Start_Run_20700,Run_type=Production,target_type=Polarized 3He,targetpol_poldir=Transverse-in-plane,targetpol_pol=60.24,beam_e0=4.734,beam_raster=on,beam_halfwaveplate=in,leftarm_p=1.34,leftarm_theta=45,leftarm_sieve=out,bbarm_i=710,bbarm_theta=45,bbarm_sieve=out,bbarm_zoff=,comment_text=production @ 15 uA
Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name adev
Log entry time 09:36:14 on March 15, 2009
Entry number 266263
keyword=Start_Run_20700,Run_type=Production,target_type=Polarized 3He,targetpol_poldir=Transverse-in-plane,targetpol_pol=60.24,beam_e0=4.734,beam_raster=on,beam_halfwaveplate=in,leftarm_p=1.34,leftarm_theta=45,leftarm_sieve=out,bbarm_i=710,bbarm_theta=45,bbarm_sieve=out,bbarm_zoff=,comment_text=production @ 15 uA
Run Timestamp: Sun Mar 15 09:35:57 EDT 2009
Beginning-of-run EPICS data for Run Number 20700 at Sun Mar 15 09:36:03 EDT 2009
Run_type=Production
target_type=Polarized 3He
targetpol_poldir=Transverse-in-plane
targetpol_pol=60.24
beam_e0=4.734
beam_raster=on
beam_halfwaveplate=in
leftarm_p=1.34
leftarm_theta=45
leftarm_sieve=out
bbarm_i=710
bbarm_theta=45
bbarm_sieve=out
bbarm_zoff=
comment_text=production @ 15 uA
; LEFT SPECTROMETER on adaql1/adev account.
; Do not use this for R-HRS
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string.
; Default factor is (2^24)-1 = 16.7M for ps1-4 and (2^16)-1 = 65K for ps5-8.
; T3 = main trigger S1.and.S2
; T4 = efficiency trigger (recommend to keep ~5 Hz)
; T8 = Scint. trigger for PVDIS.
; All other prescales should be maxed out.
ps1=16777215,ps2=16777215,ps3=1,ps4=1,ps5=65535,ps6=65535,ps7=65535,ps8=100
Left Arm Q1 momentum : 1.34026
Left Arm Q1 power supply : 1008.26
Left Arm Q1 gauss meter : -0.08548
Left Arm Q2 power supply current : 576.98
Left Arm Q2 momentum : 1.33994
Left Arm Q2 gauss meter : 0.3041
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 447.134
Left Arm D1 momentum : 1.34002
Left Arm D1 NMR : 0.496001
Left Arm Q3 power supply current : 533.43
Left Arm Q3 momentum : 1.33988
Left Arm Q3 gauss meter : -0.26915
Left Arm Q3 power supply polarity : disabled
Left Arm B Field Hall Probe (D-G) : -0.4787
-----
BigBite magnet current setpoint : 710
BigBite magnet current readback : 706.553
BigBite Gaussmeter readback : 1.2136
-----
Left Arm Top VDC Current : 4.6875
Left Arm Bottom VDC Current : 4.29688
Left Arm Top VDC voltage : 4.00342
Left Arm Bottom VDC voltage : 3.99902
-----
Average current of the two cavities : 9.38446
Current on Unser monitor : 2.07998
Current on Upstream bcm : 9.62535
Current on Downstream bcm : 9.14357
Upstream Cavity Coefficient : 48.345
Downstream Cavity Coefficient : 47.773
Current on IBC0L02 (source) : 9.74037
Hall C Current : 87.4761
Hall A momentum (Tiefenbach) (HALLA:p) : 4734.42
