Privacy and Security Notice

End_of_Run_1616


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 21:39:55 on February 19, 2009

    Entry number 262180

    keyword=End_of_Run_1616
    ****************************
     Run Number: 1616
     End of Run Comment:
    Run_type=Test,target_type=No Target,targetpol_poldir=Transverse-in-plane,targetpol_pol=62.84,beam_e0=5.892,beam_raster=on,beam_halfwaveplate=in,leftarm_p=1.42,leftarm_theta=45,leftarm_sieve=out,bbarm_i=710,bbarm_theta=45,bbarm_sieve=out,bbarm_zoff=0,comment_text=original binary eventlist for FADC, recompiled for other ROCS
    
    PRESCALE FACTORS:ps1=16777215   ps2=2   ps3=16777215   ps4=16777215   ps5=65535   ps6=100   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 47642        [++]: 23225        [--]: 23638        [+-]: 23638        [-+]: 23225        
    TIME     : [ 0]: 0.870 mins  [++]: 0.347 mins  [--]: 0.347 mins  [+-]: 0.347 mins  [-+]: 0.347 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         9.88022 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:  50.06%      [++]:  38.58%      [--]:  37.73%      [+-]:  37.73%      [-+]:  38.58%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] : 0.0/9573.6 Hz   T2[ 0] :1739.9/3479.9 Hz   T3[ 0] : 0.0/30.1 Hz   T4[ 0] : 0.0/30.8 Hz   T5[ 0] : 0.0/8.3  Hz   T6[ 0] :94.5/9450.1 Hz   T7[ 0] : 0.0/0.0  Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] : 0.0/9534.9 Hz   T2[++] :1727.4/3454.9 Hz   T3[++] : 0.0/30.2 Hz   T4[++] : 0.0/31.6 Hz   T5[++] : 0.0/8.0  Hz   T6[++] :94.1/9414.3 Hz   T7[++] : 0.0/0.0  Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] : 0.0/9555.3 Hz   T2[--] :1735.5/3471.0 Hz   T3[--] : 0.0/29.3 Hz   T4[--] : 0.0/31.7 Hz   T5[--] : 0.0/8.6  Hz   T6[--] :94.3/9436.6 Hz   T7[--] : 0.0/0.0  Hz   T8[--] :10.2/1024.0 Hz   
    T1[+-] : 0.0/9555.3 Hz   T2[+-] :1735.5/3471.0 Hz   T3[+-] : 0.0/29.3 Hz   T4[+-] : 0.0/31.7 Hz   T5[+-] : 0.0/8.6  Hz   T6[+-] :94.3/9436.6 Hz   T7[+-] : 0.0/0.0  Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] : 0.0/9534.9 Hz   T2[-+] :1727.4/3454.9 Hz   T3[-+] : 0.0/30.2 Hz   T4[-+] : 0.0/31.6 Hz   T5[-+] : 0.0/8.0  Hz   T6[-+] :94.1/9414.3 Hz   T7[-+] : 0.0/0.0  Hz   T8[-+] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] :      0/499866   T2[ 0] :  90847/181694   T3[ 0] :      0/1574     T4[ 0] :      0/1609     T5[ 0] :      0/433      T6[ 0] :   4934/493419   T7[ 0] :      0/0        T8[ 0] :    534/53466    
    T1[++] :      0/198696   T2[++] :  35998/71996    T3[++] :      0/629      T4[++] :      0/659      T5[++] :      0/166      T6[++] :   1961/196184   T7[++] :      0/0        T8[++] :    213/21339    
    T1[--] :      0/199009   T2[--] :  36146/72292    T3[--] :      0/611      T4[--] :      0/660      T5[--] :      0/180      T6[--] :   1965/196537   T7[--] :      0/0        T8[--] :    213/21327    
    T1[+-] :      0/199009   T2[+-] :  36146/72292    T3[+-] :      0/611      T4[+-] :      0/660      T5[+-] :      0/180      T6[+-] :   1965/196537   T7[+-] :      0/0        T8[+-] :    213/21327    
    T1[-+] :      0/198696   T2[-+] :  35998/71996    T3[-+] :      0/629      T4[-+] :      0/659      T5[-+] :      0/166      T6[-+] :   1961/196184   T7[-+] :      0/0        T8[-+] :    213/21339    
    
    AVERAGE CURRENT
    BCM x1 : 0.8097 uA  BCM x3 : 0.8079 uA  BCM x10: 0.7681 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :    553.3 ppm     BCM u3 :    343.3 ppm     BCM u10:    361.7 ppm     
    BCM d1 :     1017 ppm     BCM d3 :    439.7 ppm     BCM d10:    348.1 ppm     
    
    Target -
    BCM u1 :    553.3 ppm     BCM u3 :    343.3 ppm     BCM u10:    361.7 ppm     
    BCM d1 :     1017 ppm     BCM d3 :    439.7 ppm     BCM d10:    348.1 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:4.194E-05      BCM u3 [ 0]:4.18E-05       BCM u10[ 0]:3.775E-05      
    BCM u1 [++]:1.675E-05      BCM u3 [++]:1.668E-05      BCM u10[++]:1.507E-05      
    BCM u1 [--]:1.673E-05      BCM u3 [--]:1.667E-05      BCM u10[--]:1.506E-05      
    BCM u1 [+-]:1.673E-05      BCM u3 [+-]:1.667E-05      BCM u10[+-]:1.506E-05      
    BCM u1 [-+]:1.675E-05      BCM u3 [-+]:1.668E-05      BCM u10[-+]:1.507E-05      
    
