    Log entry time 21:45:32 on February 11, 2009

    Entry number 260553

    keyword=End_of_Run_20135
    ****************************
     Run Number: 20135
     End of Run Comment:
    Run_type=Test,target_type=No Target,targetpol_poldir=Transverse-in-plane,targetpol_pol=45.9,beam_e0=5.9,beam_raster=on,beam_halfwaveplate=in,leftarm_p=1.6,leftarm_theta=45,leftarm_sieve=out,bbarm_i=710,bbarm_theta=30,bbarm_sieve=out,bbarm_zoff=,comment_text=Check left HRS buffering
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=16777215   ps3=1   ps4=1   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [ 0]: 16780        [++]: 8244         [--]: 8273         [+-]: 8244         [-+]: 8273         
    TIME     : [ 0]: 11.573 mins  [++]: 5.702 mins  [--]: 5.700 mins  [+-]: 5.702 mins  [-+]: 5.700 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =      -695.76123 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:   1.05%      [++]:   1.11%      [--]:   1.02%      [+-]:   1.07%      [-+]:   1.13%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] : 0.0/0.0  Hz   T2[ 0] : 0.0/0.0  Hz   T3[ 0] :14.8/14.8 Hz   T4[ 0] : 9.6/9.6  Hz   T5[ 0] : 0.0/0.0  Hz   T6[ 0] : 0.0/0.0  Hz   T7[ 0] : 0.0/0.0  Hz   T8[ 0] : 0.0/1024.0 Hz   
    T1[++] : 0.0/0.0  Hz   T2[++] : 0.0/0.0  Hz   T3[++] :14.8/14.8 Hz   T4[++] : 9.6/9.6  Hz   T5[++] : 0.0/0.0  Hz   T6[++] : 0.0/0.0  Hz   T7[++] : 0.0/0.0  Hz   T8[++] : 0.0/1024.0 Hz   
    T1[--] : 0.0/0.0  Hz   T2[--] : 0.0/0.0  Hz   T3[--] :14.9/14.9 Hz   T4[--] : 9.5/9.5  Hz   T5[--] : 0.0/0.0  Hz   T6[--] : 0.0/0.0  Hz   T7[--] : 0.0/0.0  Hz   T8[--] : 0.0/1024.0 Hz   
    T1[+-] : 0.0/0.0  Hz   T2[+-] : 0.0/0.0  Hz   T3[+-] :14.8/14.8 Hz   T4[+-] : 9.6/9.6  Hz   T5[+-] : 0.0/0.0  Hz   T6[+-] : 0.0/0.0  Hz   T7[+-] : 0.0/0.0  Hz   T8[+-] : 0.0/1024.0 Hz   
    T1[-+] : 0.0/0.0  Hz   T2[-+] : 0.0/0.0  Hz   T3[-+] :14.9/14.9 Hz   T4[-+] : 9.6/9.6  Hz   T5[-+] : 0.0/0.0  Hz   T6[-+] : 0.0/0.0  Hz   T7[-+] : 0.0/0.0  Hz   T8[-+] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] :      0/0        T2[ 0] :      0/0        T3[ 0] :  10303/10303    T4[ 0] :   6646/6646     T5[ 0] :      0/0        T6[ 0] :      0/0        T7[ 0] :      0/0        T8[ 0] :     10/711051   
    T1[++] :      0/0        T2[++] :      0/0        T3[++] :   5050/5050     T4[++] :   3282/3282     T5[++] :      0/0        T6[++] :      0/0        T7[++] :      0/0        T8[++] :      5/350322   
    T1[--] :      0/0        T2[--] :      0/0        T3[--] :   5096/5096     T4[--] :   3258/3258     T5[--] :      0/0        T6[--] :      0/0        T7[--] :      0/0        T8[--] :      5/350221   
    T1[+-] :      0/0        T2[+-] :      0/0        T3[+-] :   5050/5050     T4[+-] :   3279/3279     T5[+-] :      0/0        T6[+-] :      0/0        T7[+-] :      0/0        T8[+-] :      5/350319   
    T1[-+] :      0/0        T2[-+] :      0/0        T3[-+] :   5096/5096     T4[-+] :   3267/3267     T5[-+] :      0/0        T6[-+] :      0/0        T7[-+] :      0/0        T8[-+] :      5/350231   
    
    AVERAGE CURRENT
    BCM x1 : 0.0116 uA  BCM x3 : 0.0091 uA  BCM x10: 0.0203 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :    1E+39 ppm     BCM u3 :    1E+39 ppm     BCM u10:        0 ppm     
    BCM d1 :  0.01011 ppm     BCM d3 : -0.01675 ppm     BCM d10:        0 ppm     
    
    Target -
    BCM u1 :    1E+39 ppm     BCM u3 :    1E+39 ppm     BCM u10: -0.02165 ppm     
    BCM d1 :    9.083 ppm     BCM d3 :    8.485 ppm     BCM d10:    5.904 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:-3.888E-06     BCM u3 [ 0]:-5.525E-06     BCM u10[ 0]:9.387E-06      
    BCM u1 [++]:-1.92E-06      BCM u3 [++]:-2.729E-06     BCM u10[++]:4.63E-06       
    BCM u1 [--]:-1.911E-06     BCM u3 [--]:-2.717E-06     BCM u10[--]:4.62E-06       
    BCM u1 [+-]:-1.92E-06      BCM u3 [+-]:-2.729E-06     BCM u10[+-]:4.63E-06       
    BCM u1 [-+]:-1.911E-06     BCM u3 [-+]:-2.717E-06     BCM u10[-+]:4.62E-06       
    
