Privacy and Security Notice

End_of_Run_1872


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 16:32:42 on February 27, 2009

    Entry number 263710

    keyword=End_of_Run_1872
    ****************************
     Run Number: 1872
     End of Run Comment:
    Run_type=Production,target_type=Polarized 3He,targetpol_poldir=Transverse-in-plane,targetpol_pol=62.57,beam_e0=5.892,beam_raster=on,beam_halfwaveplate=out,leftarm_p=1.51,leftarm_theta=45,leftarm_sieve=out,bbarm_i=710,bbarm_theta=45,bbarm_sieve=out,bbarm_zoff=0,comment_text=He3 production
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=2   ps3=16777215   ps4=16777215   ps5=65535   ps6=280   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 5425858      [++]: 2674904      [--]: 2671369      [+-]: 2671369      [-+]: 2674904      
    TIME     : [ 0]: 34.871 mins  [++]: 17.096 mins  [--]: 17.096 mins  [+-]: 17.096 mins  [-+]: 17.096 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         7.90619 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:  12.27%      [++]:  12.05%      [--]:  12.06%      [+-]:  12.06%      [-+]:  12.05%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] : 0.0/22544.5 Hz   T2[ 0] :2874.5/5749.0 Hz   T3[ 0] : 0.0/28.1 Hz   T4[ 0] : 0.0/21.8 Hz   T5[ 0] : 0.0/8.5  Hz   T6[ 0] :81.8/22908.3 Hz   T7[ 0] : 0.0/0.0  Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] : 0.0/22605.2 Hz   T2[++] :2883.1/5766.3 Hz   T3[++] : 0.0/28.2 Hz   T4[++] : 0.0/21.8 Hz   T5[++] : 0.0/8.4  Hz   T6[++] :82.0/22971.8 Hz   T7[++] : 0.0/0.0  Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] : 0.0/22590.4 Hz   T2[--] :2879.7/5759.5 Hz   T3[--] : 0.0/28.1 Hz   T4[--] : 0.0/22.0 Hz   T5[--] : 0.0/8.5  Hz   T6[--] :82.0/22954.3 Hz   T7[--] : 0.0/0.0  Hz   T8[--] :10.2/1024.0 Hz   
    T1[+-] : 0.0/22590.5 Hz   T2[+-] :2879.7/5759.5 Hz   T3[+-] : 0.0/28.1 Hz   T4[+-] : 0.0/22.0 Hz   T5[+-] : 0.0/8.5  Hz   T6[+-] :82.0/22954.3 Hz   T7[+-] : 0.0/0.0  Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] : 0.0/22605.2 Hz   T2[-+] :2883.1/5766.3 Hz   T3[-+] : 0.0/28.2 Hz   T4[-+] : 0.0/21.8 Hz   T5[-+] : 0.0/8.4  Hz   T6[-+] :82.0/22971.8 Hz   T7[-+] : 0.0/0.0  Hz   T8[-+] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] :      2/47168765  T2[ 0] :6014144/12028289  T3[ 0] :      0/58739    T4[ 0] :      0/45621    T5[ 0] :      0/17694    T6[ 0] : 171178/47929861  T7[ 0] :      0/0        T8[ 0] :  21424/2142464  
    T1[++] :      1/23187306  T2[++] :2957386/5914773  T3[++] :      0/28875    T4[++] :      0/22378    T5[++] :      0/8666     T6[++] :  84154/23563281  T7[++] :      0/0        T8[++] :  10503/1050368  
    T1[--] :      1/23172564  T2[--] :2953958/5907917  T3[--] :      0/28793    T4[--] :      0/22557    T5[--] :      0/8708     T6[--] :  84092/23545787  T7[--] :      0/0        T8[--] :  10503/1050388  
    T1[+-] :      1/23172616  T2[+-] :2953958/5907916  T3[+-] :      0/28793    T4[+-] :      0/22557    T5[+-] :      0/8708     T6[+-] :  84092/23545789  T7[+-] :      0/0        T8[+-] :  10503/1050388  
    T1[-+] :      1/23187256  T2[-+] :2957386/5914773  T3[-+] :      0/28875    T4[-+] :      0/22378    T5[-+] :      0/8666     T6[-+] :  84154/23563282  T7[-+] :      0/0        T8[-+] :  10503/1050368  
    
    AVERAGE CURRENT
    BCM x1 : 11.8388uA  BCM x3 : 11.8359uA  BCM x10: 11.1486uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :    -6.02 ppm     BCM u3 :   -25.31 ppm     BCM u10:   -33.12 ppm     
    BCM d1 :   -2.863 ppm     BCM d3 :   -25.73 ppm     BCM d10:   -32.02 ppm     
    
    Target -
    BCM u1 :    -6.06 ppm     BCM u3 :   -25.31 ppm     BCM u10:   -33.12 ppm     
    BCM d1 :   -2.904 ppm     BCM d3 :   -25.73 ppm     BCM d10:   -32.06 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:0.02502        BCM u3 [ 0]:0.02501        BCM u10[ 0]:0.02212        
    BCM u1 [++]:0.01229        BCM u3 [++]:0.01229        BCM u10[++]:0.01087        
    BCM u1 [--]:0.01229        BCM u3 [--]:0.01229        BCM u10[--]:0.01087        
    BCM u1 [+-]:0.01229        BCM u3 [+-]:0.01229        BCM u10[+-]:0.01087        
    BCM u1 [-+]:0.01229        BCM u3 [-+]:0.01229        BCM u10[-+]:0.01087        
    
