     Run Number: 2176
     End of Run Comment:
    Run_type=Test,target_type=Polarized 3He,targetpol_poldir=Transverse-in-plane,targetpol_pol=57.95,beam_e0=4.734,beam_raster=on,beam_halfwaveplate=in,leftarm_p=1.34,leftarm_theta=45,leftarm_sieve=out,bbarm_i=710,bbarm_theta=45,bbarm_sieve=out,bbarm_zoff=0,comment_text=test run to check negative dead time
     
    
    PRESCALE FACTORS:ps1=1500   ps2=1   ps3=16777215   ps4=16777215   ps5=65535   ps6=130   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 1623764      [++]: 799603       [--]: 800123       [+-]: 800123       [-+]: 799603       
    TIME     : [ 0]: 8.965 mins  [++]: 4.345 mins  [--]: 4.346 mins  [+-]: 4.346 mins  [-+]: 4.345 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =         8.05373 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]: -16.82%      [++]: -18.42%      [--]: -18.56%      [+-]: -18.56%      [-+]: -18.42%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] :15.8/23641.8 Hz   T2[ 0] :2522.7/2522.7 Hz   T3[ 0] : 0.0/38.4 Hz   T4[ 0] : 0.0/23.4 Hz   T5[ 0] : 0.0/9.2  Hz   T6[ 0] :72.6/9441.4 Hz   T7[ 0] : 0.0/0.0  Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] :15.8/23671.8 Hz   T2[++] :2528.4/2528.4 Hz   T3[++] : 0.0/38.8 Hz   T4[++] : 0.0/23.6 Hz   T5[++] : 0.0/9.4  Hz   T6[++] :72.8/9458.9 Hz   T7[++] : 0.0/0.0  Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] :15.8/23654.7 Hz   T2[--] :2526.5/2526.5 Hz   T3[--] : 0.0/38.1 Hz   T4[--] : 0.0/23.4 Hz   T5[--] : 0.0/8.9  Hz   T6[--] :72.7/9449.8 Hz   T7[--] : 0.0/0.0  Hz   T8[--] :10.2/1024.0 Hz   
    T1[+-] :15.8/23655.3 Hz   T2[+-] :2526.5/2526.5 Hz   T3[+-] : 0.0/38.1 Hz   T4[+-] : 0.0/23.4 Hz   T5[+-] : 0.0/8.9  Hz   T6[+-] :72.7/9449.8 Hz   T7[+-] : 0.0/0.0  Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] :15.8/23670.7 Hz   T2[-+] :2528.4/2528.4 Hz   T3[-+] : 0.0/38.8 Hz   T4[-+] : 0.0/23.6 Hz   T5[-+] : 0.0/9.4  Hz   T6[-+] :72.8/9458.9 Hz   T7[-+] : 0.0/0.0  Hz   T8[-+] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] :   8477/12716451  T2[ 0] :1356936/1356936  T3[ 0] :      0/20643    T4[ 0] :      0/12600    T5[ 0] :      0/4926     T6[ 0] :  39064/5078356  T7[ 0] :      0/0        T8[ 0] :   5507/550790   
    T1[++] :   4114/6171670  T2[++] : 659197/659197   T3[++] :      0/10120    T4[++] :      0/6164     T5[++] :      0/2460     T6[++] :  18970/2466103  T7[++] :      0/0        T8[++] :   2669/266976   
    T1[--] :   4112/6168311  T2[--] : 658814/658814   T3[--] :      0/9923     T4[--] :      0/6099     T5[--] :      0/2314     T6[--] :  18955/2464177  T7[--] :      0/0        T8[--] :   2670/267023   
    T1[+-] :   4112/6168460  T2[+-] : 658814/658814   T3[+-] :      0/9923     T4[+-] :      0/6099     T5[+-] :      0/2314     T6[+-] :  18955/2464177  T7[+-] :      0/0        T8[+-] :   2670/267023   
    T1[-+] :   4114/6171383  T2[-+] : 659197/659197   T3[-+] :      0/10120    T4[-+] :      0/6164     T5[-+] :      0/2460     T6[-+] :  18970/2466103  T7[-+] :      0/0        T8[-+] :   2669/266976   
    
    AVERAGE CURRENT
    BCM x1 : 15.1067uA  BCM x3 : 15.1059uA  BCM x10: 14.2251uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :    14.42 ppm     BCM u3 :    2.416 ppm     BCM u10:   -1.656 ppm     
    BCM d1 :    15.76 ppm     BCM d3 :   -0.591 ppm     BCM d10:    -3.89 ppm     
    
    Target -
    BCM u1 :    14.35 ppm     BCM u3 :    2.416 ppm     BCM u10:   -1.614 ppm     
    BCM d1 :    15.69 ppm     BCM d3 :  -0.5653 ppm     BCM d10:   -3.929 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:0.008232       BCM u3 [ 0]:0.008231       BCM u10[ 0]:0.007278       
    BCM u1 [++]:0.003995       BCM u3 [++]:0.003995       BCM u10[++]:0.003532       
    BCM u1 [--]:0.003995       BCM u3 [--]:0.003995       BCM u10[--]:0.003532       
    BCM u1 [+-]:0.003995       BCM u3 [+-]:0.003995       BCM u10[+-]:0.003532       
    BCM u1 [-+]:0.003995       BCM u3 [-+]:0.003995       BCM u10[-+]:0.003532       
    