Hall A momentum orbit correction (dpp) : -1.21795e-05
Hall A setup momentum (MMSHLAE) : 4733.66
Hall A energy (halla_MeV) : 4734.42
Hall C energy (hallc_MeV) : 4736.47
Delta(E)/E width (MV_AI_DXWID) : 3.13939
MBSY1c magnet current (amp) : 197.946
MBSY1c Bdl : 1.18393e+06
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 5.2
-----
HacL_HPE1313A:0_Ch58 : -0.255371
HacL_HPE1313A:0_Ch55 : 22.8516
HacL_HPE1313A:0_Ch54 : -0.321289
Left Arm Angle Floor Angle : 45
Left Arm Angle Vernier : 30.8
Left Arm Scattering Angle : 44.9985
Left VDC -DISC LVL Top : 3.89551
Left VDC -DISC LVL Bottom : 3.96338
Left VDC -DISC LVL Voltage1 : 4.97412
Left VDC -DISC LVL Voltage2 : -5.05957
-----
IPM1C12.XPOS : 0.0167454
IPM1C12.YPOS : 0.0182661
IPM1H04A.XPOS : -1.32611
IPM1H04A.YPOS : 2.50354
IPM1H04B.XPOS : -0.781922
IPM1H04B.YPOS : 2.4995
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
-----
Wien angle : 21.1919
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 11.879
Laser attenuation Hall A : 211
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
target OTR x-position : -2.24196
target OTR y-position : -1.14465
target OTR x-width : 2.51886
target OTR y-width : 2.39159
target OTR data valid flag : No
target OTR In/Out : OTR is Out
-----
RTD1 (upstream) : 42.3828
RTD2 : 76.8359
RTD3 : 117.656
RTD4 : 61.8945
RTD5 (downstream) : 44.7656
RTD6 (pump cell up) : 272.051
RTD7 (pump cell down) : 242.168
HacAi_hpchan7: Temp at Ref. Cell : 39.6777
HacAi_hpchan8: Temp at Ref. Cell : 41.9336
HacAi_hpchan9: Temp at Ref. Cell : 39.8047
Reference Cell Gas Pressure (psi) : -277.5
Reference Cell System Vacuum (Torr) : -282
Cooling Jets Flow Rate : 0
Target position : -9.38
Oven Air Flow : 240.1
-----
HaGenTargBrake : enabled
HaGenTargBrake : enabled
HacOMEGA_AL1 : 252
HacOMEGA_READ : 239.8
HacOMEGA_SP1 : 240
HacOMEGA_PROP1 : 1000
HacOMEGA_RST1 : 120
HacOMEGA_RATE : 0
-----
CLASER_STATE_MB : Disabled
CLASER_RDCUR : 34
CLASER_TEMP : 14
-----
CLASER2_STATE_MB : Disabled
CLASER2_RDCUR : 0
CLASER2_TEMP : 0
-----
CLASERAB_STATE_MB : Disabled
CLASERAB_GETCUR0 : 0
CLASERAB_GETCUR1 : 0
CLASERAB_GETTEMP0 : 0
CLASERAB_GETTEMP1 : 0
-----
CLASER3_STATE_MB : Disabled
CLASER3_RDCUR : 0
CLASER3_TEMP : 0
-----
CLASER4_STATE_MB : Disabled
CLASER4_RDCUR : 0
CLASER4_TEMP : 0
-----
CLASER5_STATE_MB : Disabled
CLASER5_RDCUR : 31
CLASER5_TEMP : 19.2
-----
CLASER6_STATE_MB : Disabled
CLASER6_RDCUR : 0
CLASER6_TEMP : 0
-----
CLASERAB2_STATE_M : Disabled
CLASERAB2_GETCUR0 : 0
CLASERAB2_GETCUR1 : 0
CLASERAB2_GETTEMP0 : 0
CLASERAB2_GETTEMP1 : 0
----
CLASERAB3_STATE_M : Disabled
CLASERAB3_GETCUR0 : 0
CLASERAB3_GETCUR1 : 0
CLASERAB3_GETTEMP0 : 0
CLASERAB3_GETTEMP1 : 0
----
nld1_lasmdp : 35.0031
ntc1_temp : 26.0348
nld1_lasouti : Enable