    BCM d1 [ 0]:1.996E-05      BCM d3 [ 0]:1.811E-05      BCM d10[ 0]:1.886E-05      
    BCM d1 [++]:9.89E-06       BCM d3 [++]:8.953E-06      BCM d10[++]:9.299E-06      
    BCM d1 [--]:9.771E-06      BCM d3 [--]:8.874E-06      BCM d10[--]:9.265E-06      
    BCM d1 [+-]:9.89E-06       BCM d3 [+-]:8.953E-06      BCM d10[+-]:9.299E-06      
    BCM d1 [-+]:9.771E-06      BCM d3 [-+]:8.874E-06      BCM d10[-+]:9.265E-06      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 20135 at Wed Feb 11 21:45:19 EST 2009
    
    Wien angle : 22.9937
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0.6
    Left Arm arm angle : 44.9985
    HALLA:p : 5892.03
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 5892.03
    Left Arm Top VDC Current : -1.61133
    Left Arm Bottom VDC Current : -1.12305
    -----
    Left Arm Q1 momentum : 0.600062
    Left Arm Q1 power supply : 451.446
    Left Arm Q1 gauss meter : -0.03833
    Left Arm Q2 gauss meter : 0.13659
    Left Arm Q2 power supply current : 258.392
    Left Arm Q2 momentum : 0.600075
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 199.233
    Left Arm D1 momentum : 0.6
    Left Arm D1 NMR : 0.222238
    Left Arm Q3 gauss meter : -0.120889
    Left Arm Q3 power supply current : 238.859
    Left Arm Q3 momentum : 0.599969
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 710
    BigBite magnet current readback : 706.553
    BigBite Gaussmeter readback : 1.2137
    -----
    Average current of the two cavities : 0.0360543
    Current on Unser monitor : -7.27795
    Current on Upstream bcm : 0.0475114
    Current on Downstream bcm : 0.0245972
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 0.104142
    Hall C Current : 96.3975
    MBSY1c magnet current (amp) : 246.9
    MBSY1c Bdl : 1.47358e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 5892.03
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 5900.64
    Hall A energy (halla_MeV) : 5892.03
    Hall C energy (hallc_MeV) : 5890.43
    Delta(E)/E width (MV_AI_DXWID) : 0.132105
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    HacL_HPE1313A:0_Ch58 : -0.262695
    HacL_HPE1313A:0_Ch55 : 22.8027
    HacL_HPE1313A:0_Ch54 : -0.320312
    Left Arm Angle Vernier : 30.8
    Left Arm Scattering Angle : 44.9985
    Left VDC -DISC LVL Top : 3.896
    Left VDC -DISC LVL Bottom : 3.56299
    Left VDC -DISC LVL Voltage1 : 4.97412
    Left VDC -DISC LVL Voltage2 : -5.05664
    -----
    Wien angle : 22.9937
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 463.02
    Wien field : 12.889
    Laser attenuation Hall A : 106
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : 2.69282
    Target OTR y-position : -0.681506
    Target OTR x-width : 2.89609
    Target OTR y-width : 2.40998
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.82609
    SLI vert. size mm : 0
    SLI y position : 2.84695
    -----
    Polarized 3He Target
    RTD1 (upstream) : 48.7891
    RTD2 : 117.578
    RTD3 : 120.293
    RTD4 : 72.4512
    RTD5 (downstream) : 48.3496
    RTD6 (pump cell up) : 281.133
    RTD7 (pump cell down) : 247.266
    HacAi_hpchan7: Temp at Ref. Cell : 42.0508
    HacAi_hpchan8: Temp at Ref. Cell : 42.7539
    HacAi_hpchan9: Temp at Ref. Cell : 40.4785
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -2.25
    Oven Air Flow : 240
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 252
    HacOMEGA_READ : 239.7
    HacOMEGA_SP1 : 240
    HacOMEGA_PROP1 : 500
    HacOMEGA_RST1 : 180
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 34
    CLASER_TEMP : 14
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 0
    CLASER3_TEMP : 0
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP : 0
    -----
    CLASER5_STATE_MB : On
    CLASER5_RDCUR : 31
    CLASER5_TEMP : 19.2
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 0
    CLASER6_TEMP : 0
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 34.9971
    ntc1_temp : 26.0367
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : -9.9999
    ntc2_temp : -99.99
    nld2_lasouti : Disable
    ntc2_tecouti : Enable
    nld2_lascond : 512
    ----
    nld3_lasmdp : 35.9951
    ntc3_temp : 25.1028
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : 3.908
    DDM45_2disp1_read : 0.712066
    DDM45_3disp1_read : -5.531
    ----
    haPolHe3_Spin_State : 0
    haPolHe3_Flip_Sequence_ID : 36
    haPolHe3_Flip_Count : 0
    haPolHe3_EPR_ID : 0
    haPolHe3_EPR_POL : 0
    haPolHe3_Last_Flip_Start : 16:08:11 10/16/2008
    haPolHe3_Last_Flip_End : 19:00:00 12/31/1903
    haPolHe3_FLIP_NMR_PHASE : 0
    haPolHe3_FLIP_NMR_Mag : 0
    haPolHe3_FLIP_NMR_Pol : 45.1313
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : disabled
    HaGenTargPos : -2.25
    ----