     Run Number: 20709
     End of Run Comment:
    Run_type=Production,target_type=Polarized 3He,targetpol_poldir=Transverse-in-plane,targetpol_pol=60.65,beam_e0=4.734,beam_raster=on,beam_halfwaveplate=in,leftarm_p=1.19,leftarm_theta=45,leftarm_sieve=out,bbarm_i=710,bbarm_theta=45,bbarm_sieve=out,bbarm_zoff=,comment_text=15 uA Kinematic 4F
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=16777215   ps3=1   ps4=1   ps5=65535   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 392843       [++]: 193589       [--]: 193480       [+-]: 193537       [-+]: 193487       
    TIME     : [ 0]: 91.838 mins  [++]: 45.404 mins  [--]: 45.238 mins  [+-]: 45.266 mins  [-+]: 45.425 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =       -16.71435 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:   2.61%      [++]:   2.86%      [--]:   2.43%      [+-]:   2.81%      [-+]:   2.52%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] : 0.0/0.0  Hz   T2[ 0] : 0.0/0.0  Hz   T3[ 0] :37.4/37.4 Hz   T4[ 0] :25.6/25.6 Hz   T5[ 0] : 0.0/0.0  Hz   T6[ 0] : 0.0/0.0  Hz   T7[ 0] : 0.0/0.0  Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] : 0.0/0.0  Hz   T2[++] : 0.0/0.0  Hz   T3[++] :37.4/37.4 Hz   T4[++] :25.5/25.5 Hz   T5[++] : 0.0/0.0  Hz   T6[++] : 0.0/0.0  Hz   T7[++] : 0.0/0.0  Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] : 0.0/0.0  Hz   T2[--] : 0.0/0.0  Hz   T3[--] :37.2/37.2 Hz   T4[--] :25.6/25.6 Hz   T5[--] : 0.0/0.0  Hz   T6[--] : 0.0/0.0  Hz   T7[--] : 0.0/0.0  Hz   T8[--] :10.2/1024.0 Hz   
    T1[+-] : 0.0/0.0  Hz   T2[+-] : 0.0/0.0  Hz   T3[+-] :37.5/37.5 Hz   T4[+-] :25.6/25.6 Hz   T5[+-] : 0.0/0.0  Hz   T6[+-] : 0.0/0.0  Hz   T7[+-] : 0.0/0.0  Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] : 0.0/0.0  Hz   T2[-+] : 0.0/0.0  Hz   T3[-+] :37.0/37.0 Hz   T4[-+] :25.6/25.6 Hz   T5[-+] : 0.0/0.0  Hz   T6[-+] : 0.0/0.0  Hz   T7[-+] : 0.0/0.0  Hz   T8[-+] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] :      0/0        T2[ 0] :      0/0        T3[ 0] : 205810/205810   T4[ 0] : 141152/141152   T5[ 0] :      0/0        T6[ 0] :      0/0        T7[ 0] :      0/0        T8[ 0] :  56425/5642544  
    T1[++] :      0/0        T2[++] :      0/0        T3[++] : 101847/101847   T4[++] :  69558/69558    T5[++] :      0/0        T6[++] :      0/0        T7[++] :      0/0        T8[++] :  27896/2789620  
    T1[--] :      0/0        T2[--] :      0/0        T3[--] : 100948/100948   T4[--] :  69583/69583    T5[--] :      0/0        T6[--] :      0/0        T7[--] :      0/0        T8[--] :  27794/2779414  
    T1[+-] :      0/0        T2[+-] :      0/0        T3[+-] : 101834/101834   T4[+-] :  69505/69505    T5[+-] :      0/0        T6[+-] :      0/0        T7[+-] :      0/0        T8[+-] :  27811/2781144  
    T1[-+] :      0/0        T2[-+] :      0/0        T3[-+] : 100955/100955   T4[-+] :  69644/69644    T5[-+] :      0/0        T6[-+] :      0/0        T7[-+] :      0/0        T8[-+] :  27908/2790884  
    
    AVERAGE CURRENT
    BCM x1 : 14.1411uA  BCM x3 : 14.1482uA  BCM x10: 14.1528uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :    345.4 ppm     BCM u3 :    0.235 ppm     BCM u10: -0.09139 ppm     
    BCM d1 :    113.8 ppm     BCM d3 :  -0.0779 ppm     BCM d10:    390.3 ppm     
    
    Target -
    BCM u1 :   -35.13 ppm     BCM u3 :       20 ppm     BCM u10:    20.24 ppm     
    BCM d1 :    52.66 ppm     BCM d3 :    20.49 ppm     BCM d10:    199.1 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:0.07772        BCM u3 [ 0]:0.07775        BCM u10[ 0]:0.07774        
    BCM u1 [++]:0.03831        BCM u3 [++]:0.0383         BCM u10[++]:0.0383         
    BCM u1 [--]:0.03829        BCM u3 [--]:0.0383         BCM u10[--]:0.03829        
    BCM u1 [+-]:0.03828        BCM u3 [+-]:0.0383         BCM u10[+-]:0.0383         
    BCM u1 [-+]:0.03828        BCM u3 [-+]:0.0383         BCM u10[-+]:0.0383         
    
