Moller results


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name O. Glamazdin

    Log entry time 21:45:47 on February 11, 2009

    Entry number 260554

    keyword=Moller results

    Moller results on Feb 11 15:25-21:10

    Mini Spin Dance


    Preliminary results: not corrected for the beam energy fluctuations.
     #    Wien angle  beam     runs target Ptarget% Pbeam%
    1 30° 0.8 µA 13174-13175 5 8.03 81.5±0.2±2.0
    2 30° 0.8 µA 13176-13179 4 7.51 81.1±0.2±2.0
    Aver. 30° 0.8 µA 13174-13179 4,5 - 81.2±0.1±2.0
    1 20° 0.8 µA 13180-13181 5 8.03 72.6±0.2±2.0
    2 20° 0.8 µA 13182-13185 4 7.51 70.5±0.2±2.0
    Aver. 20° 0.8 µA 13180-13185 4,5 - 71.1±0.1±2.0
    1 23° 0.8 µA 13186-13187 5 8.03 73.2±0.2±2.0
    2 23° 0.8 µA 13189-13190 4 7.51 73.5±0.2±2.0
    Aver. 23° 0.8 µA 13186-13190 4,5 - 73.3±0.1±2.0

    Spin Dance Results

    The Wien filter angle 23° was choosen as an optimal for the Hall A and the Hall C beam polarization values.
    Hall A Moller results are presented in the chart attached.
    All results are preliminary only and have to be corrected on the beam energy fluctuation.

    A copy of this log entry has been emailed to: gen@jlab.org



    Figure 1



    Figure 2