ntc1_tecouti : Enable
nld1_lascond : 1024
----
nld2_lasmdp : 34.002
ntc2_temp : 20
nld2_lasouti : Enable
ntc2_tecouti : Enable
nld2_lascond : 1024
----
nld3_lasmdp : 35.9981
ntc3_temp : 25
nld3_lasouti : Enable
ntc3_tecouti : Enable
nld3_lascond : 1024
----
DDM45_1disp1_read : 3.902
DDM45_2disp1_read : 0.712066
DDM45_3disp1_read : -5.532
----
haPolHe3_Spin_State : 0
haPolHe3_Flip_Sequence_ID : 36
haPolHe3_Flip_Count : 0
haPolHe3_EPR_ID : 0
haPolHe3_EPR_POL : 0
haPolHe3_Last_Flip_Start : 16:08:11 10/16/2008
haPolHe3_Last_Flip_End : 19:00:00 12/31/1903
haPolHe3_FLIP_NMR_PHASE : 0
haPolHe3_FLIP_NMR_Mag : 0
haPolHe3_FLIP_NMR_Pol : 60.2434
HaGenTargSpin1 : disabled
HaGenTargSpin2 : disabled
HaGenTargPos : -9.38
----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 0.827329
SLI vert. size mm : 0
SLI y position : 1.15681
-----
Left S2 HV Left PMTs
S2 Slot0 ch0 Left : -1890.6
S2 Slot0 ch1 Left : -1872.7
S2 Slot0 ch2 Left : -2239.4
S2 Slot0 ch3 Left : -2045.7
S2 Slot0 ch4 Left : -2125.1
S2 Slot0 ch5 Left : -1828.9
S2 Slot0 ch6 Left : -2017.9
S2 Slot0 ch7 Left : -1932.1
S2 Slot0 ch8 Left : -1871.2
S2 Slot0 ch9 Left : -2056.4
S2 Slot0 ch10 Left : -2190.7
S2 Slot0 ch11 Left : -2009.8
S2 Slot13 ch0 Left : -2190.9
S2 Slot13 ch1 Left : -2166.3
S2 Slot13 ch2 Left : -1897.3
S2 Slot13 ch3 Left : -1743.2
-----
Left S2 HV Right PMTs
S2 Slot12 ch0 Right : -1767.2
S2 Slot12 ch1 Right : -1781.5
S2 Slot12 ch2 Right : -1968.6
S2 Slot12 ch3 Right : -1847.5
S2 Slot12 ch4 Right : -1984.6
S2 Slot12 ch5 Right : -1903.7
S2 Slot12 ch6 Right : -1959.1
S2 Slot12 ch7 Right : -1898.8
S2 Slot12 ch8 Right : -2014.9
S2 Slot12 ch9 Right : -1988.7
S2 Slot12 ch10 Right : -2040.6
S2 Slot12 ch11 Right : -1709.4
S2 Slot13 ch4 Right : -1756.1
S2 Slot13 ch5 Right : -1879.1
S2 Slot13 ch6 Right : -1858.7
S2 Slot13 ch7 Right : -1833.5
-----
Left S1 HV
S1 Slot1 ch0 : -1801.2
S1 Slot1 ch1 : -1796.8
S1 Slot1 ch2 : -1807.8
S1 Slot1 ch3 : -1840.8
S1 Slot1 ch4 : -1719
S1 Slot1 ch5 : -1890.6
S1 Slot1 ch6 : -1946.8
S1 Slot1 ch7 : -1720.7
S1 Slot1 ch8 : -1954.9
S1 Slot1 ch9 : -1772.3
S1 Slot1 ch10 : -1824.4
S1 Slot1 ch11 : -1743.7
-----
Left Cerenkov HV
GCER Slot2 ch0 : -1521.5
GCER Slot2 ch1 : -1452.3
GCER Slot2 ch2 : -1515.8
GCER Slot2 ch3 : -1431.8
GCER Slot2 ch4 : -1781.1
GCER Slot2 ch5 : -1985.2
GCER Slot2 ch6 : -29.4
GCER Slot2 ch7 : -1724.8
GCER Slot2 ch8 : -1993.8
GCER Slot2 ch9 : -1538.1
GCER Slot2 ch10 : -1663.9
GCER Slot2 ch11 : -15.3
-----
Left Pion Rejector Layer 1 HV
PRL1 Slot3 ch0 : -900.3
PRL1 Slot3 ch1 : -815.1
PRL1 Slot3 ch2 : -931.9
PRL1 Slot3 ch3 : -985.8
PRL1 Slot3 ch4 : -787.1
PRL1 Slot3 ch5 : -886.9
PRL1 Slot3 ch6 : -1095
PRL1 Slot3 ch7 : -1012.6
PRL1 Slot3 ch8 : -834.9
PRL1 Slot3 ch9 : -816.1
PRL1 Slot3 ch10 : -886.6
