NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 20:30:37 on February 26, 2009
Entry number 263573
keyword=End_of_Run_1846
****************************
Run Number: 1846
End of Run Comment:
Run_type=Production,target_type=Reference Cell: N2,targetpol_poldir=Transverse-in-plane,targetpol_pol=62.3,beam_e0=5.892,beam_raster=on,beam_halfwaveplate=out,leftarm_p=1.51,leftarm_theta=45,leftarm_sieve=out,bbarm_i=710,bbarm_theta=45,bbarm_sieve=out,bbarm_zoff=0,comment_text=reference cell running production
PRESCALE FACTORS:ps1=16777215 ps2=2 ps3=16777215 ps4=16777215 ps5=65535 ps6=360 ps7=65535 ps8=100
EVENTS : [ 0]: 1262763 [++]: 621457 [--]: 622769 [+-]: 622769 [-+]: 621457
TIME : [ 0]: 6.792 mins [++]: 3.273 mins [--]: 3.272 mins [+-]: 3.272 mins [-+]: 3.273 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 8.55936 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [ 0]: 11.85% [++]: 10.94% [--]: 10.93% [+-]: 10.93% [-+]: 10.94%
TRIGGER RATES: PRES/REAL
T1[ 0] : 0.0/37623.5 Hz T2[ 0] :3408.7/6817.4 Hz T3[ 0] : 0.0/36.8 Hz T4[ 0] : 0.0/17.3 Hz T5[ 0] : 0.0/9.1 Hz T6[ 0] :106.2/38239.5 Hz T7[ 0] : 0.0/0.0 Hz T8[ 0] :10.2/1024.0 Hz
T1[++] : 0.0/38065.7 Hz T2[++] :3445.9/6891.9 Hz T3[++] : 0.0/37.6 Hz T4[++] : 0.0/17.4 Hz T5[++] : 0.0/9.2 Hz T6[++] :107.5/38688.1 Hz T7[++] : 0.0/0.0 Hz T8[++] :10.2/1024.0 Hz
T1[--] : 0.0/38090.6 Hz T2[--] :3453.7/6907.5 Hz T3[--] : 0.0/36.5 Hz T4[--] : 0.0/17.5 Hz T5[--] : 0.0/9.0 Hz T6[--] :107.5/38717.0 Hz T7[--] : 0.0/0.0 Hz T8[--] :10.2/1024.0 Hz
T1[+-] : 0.0/38090.7 Hz T2[+-] :3453.7/6907.5 Hz T3[+-] : 0.0/36.5 Hz T4[+-] : 0.0/17.5 Hz T5[+-] : 0.0/9.0 Hz T6[+-] :107.5/38717.0 Hz T7[+-] : 0.0/0.0 Hz T8[+-] :10.2/1024.0 Hz
T1[-+] : 0.0/38065.6 Hz T2[-+] :3445.9/6891.9 Hz T3[-+] : 0.0/37.6 Hz T4[-+] : 0.0/17.4 Hz T5[-+] : 0.0/9.2 Hz T6[-+] :107.5/38688.1 Hz T7[-+] : 0.0/0.0 Hz T8[-+] :10.2/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[ 0] : 0/15331375 T2[ 0] :1389020/2778040 T3[ 0] : 0/15010 T4[ 0] : 0/7040 T5[ 0] : 0/3700 T6[ 0] : 43284/15582385 T7[ 0] : 0/0 T8[ 0] : 4172/417274
T1[++] : 0/7474478 T2[++] : 676633/1353266 T3[++] : 0/7386 T4[++] : 0/3407 T5[++] : 0/1806 T6[++] : 21101/7596693 T7[++] : 0/0 T8[++] : 2010/201070
T1[--] : 0/7476995 T2[--] : 677952/1355905 T3[--] : 0/7170 T4[--] : 0/3442 T5[--] : 0/1764 T6[--] : 21110/7599951 T7[--] : 0/0 T8[--] : 2010/201006
T1[+-] : 0/7477011 T2[+-] : 677952/1355905 T3[+-] : 0/7170 T4[+-] : 0/3442 T5[+-] : 0/1764 T6[+-] : 21110/7599950 T7[+-] : 0/0 T8[+-] : 2010/201006
T1[-+] : 0/7474456 T2[-+] : 676633/1353266 T3[-+] : 0/7386 T4[-+] : 0/3407 T5[-+] : 0/1806 T6[-+] : 21101/7596693 T7[-+] : 0/0 T8[-+] : 2010/201070
AVERAGE CURRENT
BCM x1 : 5.0161 uA BCM x3 : 5.0146 uA BCM x10: 4.7277 uA
APPROXIMATE CURRENT ASYMMETRIES
Target +
