 Hz   T4[ 0] : 0.0/91.8 Hz   T5[ 0] :72.9/72.9 Hz   T6[ 0] :158.1/15807.7 Hz   T7[ 0] : 0.0/12.8 Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] :41.0/81941.9 Hz   T2[++] : 0.0/1.1  Hz   T3[++] :40.9/2738.1 Hz   T4[++] : 0.0/93.0 Hz   T5[++] :73.9/73.9 Hz   T6[++] :158.8/15881.8 Hz   T7[++] : 0.0/12.8 Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] :40.5/81065.7 Hz   T2[--] : 0.0/1.1  Hz   T3[--] :39.7/2660.4 Hz   T4[--] : 0.0/90.9 Hz   T5[--] :72.0/72.0 Hz   T6[--] :157.6/15757.5 Hz   T7[--] : 0.0/12.9 Hz   T8[--] :10.2/1024.0 Hz   
    T1[+-] :41.1/82170.1 Hz   T2[+-] : 0.0/1.2  Hz   T3[+-] :41.0/2745.5 Hz   T4[+-] : 0.0/93.2 Hz   T5[+-] :74.2/74.2 Hz   T6[+-] :159.2/15917.7 Hz   T7[+-] : 0.0/12.8 Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] :40.4/80804.0 Hz   T2[-+] : 0.0/1.0  Hz   T3[-+] :39.5/2649.8 Hz   T4[-+] : 0.0/90.4 Hz   T5[-+] :72.1/72.1 Hz   T6[-+] :157.2/15719.7 Hz   T7[-+] : 0.0/12.7 Hz   T8[-+] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] : 145072/290144814  T2[ 0] :      0/3837     T3[ 0] : 143185/9593461  T4[ 0] :      0/326821   T5[ 0] : 259762/259762   T6[ 0] : 562925/56292522  T7[ 0] :      0/45708    T8[ 0] :  36465/3646553  
    T1[++] :  30592/61184101  T2[++] :      0/817      T3[++] :  30515/2044506  T4[++] :      0/69444    T5[++] :  55197/55197    T6[++] : 118585/11858576  T7[++] :      0/9575     T8[++] :   7645/764597   
    T1[--] :  40808/81617530  T2[--] :      0/1064     T3[--] :  39977/2678460  T4[--] :      0/91540    T5[--] :  72481/72481    T6[--] : 158647/15864728  T7[--] :      0/13022    T8[--] :  10309/1030970  
    T1[+-] :  30590/61181821  T2[+-] :      0/869      T3[+-] :  30510/2044227  T4[+-] :      0/69361    T5[+-] :  55221/55221    T6[+-] : 118519/11851936  T7[+-] :      0/9530     T8[+-] :   7624/762445   
    T1[-+] :  40819/81638948  T2[-+] :      0/1022     T3[-+] :  39957/2677144  T4[-+] :      0/91362    T5[-+] :  72840/72840    T6[-+] : 158821/15882149  T7[-+] :      0/12831    T8[-+] :  10345/1034581  
    
    AVERAGE CURRENT
    BCM x1 : 11.8550uA  BCM x3 : 11.8519uA  BCM x10: 11.1637uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :    188.1 ppm     BCM u3 :    14.67 ppm     BCM u10:    6.947 ppm     
    BCM d1 :    124.7 ppm     BCM d3 :    826.3 ppm     BCM d10:    180.1 ppm     
    
    Target -
    BCM u1 :    76.61 ppm     BCM u3 :      112 ppm     BCM u10:    105.3 ppm     
    BCM d1 :    216.3 ppm     BCM d3 :    111.7 ppm     BCM d10:    214.4 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:0.04252        BCM u3 [ 0]:0.04251        BCM u10[ 0]:0.0376         
    BCM u1 [++]:0.00902        BCM u3 [++]:0.009016       BCM u10[++]:0.007975       
    BCM u1 [--]:0.01191        BCM u3 [--]:0.0119         BCM u10[--]:0.01053        
    BCM u1 [+-]:0.009017       BCM u3 [+-]:0.009016       BCM u10[+-]:0.007975       
    BCM u1 [-+]:0.01191        BCM u3 [-+]:0.01191        BCM u10[-+]:0.01053        
    
    BCM d1 [ 0]:0.04191        BCM d3 [ 0]:0.0419         BCM d10[ 0]:0.04191        
    BCM d1 [++]:0.008891       BCM d3 [++]:0.008904       BCM d10[++]:0.008895       
    BCM d1 [--]:0.01173        BCM d3 [--]:0.01173        BCM d10[--]:0.01174        
    BCM d1 [+-]:0.008889       BCM d3 [+-]:0.008889       BCM d10[+-]:0.008892       
    BCM d1 [-+]:0.01174        BCM d3 [-+]:0.01174        BCM d10[-+]:0.01174        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4667 at Sun Dec 21 19:43:55 EST 2008
    