    BCM d1 [ 0]:4.261E-05      BCM d3 [ 0]:4.257E-05      BCM d10[ 0]:4.246E-05      
    BCM d1 [++]:1.702E-05      BCM d3 [++]:1.7E-05        BCM d10[++]:1.695E-05      
    BCM d1 [--]:1.699E-05      BCM d3 [--]:1.698E-05      BCM d10[--]:1.694E-05      
    BCM d1 [+-]:1.699E-05      BCM d3 [+-]:1.698E-05      BCM d10[+-]:1.694E-05      
    BCM d1 [-+]:1.702E-05      BCM d3 [-+]:1.7E-05        BCM d10[-+]:1.695E-05      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1616 at Thu Feb 19 21:39:48 EST 2009
    
    Wien angle : 22.9937
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 1.42002
    Left Arm arm angle : 44.9985
    HALLA:p : 5891.7
    HALLA:dpp : -5.54704e-05
    Tiefenbach Hall A energy : 5891.8
    Left Arm Top VDC Current : 2.14844
    Left Arm Bottom VDC Current : 4.58984
    -----
    Left Arm Q1 momentum : 1.42026
    Left Arm Q1 power supply : 1068.51
    Left Arm Q1 gauss meter : -0.09057
    Left Arm Q2 gauss meter : 0.3222
    Left Arm Q2 power supply current : 611.621
    Left Arm Q2 momentum : 1.42039
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 468.509
    Left Arm D1 momentum : 1.42002
    Left Arm D1 NMR : 0.525587
    Left Arm Q3 gauss meter : -0.28523
    Left Arm Q3 power supply current : 565.203
    Left Arm Q3 momentum : 1.41968
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 710
    BigBite magnet current readback : 706.537
    BigBite Gaussmeter readback : 1.2135
    -----
    Average current of the two cavities : 0.80905
    Current on Unser monitor : -6.73891
    Current on Upstream bcm : 0.810919
    Current on Downstream bcm : 0.818664
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 0.832963
    Hall C Current : 25.9435
    MBSY1c magnet current (amp) : 246.9
    MBSY1c Bdl : 1.47358e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 5891.8
    Hall A momentum orbit correction (dpp) : -3.86727e-05
    Hall A setup momentum (MMSHLAE) : 5900.64
    Hall A energy (halla_MeV) : 5891.8
    Hall C energy (hallc_MeV) : 5895.25
    Delta(E)/E width (MV_AI_DXWID) : 1.00082
    IPM1C12.XPOS : 0.209866
    IPM1H04A.XPOS : 1.07901
    IPM1H04A.YPOS : 1.81014
    IPM1H04B.XPOS : 0.646274
    IPM1H04B.YPOS : 0.882998
    -----
    HacL_HPE1313A:0_Ch58 : -0.258301
    HacL_HPE1313A:0_Ch55 : 23.2422
    HacL_HPE1313A:0_Ch54 : -0.322266
    Left Arm Angle Vernier : 30.8
    Left Arm Scattering Angle : 44.9985
    Left VDC -DISC LVL Top : 3.89648
    Left VDC -DISC LVL Bottom : 3.89697
    Left VDC -DISC LVL Voltage1 : 4.97412
    Left VDC -DISC LVL Voltage2 : -5.05615
    -----
    Wien angle : 22.9937
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 463.02
    Wien field : 12.889
    Laser attenuation Hall A : 225
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : -4.93578
    Target OTR y-position : -1.32704
    Target OTR x-width : 5.78297
    Target OTR y-width : 4.96449
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.93043
    SLI vert. size mm : 0
    SLI y position : 1.02911
    -----
    Polarized 3He Target
    RTD1 (upstream) : 48.6914
    RTD2 : 119.238
    RTD3 : 122.334
    RTD4 : 71.1621
    RTD5 (downstream) : 48.6816
    RTD6 (pump cell up) : 279.668
    RTD7 (pump cell down) : 246.797
    HacAi_hpchan7: Temp at Ref. Cell : 42.2559
    HacAi_hpchan8: Temp at Ref. Cell : 42.8516
    HacAi_hpchan9: Temp at Ref. Cell : 40.7129
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -2.25
    Oven Air Flow : 240
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 252
    HacOMEGA_READ : 240.0
    HacOMEGA_SP1 : 240
    HacOMEGA_PROP1 : 500
    HacOMEGA_RST1 : 180
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 34
    CLASER_TEMP : 14
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 0
    CLASER3_TEMP : 0
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP : 0
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 31
    CLASER5_TEMP : 19.2
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 0
    CLASER6_TEMP : 0
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0031
    ntc1_temp : 26.0367
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.003
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9971
    ntc3_temp : 25
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : 3.898
    DDM45_2disp1_read : 0.712066
    DDM45_3disp1_read : -5.519
    ----
    haPolHe3_Spin_State : 0
    haPolHe3_Flip_Sequence_ID : 36
    haPolHe3_Flip_Count : 0
    haPolHe3_EPR_ID : 0
    haPolHe3_EPR_POL : 0
    haPolHe3_Last_Flip_Start : 16:08:11 10/16/2008
    haPolHe3_Last_Flip_End : 19:00:00 12/31/1903
    haPolHe3_FLIP_NMR_PHASE : 0
    haPolHe3_FLIP_NMR_Mag : 0
    haPolHe3_FLIP_NMR_Pol : 62.5909
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : disabled
    HaGenTargPos : -2.25
    ----