BCM u1 : 109.8 ppm BCM u3 : 63.83 ppm BCM u10: 40.6 ppm
BCM d1 : 123.3 ppm BCM d3 : 56.56 ppm BCM d10: 42.53 ppm
Target -
BCM u1 : 109.8 ppm BCM u3 : 63.73 ppm BCM u10: 40.52 ppm
BCM d1 : 123.5 ppm BCM d3 : 56.56 ppm BCM d10: 42.46 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [ 0]:0.00206 BCM u3 [ 0]:0.002058 BCM u10[ 0]:0.001824
BCM u1 [++]:0.001004 BCM u3 [++]:0.001004 BCM u10[++]:0.0008893
BCM u1 [--]:0.001004 BCM u3 [--]:0.001003 BCM u10[--]:0.0008892
BCM u1 [+-]:0.001004 BCM u3 [+-]:0.001003 BCM u10[+-]:0.0008892
BCM u1 [-+]:0.001004 BCM u3 [-+]:0.001004 BCM u10[-+]:0.0008893
BCM d1 [ 0]:0.002028 BCM d3 [ 0]:0.002028 BCM d10[ 0]:0.002029
BCM d1 [++]:0.0009888 BCM d3 [++]:0.000989 BCM d10[++]:0.0009893
BCM d1 [--]:0.0009885 BCM d3 [--]:0.0009889 BCM d10[--]:0.0009892
BCM d1 [+-]:0.0009885 BCM d3 [+-]:0.0009889 BCM d10[+-]:0.0009892
BCM d1 [-+]:0.0009888 BCM d3 [-+]:0.000989 BCM d10[-+]:0.0009893
****************************
End-of-run EPICS data for Run Number 1846 at Thu Feb 26 20:30:29 EST 2009
Wien angle : 29.9923
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 1.50999
Left Arm arm angle : 44.9985
HALLA:p : 5892.04
HALLA:dpp : 0
Tiefenbach Hall A energy : 5892.04
Left Arm Top VDC Current : -1.9043
Left Arm Bottom VDC Current : 4.49219
-----
Left Arm Q1 momentum : 1.50999
Left Arm Q1 power supply : 1136.01
Left Arm Q1 gauss meter : -0.09639
Left Arm Q2 gauss meter : 0.3424
Left Arm Q2 power supply current : 650.194
Left Arm Q2 momentum : 1.50997
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 496.311
Left Arm D1 momentum : 1.50999
Left Arm D1 NMR : 0.558858
Left Arm Q3 gauss meter : -0.30334
Left Arm Q3 power supply current : 600.99
Left Arm Q3 momentum : 1.50958
Left Arm Q3 power supply polarity : disabled
-----
BigBite magnet current setpoint : 710
BigBite magnet current readback : 706.553
BigBite Gaussmeter readback : 1.2138
-----
Average current of the two cavities : 0.0422119
Current on Unser monitor : -9.26065
Current on Upstream bcm : 0.0534773
Current on Downstream bcm : 0.0309466
Upstream Cavity Coefficient : 48.345
Downstream Cavity Coefficient : 47.773
Current on IBC0L02 (source) : 0.00760546
Hall C Current : 30.143
MBSY1c magnet current (amp) : 246.9
MBSY1c Bdl : 1.47358e+06
Hall A momentum (Tiefenbach) (HALLA:p) : 5892.04
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 5900.64
Hall A energy (halla_MeV) : 5892.04
Hall C energy (hallc_MeV) : 4728
Delta(E)/E width (MV_AI_DXWID) : 1.10661
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
HacL_HPE1313A:0_Ch58 : -0.255371
HacL_HPE1313A:0_Ch55 : 22.9492
HacL_HPE1313A:0_Ch54 : -0.322754
Left Arm Angle Vernier : 30.8
Left Arm Scattering Angle : 44.9985
Left VDC -DISC LVL Top : 3.89648
Left VDC -DISC LVL Bottom : 3.72217
Left VDC -DISC LVL Voltage1 : 4.97461