    Wien angle : 31.1993
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 2.34999
    Left Arm arm angle : 16.0026
    HALLA:p : 5892.06
    HALLA:dpp : 3.46652e-07
    Tiefenbach Hall A energy : 5892.06
    Left Arm Top VDC Current : -0.488281
    Left Arm Bottom VDC Current : 1.9043
    -----
    Left Arm Q1 momentum : 2.35042
    Left Arm Q1 power supply : 1768.29
    Left Arm Q1 gauss meter : 0.1505
    Left Arm Q2 gauss meter : -0.5314
    Left Arm Q2 power supply current : 1011.83
    Left Arm Q2 momentum : 2.34982
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 804.855
    Left Arm D1 momentum : 2.34999
    Left Arm D1 NMR : 0.869645
    Left Arm Q3 gauss meter : 0.47296
    Left Arm Q3 power supply current : 935.408
    Left Arm Q3 momentum : 2.34957
    Left Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 710
    BigBite magnet current readback : 706.569
    BigBite Gaussmeter readback : 1.2135
    -----
    Average current of the two cavities : 13.3488
    Current on Unser monitor : 5.42631
    Current on Upstream bcm : 13.3457
    Current on Downstream bcm : 13.3519
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 13.4995
    Hall C Current : 0.506474
    MBSY1c magnet current (amp) : 246.901
    MBSY1c Bdl : 1.47358e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 5892.07
    Hall A momentum orbit correction (dpp) : 2.00425e-06
    Hall A setup momentum (MMSHLAE) : 5900.64
    Hall A energy (halla_MeV) : 5892.07
    Hall C energy (hallc_MeV) : 4730
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.0071176
    IPM1H04A.XPOS : 0.175846
    IPM1H04A.YPOS : 1.74129
    IPM1H04B.XPOS : -1.55741
    IPM1H04B.YPOS : 1.20167
    -----
    HacL_HPE1313A:0_Ch58 : -0.181152
    HacL_HPE1313A:0_Ch55 : 24.3164
    HacL_HPE1313A:0_Ch54 : 0.0830078
    Left Arm Angle Vernier : 31.5
    Left Arm Scattering Angle : 16.0026
    Left VDC -DISC LVL Top : 3.89697
    Left VDC -DISC LVL Bottom : 3.96436
    Left VDC -DISC LVL Voltage1 : 4.97363
    Left VDC -DISC LVL Voltage2 : -5.06201
    -----
    Wien angle : 31.1993
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 713.25
    Wien field : 20.72
    Laser attenuation Hall A : 146
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    RICH Vmon 16 : 2203.8
    RICH Imon 16 : CAENdatC --- Invalid channel name 1M2Ch16.NLK --- Invalid channel name
    RICH Vmon 17 : 200.8
    RICH Imon 17 : 0.01
    RICH Radiator Oxygen : -1.07422
    RICH Radiator Moisture : 1245.9
    RICH Radiator Pressure : 9.73145
    RICH Condensor temperature : -10.0117
    RICH Gas Oxygen : 57.8125
    RICH Gas Moisture : 12.3047
    RICH Argon Flow : 0.585938
    RICH Methane Flow : 1549.8
    RICH A Volts : 3.80664
    RICH B Volts : 3.8833
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.41615
    SLI vert. size mm : 0
    SLI y position : 2.77183
    -----
    Polarized 3He Target
    RTD1 (upstream) : 39.4238
    RTD2 : 59.8926
    RTD3 : 144.238
    RTD4 : 76.1426
    RTD5 (downstream) : 41.5137
    RTD6 (pump cell up) : 240.879
    RTD7 (pump cell down) : 246.445
    HacAi_hpchan7: Temp at Ref. Cell : 38.418
    HacAi_hpchan8: Temp at Ref. Cell : 51.9727
    HacAi_hpchan9: Temp at Ref. Cell : 38.8281
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -9.37
    Oven Air Flow : 229.9
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 200
    HacOMEGA_READ : 229.8
    HacOMEGA_SP1 : 230
    HacOMEGA_PROP1 : 300
    HacOMEGA_RST1 : 600
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 0
    CLASER_TEMP : 0
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 6
    CLASER3_TEMP : 23
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP : 0
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 0
    CLASER5_TEMP : 0
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 0
    CLASER6_TEMP : 0
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0021
    ntc1_temp : 26.0367
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.002
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9971
    ntc3_temp : 25.0278
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : -0.357
    DDM45_2disp1_read : 14.0927
    DDM45_3disp1_read : 0.329
    ----
    haPolHe3_Spin_State : -1
    haPolHe3_Flip_Sequence_ID : 278
    haPolHe3_Flip_Count : 183
    haPolHe3_EPR_ID : 12131807
    haPolHe3_EPR_POL : 63.1728
    haPolHe3_Last_Flip_Start : 19:29:37 12/21/2008abled
    haPolHe3_Last_Flip_End : 19:29:42 12/21/2008abled
    haPolHe3_FLIP_NMR_PHASE : 3.82168
    haPolHe3_FLIP_NMR_Mag : 13.0663
    haPolHe3_FLIP_NMR_Pol : 66.1948
    HaGenTargSpin1 : enabled
    HaGenTargSpin2 : disabled
    HaGenTargPos : -9.37
    ----