PRL1 Slot3 ch11 : -809.5
PRL1 Slot4 ch0 : -901.1
PRL1 Slot4 ch1 : -931.4
PRL1 Slot4 ch2 : -768.2
PRL1 Slot4 ch3 : -941.2
PRL1 Slot4 ch4 : -921.7
PRL1 Slot4 ch5 : -825.1
PRL1 Slot4 ch6 : -837.5
PRL1 Slot4 ch7 : -829.5
PRL1 Slot4 ch8 : -1190.3
PRL1 Slot4 ch9 : -1039.2
PRL1 Slot4 ch10 : -1079.5
PRL1 Slot4 ch11 : -877.4
PRL1 Slot5 ch0 : -1075.5
PRL1 Slot5 ch1 : -902.4
PRL1 Slot5 ch2 : -945.2
PRL1 Slot5 ch3 : -764.9
PRL1 Slot5 ch4 : -918.3
PRL1 Slot5 ch5 : -823.3
PRL1 Slot5 ch6 : -838.7
PRL1 Slot5 ch7 : -891.8
PRL1 Slot5 ch8 : -786.7
PRL1 Slot5 ch9 : -841.4
PRL1 Slot5 ch10 : -16.5
PRL1 Slot5 ch11 : -25.6
-----
Left Pion Rejector Layer 2 HV
PRL2 Slot9 ch0 : -900.6
PRL2 Slot9 ch1 : -918.8
PRL2 Slot9 ch2 : -794.8
PRL2 Slot9 ch3 : -883.7
PRL2 Slot9 ch4 : -811.6
PRL2 Slot9 ch5 : -930.8
PRL2 Slot9 ch6 : -852.2
PRL2 Slot9 ch7 : -886.7
PRL2 Slot9 ch8 : -827.5
PRL2 Slot9 ch9 : -777.6
PRL2 Slot9 ch10 : -834
PRL2 Slot9 ch11 : -842.2
PRL2 Slot10 ch0 : -754.2
PRL2 Slot10 ch1 : -799.6
PRL2 Slot10 ch2 : -861.1
PRL2 Slot10 ch3 : -881.2
PRL2 Slot10 ch4 : -969.2
PRL2 Slot10 ch5 : -805.9
PRL2 Slot10 ch6 : -796.1
PRL2 Slot10 ch7 : -821.8
PRL2 Slot10 ch8 : -773.8
PRL2 Slot10 ch9 : -721.8
PRL2 Slot10 ch10 : -901.8
PRL2 Slot10 ch11 : -795.7
PRL2 Slot11 ch0 : -989.2
PRL2 Slot11 ch1 : -922.7
PRL2 Slot11 ch2 : -863.6
PRL2 Slot11 ch3 : -1079.1
PRL2 Slot11 ch4 : -1053.3
PRL2 Slot11 ch5 : -805.4
PRL2 Slot11 ch6 : -858.9
PRL2 Slot11 ch7 : -1007.6
PRL2 Slot11 ch8 : -903.7
PRL2 Slot11 ch9 : -863.5
PRL2 Slot11 ch10 : -3.7
PRL2 Slot11 ch11 : -11.7
-----
# Map BB_DE Measured Voltage
1 : -1284 -1477
2 : -1240 -1400
3 : -1208 -1485
4 : -1517 -1531
5 : -1303 -1342
6 : -1463 -1436
7 : -1194 -1182
8 : -1280 -1358
9 : -1098 -1787
10 : -1576 -1158
11 : -1424 -1452
12 : -1230 -1633
13 : -1581 -1557
14 : -1196 -1520
15 : -1412 -1578
16 : -1347 -1280
17 : -1022 -1554
18 : -1324 -1259
19 : -1385 -1391
20 : -1293 -1460
21 : -1447 -1458
22 : -1532 -1618
23 : -1574 -1414
24 : -1504 -1254
# Map BB_DE Measured Current
1 : -129 -167
2 : -131 -157
3 : -130 -165
4 : -161 -173
5 : -139 -144
6 : -160 -158
7 : -131 -128
8 : -137 -146
9 : -121 -196
10 : -166 -124
11 : -152 -156
12 : -135 -182
13 : -173 -165
14 : -129 -168
15 : -153 -175
16 : -147 -135
17 : -109 -164
18 : -148 -135
19 : -155 -149
20 : -146 -160
21 : -157 -155
22 : -173 -152
23 : -175 -152
24 : -163 -135
# Map BB_E Measured Voltage
1 : -1482 -1498
2 : -1534 -1227
3 : -1268 -1316
4 : -1177 -1236
5 : -1280 -1576
6 : -1408 -1490
7 : -1508 -1209
8 : -1306 -1472
9 : -1210 -1527
10 : -1150 -1242
11 : -1678 -1550
12 : -1239 -1569
13 : -1549 -1379
14 : -1223 -1515
15 : -1614 -1283
16 : -1229 -1612
17 : -1531 -1387
18 : -1027 -1302
19 : -1367 -1712
20 : -1519 -1579
21 : -1341 -1599
22 : -1569 -1147