Left VDC -DISC LVL Voltage2 : -5.05566
-----
Wien angle : 29.9923
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 604.61
Wien field : 16.812
Laser attenuation Hall A : 80
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 0
Beam Half-wave plate (off=out) : OUT
-----
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
Target OTR x-position : -2.23263
Target OTR y-position : -1.14927
Target OTR x-width : 2.52159
Target OTR y-width : 2.37545
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 0.827329
SLI vert. size mm : 0
SLI y position : 1.57746
-----
Polarized 3He Target
RTD1 (upstream) : 47.1582
RTD2 : 112.852
RTD3 : 115.498
RTD4 : 80.3906
RTD5 (downstream) : 45.6055
RTD6 (pump cell up) : 279.668
RTD7 (pump cell down) : 246.094
HacAi_hpchan7: Temp at Ref. Cell : 41.1719
HacAi_hpchan8: Temp at Ref. Cell : 42.1387
HacAi_hpchan9: Temp at Ref. Cell : 41.123
Reference Cell Gas Pressure (psi) : -277.5
Reference Cell System Vacuum (Torr) : -282
Cooling Jets Flow Rate : 0
Target position : -0.22
Oven Air Flow : 240.5
-----
HaGenTargBrake : enabled
HaGenTargBrake : enabled
HacOMEGA_AL1 : 252
HacOMEGA_READ : 240.5
HacOMEGA_SP1 : 240
HacOMEGA_PROP1 : 500
HacOMEGA_RST1 : 180
HacOMEGA_RATE : 0
-----
CLASER_STATE_MB : Disabled
CLASER_RDCUR : 34
CLASER_TEMP : 14
-----
CLASER2_STATE_MB : Disabled
CLASER2_RDCUR : 0
CLASER2_TEMP : 0
-----
CLASERAB_STATE_MB : Disabled
CLASERAB_GETCUR0 : 0
CLASERAB_GETCUR1 : 0
CLASERAB_GETTEMP0 : 0
CLASERAB_GETTEMP1 : 0
-----
CLASER3_STATE_MB : Disabled
CLASER3_RDCUR : 0
CLASER3_TEMP : 0
-----
CLASER4_STATE_MB : Disabled
CLASER4_RDCUR : 0
CLASER4_TEMP : 0
-----
CLASER5_STATE_MB : Disabled
CLASER5_RDCUR : 31
CLASER5_TEMP : 19.2
-----
CLASER6_STATE_MB : Disabled
CLASER6_RDCUR : 0
CLASER6_TEMP : 0
-----
CLASERAB2_STATE_M : Disabled
CLASERAB2_GETCUR0 : 0
CLASERAB2_GETCUR1 : 0
CLASERAB2_GETTEMP0 : 0
CLASERAB2_GETTEMP1 : 0
----
CLASERAB3_STATE_M : Disabled
CLASERAB3_GETCUR0 : 0
CLASERAB3_GETCUR1 : 0
CLASERAB3_GETTEMP0 : 0
CLASERAB3_GETTEMP1 : 0
----
nld1_lasmdp : 35.0021
ntc1_temp : 26.0367
nld1_lasouti : Enable
ntc1_tecouti : Enable
nld1_lascond : 1024
----
nld2_lasmdp : 34.002
ntc2_temp : 20
nld2_lasouti : Enable
ntc2_tecouti : Enable
nld2_lascond : 1024
----
nld3_lasmdp : 35.9961
ntc3_temp : 25.0261
nld3_lasouti : Enable
ntc3_tecouti : Enable
nld3_lascond : 1024
----
DDM45_1disp1_read : 3.903
DDM45_2disp1_read : 0.712066
DDM45_3disp1_read : -5.527
----
haPolHe3_Spin_State : -1
haPolHe3_Flip_Sequence_ID : 36
haPolHe3_Flip_Count : 0
haPolHe3_EPR_ID : 0
haPolHe3_EPR_POL : 0
haPolHe3_Last_Flip_Start : 16:08:11 10/16/2008
haPolHe3_Last_Flip_End : 19:00:00 12/31/1903
haPolHe3_FLIP_NMR_PHASE : 0
haPolHe3_FLIP_NMR_Mag : 0
haPolHe3_FLIP_NMR_Pol : 62.3594
HaGenTargSpin1 : disabled
HaGenTargSpin2 : disabled
HaGenTargPos : -0.22
----