    BCM d1 [ 0]:0.02452        BCM d3 [ 0]:0.02452        BCM d10[ 0]:0.02453        
    BCM d1 [++]:0.01205        BCM d3 [++]:0.01205        BCM d10[++]:0.01206        
    BCM d1 [--]:0.01205        BCM d3 [--]:0.01205        BCM d10[--]:0.01206        
    BCM d1 [+-]:0.01205        BCM d3 [+-]:0.01205        BCM d10[+-]:0.01206        
    BCM d1 [-+]:0.01205        BCM d3 [-+]:0.01205        BCM d10[-+]:0.01206        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1872 at Fri Feb 27 16:32:34 EST 2009
    
    Wien angle : 29.9923
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 1.50999
    Left Arm arm angle : 44.9985
    HALLA:p : 5892.04
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 5892.04
    Left Arm Top VDC Current : 1.17188
    Left Arm Bottom VDC Current : 2.7832
    -----
    Left Arm Q1 momentum : 1.50999
    Left Arm Q1 power supply : 1136.01
    Left Arm Q1 gauss meter : -0.09638
    Left Arm Q2 gauss meter : 0.3425
    Left Arm Q2 power supply current : 650.198
    Left Arm Q2 momentum : 1.50998
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 504.769
    Left Arm D1 momentum : 1.50999
    Left Arm D1 NMR : 0.558859
    Left Arm Q3 gauss meter : -0.30333
    Left Arm Q3 power supply current : 600.995
    Left Arm Q3 momentum : 1.50959
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 710
    BigBite magnet current readback : 706.553
    BigBite Gaussmeter readback : 1.2138
    -----
    Average current of the two cavities : 0.0427907
    Current on Unser monitor : -6.73162
    Current on Upstream bcm : 0.0547612
    Current on Downstream bcm : 0.0308203
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 0.00578463
    Hall C Current : 28.2645
    MBSY1c magnet current (amp) : 246.9
    MBSY1c Bdl : 1.47358e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 5892.04
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 5900.64
    Hall A energy (halla_MeV) : 5892.04
    Hall C energy (hallc_MeV) : 4728
    Delta(E)/E width (MV_AI_DXWID) : 1.12241
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    HacL_HPE1313A:0_Ch58 : -0.255371
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : -0.323242
    Left Arm Angle Vernier : 30.8
    Left Arm Scattering Angle : 44.9985
    Left VDC -DISC LVL Top : 3.89502
    Left VDC -DISC LVL Bottom : 3.88379
    Left VDC -DISC LVL Voltage1 : 4.97168
    Left VDC -DISC LVL Voltage2 : -5.05811
    -----
    Wien angle : 29.9923
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 604.61
    Wien field : 16.812
    Laser attenuation Hall A : 80
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : -2.33096
    Target OTR y-position : -1.08775
    Target OTR x-width : 2.5698
    Target OTR y-width : 2.36816
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.827329
    SLI vert. size mm : 0
    SLI y position : 1.57746
    -----
    Polarized 3He Target
    RTD1 (upstream) : 41.084
    RTD2 : 69.8145
    RTD3 : 121.201
    RTD4 : 63.457
    RTD5 (downstream) : 45.166
    RTD6 (pump cell up) : 279.668
    RTD7 (pump cell down) : 247.793
    HacAi_hpchan7: Temp at Ref. Cell : 39.5996
    HacAi_hpchan8: Temp at Ref. Cell : 41.7773
    HacAi_hpchan9: Temp at Ref. Cell : 40
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -9.37
    Oven Air Flow : 240.1
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 252
    HacOMEGA_READ : 240.2
    HacOMEGA_SP1 : 240
    HacOMEGA_PROP1 : 500
    HacOMEGA_RST1 : 180
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 34
    CLASER_TEMP : 14
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 0
    CLASER3_TEMP : 0
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP : 0
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 31
    CLASER5_TEMP : 19.2
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 0
    CLASER6_TEMP : 0
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 34.9991
    ntc1_temp : 26.0367
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.001
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9961
    ntc3_temp : 24.9791
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : 3.897
    DDM45_2disp1_read : 0.712066
    DDM45_3disp1_read : -5.522
    ----
    haPolHe3_Spin_State : -1
    haPolHe3_Flip_Sequence_ID : 36
    haPolHe3_Flip_Count : 0
    haPolHe3_EPR_ID : 0
    haPolHe3_EPR_POL : 0
    haPolHe3_Last_Flip_Start : 16:08:11 10/16/2008
    haPolHe3_Last_Flip_End : 19:00:00 12/31/1903
    haPolHe3_FLIP_NMR_PHASE : 0
    haPolHe3_FLIP_NMR_Mag : 0
    haPolHe3_FLIP_NMR_Pol : 62.5681
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : disabled
    HaGenTargPos : -9.37
    ----