     Run Number: 20701
     End of Run Comment:
    Run_type=Production,target_type=Polarized 3He,targetpol_poldir=Transverse-in-plane,targetpol_pol=60.65,beam_e0=4.734,beam_raster=on,beam_halfwaveplate=in,leftarm_p=1.34,leftarm_theta=45,leftarm_sieve=out,bbarm_i=710,bbarm_theta=45,bbarm_sieve=out,bbarm_zoff=,comment_text=production @ 15 uA Kinematic 4F
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=16777215   ps3=1   ps4=1   ps5=65535   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 278862       [++]: 137447       [--]: 137368       [+-]: 137421       [-+]: 137372       
    TIME     : [ 0]: 52.549 mins  [++]: 25.985 mins  [--]: 25.885 mins  [+-]: 25.901 mins  [-+]: 25.995 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -9.84606 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:   3.37%      [++]:   3.82%      [--]:   3.02%      [+-]:   3.76%      [-+]:   3.10%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] : 0.0/0.0  Hz   T2[ 0] : 0.0/0.0  Hz   T3[ 0] :57.9/57.9 Hz   T4[ 0] :23.4/23.4 Hz   T5[ 0] : 0.0/0.0  Hz   T6[ 0] : 0.0/0.0  Hz   T7[ 0] : 0.0/0.0  Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] : 0.0/0.0  Hz   T2[++] : 0.0/0.0  Hz   T3[++] :58.0/58.0 Hz   T4[++] :23.4/23.4 Hz   T5[++] : 0.0/0.0  Hz   T6[++] : 0.0/0.0  Hz   T7[++] : 0.0/0.0  Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] : 0.0/0.0  Hz   T2[--] : 0.0/0.0  Hz   T3[--] :57.7/57.7 Hz   T4[--] :23.3/23.3 Hz   T5[--] : 0.0/0.0  Hz   T6[--] : 0.0/0.0  Hz   T7[--] : 0.0/0.0  Hz   T8[--] :10.2/1024.0 Hz   
    T1[+-] : 0.0/0.0  Hz   T2[+-] : 0.0/0.0  Hz   T3[+-] :58.2/58.2 Hz   T4[+-] :23.5/23.5 Hz   T5[+-] : 0.0/0.0  Hz   T6[+-] : 0.0/0.0  Hz   T7[+-] : 0.0/0.0  Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] : 0.0/0.0  Hz   T2[-+] : 0.0/0.0  Hz   T3[-+] :57.5/57.5 Hz   T4[-+] :23.2/23.2 Hz   T5[-+] : 0.0/0.0  Hz   T6[-+] : 0.0/0.0  Hz   T7[-+] : 0.0/0.0  Hz   T8[-+] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] :      0/0        T2[ 0] :      0/0        T3[ 0] : 182670/182670   T4[ 0] :  73645/73645    T5[ 0] :      0/0        T6[ 0] :      0/0        T7[ 0] :      0/0        T8[ 0] :  32285/3228598  
    T1[++] :      0/0        T2[++] :      0/0        T3[++] :  90455/90455    T4[++] :  36492/36492    T5[++] :      0/0        T6[++] :      0/0        T7[++] :      0/0        T8[++] :  15965/1596507  
    T1[--] :      0/0        T2[--] :      0/0        T3[--] :  89627/89627    T4[--] :  36125/36125    T5[--] :      0/0        T6[--] :      0/0        T7[--] :      0/0        T8[--] :  15903/1590351  
    T1[+-] :      0/0        T2[+-] :      0/0        T3[+-] :  90444/90444    T4[+-] :  36447/36447    T5[+-] :      0/0        T6[+-] :      0/0        T7[+-] :      0/0        T8[+-] :  15913/1591370  
    T1[-+] :      0/0        T2[-+] :      0/0        T3[-+] :  89638/89638    T4[-+] :  36165/36165    T5[-+] :      0/0        T6[-+] :      0/0        T7[-+] :      0/0        T8[-+] :  15971/1597127  
    
    AVERAGE CURRENT
    BCM x1 : 14.4655uA  BCM x3 : 14.4730uA  BCM x10: 14.4818uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :    343.8 ppm     BCM u3 :   0.1773 ppm     BCM u10:   -0.133 ppm     
    BCM d1 :    103.2 ppm     BCM d3 :  -0.1786 ppm     BCM d10:    387.6 ppm     
    
    Target -
    BCM u1 :   -33.57 ppm     BCM u3 :    23.83 ppm     BCM u10:    24.14 ppm     
    BCM d1 :    55.03 ppm     BCM d3 :    24.06 ppm     BCM d10:    203.7 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:0.04578        BCM u3 [ 0]:0.04579        BCM u10[ 0]:0.04579        
    BCM u1 [++]:0.02257        BCM u3 [++]:0.02256        BCM u10[++]:0.02256        
    BCM u1 [--]:0.02255        BCM u3 [--]:0.02256        BCM u10[--]:0.02256        
    BCM u1 [+-]:0.02255        BCM u3 [+-]:0.02256        BCM u10[+-]:0.02256        
    BCM u1 [-+]:0.02255        BCM u3 [-+]:0.02256        BCM u10[-+]:0.02256        
    