    BCM d1 [ 0]:0.07812        BCM d3 [ 0]:0.07817        BCM d10[ 0]:0.07823        
    BCM d1 [++]:0.03848        BCM d3 [++]:0.03851        BCM d10[++]:0.03857        
    BCM d1 [--]:0.03847        BCM d3 [--]:0.03851        BCM d10[--]:0.03854        
    BCM d1 [+-]:0.03848        BCM d3 [+-]:0.03851        BCM d10[+-]:0.03854        
    BCM d1 [-+]:0.03848        BCM d3 [-+]:0.03851        BCM d10[-+]:0.03855        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 20709 at Sun Mar 15 22:33:45 EDT 2009
    
    Wien angle : 21.1919
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 1.34
    Left Arm arm angle : 44.9985
    HALLA:p : 4734.42
    HALLA:dpp : -1.28518e-05
    Tiefenbach Hall A energy : 4734.42
    Left Arm Top VDC Current : -2.00195
    Left Arm Bottom VDC Current : 0.292969
    -----
    Left Arm Q1 momentum : 1.34026
    Left Arm Q1 power supply : 1008.32
    Left Arm Q1 gauss meter : -0.08549
    Left Arm Q2 gauss meter : 0.304
    Left Arm Q2 power supply current : 576.842
    Left Arm Q2 momentum : 1.33962
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 446.087
    Left Arm D1 momentum : 1.34
    Left Arm D1 NMR : 0.495995
    Left Arm Q3 gauss meter : -0.2692
    Left Arm Q3 power supply current : 533.447
    Left Arm Q3 momentum : 1.33992
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 710
    BigBite magnet current readback : 706.553
    BigBite Gaussmeter readback : -1.2139
    -----
    Average current of the two cavities : 15.1374
    Current on Unser monitor : 7.17262
    Current on Upstream bcm : 15.0862
    Current on Downstream bcm : 15.1887
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 15.2482
    Hall C Current : 29.294
    MBSY1c magnet current (amp) : 197.946
    MBSY1c Bdl : 1.18393e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 4734.41
    Hall A momentum orbit correction (dpp) : -1.555e-05
    Hall A setup momentum (MMSHLAE) : 4733.66
    Hall A energy (halla_MeV) : 4734.41
    Hall C energy (hallc_MeV) : 4737.26
    Delta(E)/E width (MV_AI_DXWID) : 2.43502
    IPM1C12.XPOS : 0.00239834
    IPM1H04A.XPOS : -1.31749
    IPM1H04A.YPOS : 2.50296
    IPM1H04B.XPOS : -0.781155
    IPM1H04B.YPOS : 2.49295
    -----
    HacL_HPE1313A:0_Ch58 : -0.255859
    HacL_HPE1313A:0_Ch55 : 22.8027
    HacL_HPE1313A:0_Ch54 : -0.321289
    Left Arm Angle Vernier : 30.8
    Left Arm Scattering Angle : 44.9985
    Left VDC -DISC LVL Top : 3.89453
    Left VDC -DISC LVL Bottom : 3.96143
    Left VDC -DISC LVL Voltage1 : 4.97363
    Left VDC -DISC LVL Voltage2 : -5.06055
    -----
    Wien angle : 21.1919
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 428.58
    Wien field : 11.879
    Laser attenuation Hall A : 347
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : -2.30732
    Target OTR y-position : -1.13884
    Target OTR x-width : 2.58812
    Target OTR y-width : 2.39928
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 0.827329
    SLI vert. size mm : 0
    SLI y position : 1.15681
    -----
    Polarized 3He Target
    RTD1 (upstream) : 43.3008
    RTD2 : 76.5234
    RTD3 : 119.102
    RTD4 : 62.5098
    RTD5 (downstream) : 46.3379
    RTD6 (pump cell up) : 273.398
    RTD7 (pump cell down) : 242.402
    HacAi_hpchan7: Temp at Ref. Cell : 39.6973
    HacAi_hpchan8: Temp at Ref. Cell : 41.8652
    HacAi_hpchan9: Temp at Ref. Cell : 39.9121
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -9.38
    Oven Air Flow : 239.7
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 252
    HacOMEGA_READ : 239.6
    HacOMEGA_SP1 : 240
    HacOMEGA_PROP1 : 1000
    HacOMEGA_RST1 : 120
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 34
    CLASER_TEMP : 14
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 0
    CLASER3_TEMP : 0
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP : 0
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 31
    CLASER5_TEMP : 19.2
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 0
    CLASER6_TEMP : 0
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0031
    ntc1_temp : 26.0367
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.002
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9971
    ntc3_temp : 25.0261
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : 4.361
    DDM45_2disp1_read : 0
    DDM45_3disp1_read : -6.318
    ----
    haPolHe3_Spin_State : 0
    haPolHe3_Flip_Sequence_ID : 36
    haPolHe3_Flip_Count : 0
    haPolHe3_EPR_ID : 0
    haPolHe3_EPR_POL : 0
    haPolHe3_Last_Flip_Start : 16:08:11 10/16/2008
    haPolHe3_Last_Flip_End : 19:00:00 12/31/1903
    haPolHe3_FLIP_NMR_PHASE : 0
    haPolHe3_FLIP_NMR_Mag : 0
    haPolHe3_FLIP_NMR_Pol : 41.09
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : disabled
    HaGenTargPos : -9.38
    ----