23 : -1358 -1286
24 : -1140 -4
# Map BB_E Measured Current
1 : -157 -160
2 : -168 -130
3 : -135 -144
4 : -129 -135
5 : -140 -170
6 : -152 -164
7 : -161 -131
8 : -140 -162
9 : -129 -162
10 : -121 -132
11 : -178 -164
12 : -133 -168
13 : -169 -143
14 : -127 -155
15 : -178 -131
16 : -134 -154
17 : -167 -153
18 : -113 -132
19 : -144 -165
20 : -162 -174
21 : -142 -166
22 : -170 -120
23 : -144 -126
24 : -120 -2
# Map BB_SC_R Measured Voltage
1 : -1292
2 : -1230
3 : -1276
4 : -1239
5 : -1291
6 : -1295
7 : -1362
8 : -1192
9 : -1271
10 : -1318
11 : -1404
12 : -1254
13 : -1390
# Map BB_SC_R Measured Current
1 : -489
2 : -465
3 : -483
4 : -470
5 : -487
6 : -492
7 : -516
8 : -451
9 : -492
10 : -498
11 : -532
12 : -474
13 : -526
# Map BB_DC Measured Voltage
1 : -1625 -1628 -1665 -1663
2 : -1664 -1661 -1713 -1706
3 : -1658 -1654 -1696 -1695
# Map BB_DC Measured Current
1 : -7 -7 -79 -76
2 : -12 -11 -115 -109
3 : -9 -9 -89 -89
# Map BB_PS_R Measured Voltage
1 : -870
2 : -828
3 : -832
4 : -828
5 : -913
6 : -890
7 : -881
8 : -878
9 : -935
10 : -907
11 : -912
12 : -891
13 : -889
14 : -856
15 : -900
16 : -976
17 : -893
18 : -909
19 : -888
20 : -922
21 : -925
22 : -884
23 : -882
24 : -892
25 : -849
26 : -908
27 : -898
# Map BB_PS_R Measured Current
1 : -223
2 : -211
3 : -213
4 : -213
5 : -234
6 : -227
7 : -225
8 : -223
9 : -240
10 : -232
11 : -232
12 : -229
13 : -228
14 : -219
15 : -230
16 : -251
17 : -229
18 : -232
19 : -227
20 : -236
21 : -236
22 : -226
23 : -226
24 : -228
25 : -218
26 : -233
27 : -230
# Map BB_SC_L Measured Voltage
1 : -1421
2 : -1551
3 : -1310
4 : -1401
5 : -1417
6 : -1460
7 : -1500
8 : -1307
9 : -1433
10 : -1425
11 : -1486
12 : -1314
13 : -1358
# Map BB_SC_L Measured Current
1 : -512
2 : -521
3 : -489
4 : -487
5 : -478
6 : -527
7 : -531
8 : -472
9 : -498
10 : -513
11 : -549
12 : -496
13 : -513
# Map BB_CER Measured Voltage
1 : 1950 1522
2 : 1972 1750
3 : 981 1469
4 : 1251 1555
5 : 1151 1371
6 : 1165 2070
7 : 1391 1820
8 : 1151 1451
9 : 851 1403
10 : 1290 1657
# Map BB_CER Measured Current
1 : 703 533
2 : 709 614
3 : 352 516
4 : 447 545
5 : 412 478
6 : 417 728
7 : 498 636
8 : 412 508
9 : 306 494
10 : 460 581
# Map BB_PS_L Measured Voltage
1 : -877
2 : -866
3 : -816
4 : -875
5 : -897
6 : -879
7 : -875
8 : -862
9 : -878
10 : -896
11 : -870
12 : -885
13 : -878
14 : -972
15 : -914
16 : -888
17 : -888
18 : -916
19 : -878
20 : -876
21 : -864
22 : -858
23 : -858
24 : -855
25 : -861
26 : -835
27 : -856
# Map BB_PS_L Measured Current
1 : -225
2 : -222
3 : -209
4 : -224
5 : -230
6 : -225
7 : -223
8 : -220
9 : -225
10 : -230
11 : -223
12 : -227
13 : -226
14 : -248
15 : -233
16 : -230
17 : -228
18 : -235
19 : -225
20 : -224
21 : -220
22 : -220
23 : -220
24 : -219
25 : -219
26 : -213
27 : -220