    BCM d1 [ 0]:0.04543        BCM d3 [ 0]:0.04547        BCM d10[ 0]:0.04553        
    BCM d1 [++]:0.02238        BCM d3 [++]:0.0224         BCM d10[++]:0.02245        
    BCM d1 [--]:0.02238        BCM d3 [--]:0.0224         BCM d10[--]:0.02243        
    BCM d1 [+-]:0.02238        BCM d3 [+-]:0.0224         BCM d10[+-]:0.02243        
    BCM d1 [-+]:0.02238        BCM d3 [-+]:0.0224         BCM d10[-+]:0.02244        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 20701 at Sun Mar 15 11:00:16 EDT 2009
    
    Wien angle : 21.1919
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 1.19
    Left Arm arm angle : 44.9985
    HALLA:p : 4734.43
    HALLA:dpp : -1.14042e-05
    Tiefenbach Hall A energy : 4734.43
    Left Arm Top VDC Current : -1.5625
    Left Arm Bottom VDC Current : -1.07422
    -----
    Left Arm Q1 momentum : 1.19012
    Left Arm Q1 power supply : 895.361
    Left Arm Q1 gauss meter : -0.07596
    Left Arm Q2 gauss meter : 0.2701
    Left Arm Q2 power supply current : 512.451
    Left Arm Q2 momentum : 1.19009
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 395.991
    Left Arm D1 momentum : 1.19
    Left Arm D1 NMR : 0.440521
    Left Arm Q3 gauss meter : -0.23901
    Left Arm Q3 power supply current : 473.664
    Left Arm Q3 momentum : 1.18975
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 710
    BigBite magnet current readback : 706.537
    BigBite Gaussmeter readback : 1.2136
    -----
    Average current of the two cavities : 15.0767
    Current on Unser monitor : 7.91323
    Current on Upstream bcm : 15.0205
    Current on Downstream bcm : 15.1329
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 15.1328
    Hall C Current : 29.7256
    MBSY1c magnet current (amp) : 197.946
    MBSY1c Bdl : 1.18393e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 4734.42
    Hall A momentum orbit correction (dpp) : -1.21091e-05
    Hall A setup momentum (MMSHLAE) : 4733.66
    Hall A energy (halla_MeV) : 4734.42
    Hall C energy (hallc_MeV) : 4737.26
    Delta(E)/E width (MV_AI_DXWID) : 2.75685
    IPM1C12.XPOS : 0.00266865
    IPM1H04A.XPOS : -1.34706
    IPM1H04A.YPOS : 2.49202
    IPM1H04B.XPOS : -0.800617
    IPM1H04B.YPOS : 2.50566
    -----
    HacL_HPE1313A:0_Ch58 : -0.254883
    HacL_HPE1313A:0_Ch55 : 22.8516
    HacL_HPE1313A:0_Ch54 : -0.321289
    Left Arm Angle Vernier : 30.8
    Left Arm Scattering Angle : 44.9985
    Left VDC -DISC LVL Top : 3.896
    Left VDC -DISC LVL Bottom : 3.96387
    Left VDC -DISC LVL Voltage1 : 4.97412
    Left VDC -DISC LVL Voltage2 : -5.05957
    -----
    Wien angle : 21.1919
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 428.58
    Wien field : 11.879
    Laser attenuation Hall A : 326
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : -2.33564
    Target OTR y-position : -1.30681
    Target OTR x-width : 2.57567
    Target OTR y-width : 2.4221
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.827329
    SLI vert. size mm : 0
    SLI y position : 1.15681
    -----
    Polarized 3He Target
    RTD1 (upstream) : 43.0762
    RTD2 : 75.4883
    RTD3 : 117.285
    RTD4 : 62.0703
    RTD5 (downstream) : 46.0645
    RTD6 (pump cell up) : 271.758
    RTD7 (pump cell down) : 241.934
    HacAi_hpchan7: Temp at Ref. Cell : 39.668
    HacAi_hpchan8: Temp at Ref. Cell : 41.7969
    HacAi_hpchan9: Temp at Ref. Cell : 39.6387
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -9.38
    Oven Air Flow : 239.7
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 252
    HacOMEGA_READ : 239.8
    HacOMEGA_SP1 : 240
    HacOMEGA_PROP1 : 1000
    HacOMEGA_RST1 : 120
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 34
    CLASER_TEMP : 14
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 0
    CLASER3_TEMP : 0
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP : 0
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 31
    CLASER5_TEMP : 19.2
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 0
    CLASER6_TEMP : 0
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0031
    ntc1_temp : 26.0385
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.002
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9971
    ntc3_temp : 25
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : 3.902
    DDM45_2disp1_read : 0.712066
    DDM45_3disp1_read : -5.532
    ----
    haPolHe3_Spin_State : 0
    haPolHe3_Flip_Sequence_ID : 36
    haPolHe3_Flip_Count : 0
    haPolHe3_EPR_ID : 0
    haPolHe3_EPR_POL : 0
    haPolHe3_Last_Flip_Start : 16:08:11 10/16/2008
    haPolHe3_Last_Flip_End : 19:00:00 12/31/1903
    haPolHe3_FLIP_NMR_PHASE : 0
    haPolHe3_FLIP_NMR_Mag : 0
    haPolHe3_FLIP_NMR_Pol : 60.6453
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : disabled
    HaGenTargPos : -9.38
    ----