Log entry time 16:27:22 on December 23, 2008
Entry number 254487
keyword=End_of_Run_20237
****************************
Run Number: 20237
End of Run Comment:
Run_type=Check out,target_type=Empty,beam_e0=5.9,beam_raster=off,beam_halfwaveplate=out,rightarm_p=0.6,rightarm_theta=-90,rightarm_colli=out,comment_text=
****************************
End-of-run EPICS data for Run Number 20237 at Tue Dec 23 16:26:47 EST 2008
Wien angle : 31.3998
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 0.00245748
Left Arm arm angle : 16.0026
Right Arm D1 momentum : 0.0116589
Right Arm arm angle : 0.197
HALLA:p : 5892.06
HALLA:dpp : 0
Tiefenbach Hall A energy : 5892.06
Left Arm Top VDC Current : -2.00195
Left Arm Bottom VDC Current : 3.66211
----
Left Arm Q1 momentum : 0.00178211
Left Arm Q1 power supply : 0
Left Arm Q1 gauss meter : 0.0004229
Left Arm Q2 gauss meter : -0.0008047
Left Arm Q2 power supply current : 0.00452251
Left Arm Q2 momentum : 0.00426787
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -1.37023
Left Arm D1 momentum : 0.00246973
Left Arm D1 NMR : 1.07439
Left Arm Q3 gauss meter : 0.00152222
Left Arm Q3 power supply current : -0.0115592
Left Arm Q3 momentum : -2.90346e-05
Left Arm Q3 power supply polarity : disabled
----
Right Arm Q1 momentum : 0.000307529
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -2.78e-05
Right Arm Q2 power supply current : -0.0146454
Right Arm Q2 momentum : -3.46227e-05
Right Arm Q2 gauss meter : -0.0001377
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 2.02143
Right Arm D1 momentum : 0.0116725
Right Arm D1 NMR : 0.161756
Right Arm Q3 power supply current : -451.01
Right Arm Q3 momentum : -1.13343
Right Arm Q3 gauss meter : -0.0002598
Right Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 710
BigBite magnet current readback : 706.553
BigBite magnet magnet probe : 1.2138
-----
Average current of the two cavities : 0.0319129
Current on Unser monitor : -8.29348
Current on Upstream bcm : 0.0475946
Current on Downstream bcm : 0.0162313
Upstream Cavity Coefficient : 48.345
Downstream Cavity Coefficient : 47.773
Current on IBC0L02 (source) : 0.00502488
Hall C Current : 0
MBSY1c magnet current (amp) : 2
MBSY1c Bdl : 1.47358e+06
Hall A momentum (Tiefenbach) (HALLA:p) : 5892.06
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 5900.64
Hall A energy (halla_MeV) : 5892.06
Hall C energy (hallc_MeV) : 5904.21
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Left Arm Collimator : 0.000146484
HacL_HPE1313A:0_Ch58 : -0.188965
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : 0.0883789
-----
Right Arm Collimator : -0.00893555
HacR_HPE1313A:0_Ch58 : -0.544922
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.969238
-----
Wien angle : 31.3998
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 3.18799
Wien field : 20.854
Laser attenuation Hall A : 80
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 0
Beam Half-wave plate (off=out) : OUT
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
Target OTR x-position : hlat:MV_AI_DXPOS --- Invalid channel name
Target OTR y-position : hlat:MV_AI_DYPOS --- Invalid channel name
Target OTR x-width : hlat:MV_AI_DXWID --- Invalid channel name
Target OTR y-width : hlat:MV_AI_DYWID --- Invalid channel name
Target OTR data valid flag : hlat:DataValid --- Invalid channel name
Target OTR In/Out : hlat:DataReason --- Invalid channel name
Arc OTR x-position : -5.54417
Arc OTR y-position : -1.36317
Arc OTR x-width : 5.82218
Arc OTR y-width : 5.26159
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 1.44596
SLI vert. size mm : 0
SLI y position : 0.495775
-----
Target : Clear
Vacuum Pressure : 1e-10
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
Encoder position : 0
Target type : 0
temperature loop 1(1) : 0
temperature loop 1(2) : 0
temperature loop 1(3) : 0
Heat exchange He2 : 0
temperature loop 2(1) : 0
temperature loop 2(2) : 0
temperature loop 2(3) : 0
Heat exchange D2 : 0
HPH He loop 1 : 0.0540192
HPH He loop 2 : 0.00356948