    BCM d1 [ 0]:0.008019       BCM d3 [ 0]:0.008019       BCM d10[ 0]:0.008024       
    BCM d1 [++]:0.003892       BCM d3 [++]:0.003892       BCM d10[++]:0.003894       
    BCM d1 [--]:0.003892       BCM d3 [--]:0.003892       BCM d10[--]:0.003895       
    BCM d1 [+-]:0.003892       BCM d3 [+-]:0.003892       BCM d10[+-]:0.003895       
    BCM d1 [-+]:0.003892       BCM d3 [-+]:0.003892       BCM d10[-+]:0.003894       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2176 at Sun Mar 15 04:06:17 EDT 2009
    
    Wien angle : 21.1919
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 1.34002
    Left Arm arm angle : 44.9985
    HALLA:p : 4734.42
    HALLA:dpp : -1.19582e-05
    Tiefenbach Hall A energy : 4734.42
    Left Arm Top VDC Current : 4.3457
    Left Arm Bottom VDC Current : 3.95508
    -----
    Left Arm Q1 momentum : 1.34018
    Left Arm Q1 power supply : 1008.26
    Left Arm Q1 gauss meter : -0.08546
    Left Arm Q2 gauss meter : 0.304
    Left Arm Q2 power supply current : 576.982
    Left Arm Q2 momentum : 1.33995
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 445.506
    Left Arm D1 momentum : 1.34002
    Left Arm D1 NMR : 0.496002
    Left Arm Q3 gauss meter : -0.26914
    Left Arm Q3 power supply current : 533.433
    Left Arm Q3 momentum : 1.33989
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 710
    BigBite magnet current readback : 706.553
    BigBite Gaussmeter readback : 1.2137
    -----
    Average current of the two cavities : 15.1183
    Current on Unser monitor : 8.40206
    Current on Upstream bcm : 15.1189
    Current on Downstream bcm : 15.1176
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 15.2658
    Hall C Current : 104.244
    MBSY1c magnet current (amp) : 197.946
    MBSY1c Bdl : 1.18393e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 4734.44
    Hall A momentum orbit correction (dpp) : -8.81713e-06
    Hall A setup momentum (MMSHLAE) : 4733.66
    Hall A energy (halla_MeV) : 4734.44
    Hall C energy (hallc_MeV) : 4736.81
    Delta(E)/E width (MV_AI_DXWID) : 2.70367
    IPM1C12.XPOS : -0.00514182
    IPM1H04A.XPOS : -1.34827
    IPM1H04A.YPOS : 2.49515
    IPM1H04B.XPOS : -0.802504
    IPM1H04B.YPOS : 2.50248
    -----
    HacL_HPE1313A:0_Ch58 : -0.254883
    HacL_HPE1313A:0_Ch55 : 22.8027
    HacL_HPE1313A:0_Ch54 : -0.321289
    Left Arm Angle Vernier : 30.8
    Left Arm Scattering Angle : 44.9985
    Left VDC -DISC LVL Top : 3.89453
    Left VDC -DISC LVL Bottom : 3.96094
    Left VDC -DISC LVL Voltage1 : 4.97559
    Left VDC -DISC LVL Voltage2 : -5.05762
    -----
    Wien angle : 21.1919
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 428.58
    Wien field : 11.879
    Laser attenuation Hall A : 318
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : -2.23698
    Target OTR y-position : -1.23254
    Target OTR x-width : 2.50769
    Target OTR y-width : 2.39074
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.827329
    SLI vert. size mm : 0
    SLI y position : 1.15681
    -----
    Polarized 3He Target
    RTD1 (upstream) : 43.6914
    RTD2 : 74.834
    RTD3 : 119.121
    RTD4 : 63.1152
    RTD5 (downstream) : 46.5137
    RTD6 (pump cell up) : 272.051
    RTD7 (pump cell down) : 242.168
    HacAi_hpchan7: Temp at Ref. Cell : 39.668
    HacAi_hpchan8: Temp at Ref. Cell : 41.8359
    HacAi_hpchan9: Temp at Ref. Cell : 39.668
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -9.38
    Oven Air Flow : 240.3
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 252
    HacOMEGA_READ : 240.3
    HacOMEGA_SP1 : 240
    HacOMEGA_PROP1 : 1000
    HacOMEGA_RST1 : 120
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 34
    CLASER_TEMP : 14
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 0
    CLASER3_TEMP : 0
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP : 0
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 31
    CLASER5_TEMP : 19.2
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 0
    CLASER6_TEMP : 0
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0041
    ntc1_temp : 26.0385
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.002
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9971
    ntc3_temp : 25.0365
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : 3.902
    DDM45_2disp1_read : 0.712066
    DDM45_3disp1_read : -5.532
    ----
    haPolHe3_Spin_State : 0
    haPolHe3_Flip_Sequence_ID : 36
    haPolHe3_Flip_Count : 0
    haPolHe3_EPR_ID : 0
    haPolHe3_EPR_POL : 0
    haPolHe3_Last_Flip_Start : 16:08:11 10/16/2008
    haPolHe3_Last_Flip_End : 19:00:00 12/31/1903
    haPolHe3_FLIP_NMR_PHASE : 0
    haPolHe3_FLIP_NMR_Mag : 0
    haPolHe3_FLIP_NMR_Pol : 57.9533
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : disabled
    HaGenTargPos : -9.38
    ----