# Map BB_SH Measured Voltage
1 : -1284 -1240 -1208 -1517 -1680 -1676 -1294
2 : -1303 -1463 -1194 -1424 -1346 -1319 -1567
3 : -1280 -1098 -1576 -1424 -1501 -1531 -1443
4 : -1230 -1581 -1196 -1614 -1362 -1735 -1604
5 : -1412 -1347 -1022 -1324 -1464 -1424 -1447
6 : -1385 -1293 -1447 -1644 -1684 -1347 -1295
7 : -1532 -1574 -1504 -1477 -1564 -1518 -1589
8 : -1400 -1485 -1531 -1045 -1565 -1551 -1273
9 : -1342 -1436 -1182 -1358 -1542 -1155 -1429
10 : -1787 -1158 -1452 -1175 -1257 -1257 -1520
11 : -1633 -1557 -1520 -1578 -1390 -1437 -1203
12 : -1280 -1554 -1259 -1492 -1444 -1486 -1540
13 : -1391 -1460 -1458 -1618 -1238 -1391 -1533
14 : -1414 -1254 -1482 -1304 -1503 -1579 -1561
15 : -1534 -1268 -1177 -1280 -1494 -1414 -1387
16 : -1408 -1508 -1306 -1506 -1415 -1590 -1183
17 : -1210 -1150 -1678 -1239 -1361 -1488 -1585
18 : -1549 -1223 -1614 -1127 -1683 -1511 -1421
19 : -1229 -1531 -1027 -1367 -1426 -1654 -1364
20 : -1519 -1341 -1569 -1277 -1536 -1269 -1508
21 : -1358 -1140 -1498 -1227 -1574 -1372 -1260
22 : -1316 -1236 -1576 -1375 -1492 -1553 -1459
23 : -1490 -1209 -1472 -1527 -1596 -1056 -1287
24 : -1242 -1550 -1569 -1515 -1362 -1505 -1511
25 : -1379 -1515 -1283 -1612 -1324 -1208 -1638
26 : -1387 -1302 -1712 -1236 -1186 -1635 -1634
27 : -1579 -1599 -1147 -1286 -1181 -1450 -1536
# Map BB_SH Measured Current
1 : -129 -131 -130 -161 -185 -181 -138
2 : -139 -160 -131 -151 -142 -140 -172
3 : -137 -121 -166 -152 -161 -164 -151
4 : -135 -173 -129 -170 -147 -176 -168
5 : -153 -147 -109 -148 -141 -151 -148
6 : -155 -146 -157 -176 -174 -139 -141
7 : -173 -175 -163 -167 -170 -156 -170
8 : -157 -165 -173 -114 -164 -172 -137
9 : -144 -158 -128 -146 -170 -126 -151
10 : -196 -124 -156 -130 -139 -131 -163
11 : -182 -165 -168 -175 -152 -153 -132
12 : -135 -164 -135 -157 -155 -157 -166
13 : -149 -160 -155 -152 -131 -150 -161
14 : -152 -135 -157 -140 -160 -174 -166
15 : -168 -135 -129 -140 -159 -156 -148
16 : -152 -161 -140 -160 -150 -170 -125
17 : -129 -121 -178 -133 -140 -160 -171
18 : -169 -127 -178 -120 -185 -165 -153
19 : -134 -167 -113 -144 -153 -177 -144
20 : -162 -142 -170 -141 -162 -135 -162
21 : -144 -120 -160 -130 -169 -146 -135
22 : -144 -135 -170 -148 -160 -166 -159
23 : -164 -131 -162 -162 -172 -117 -136
24 : -132 -164 -168 -169 -142 -161 -164
25 : -143 -155 -131 -154 -140 -129 -175
26 : -153 -132 -165 -134 -127 -179 -174
27 : -174 -166 -120 -126 -124 -155 -169
Threshold for 'mwdc_front' is +3.898 V (2580)
Threshold for 'mwdc_middle' is +4.800 V (2703)
Threshold for 'mwdc_back' is +4.800 V (2703)
Threshold for 'BB_Sh' is -0.110 V (1854)
Threshold for 'BB_PSh' is -0.015 V (2048)
Threshold for 'BB_Sh_2' is -0.110 V (1864)
Threshold for 'BB_Cer' is -0.070 V (1925)
CODA config : config LeftHrs RightHrs
HAPPEX run : 31035