     Run Number: 20546
     End of Run Comment:
    Run_type=Cosmics,target_type=Polarized 3He,targetpol_poldir=Transverse-in-plane,targetpol_pol=37.8,beam_e0=1.246,beam_raster=on,beam_halfwaveplate=in,rightarm_p=1.1759,rightarm_theta=-17,comment_text=hardcoded pedsuppression on for ROC8, empty pedestals
     
    
    PRESCALE FACTORS:ps1=7   ps2=40   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 7293         [++]: 3425         [--]: 0            [+-]: 0            [-+]: 3672         
    TIME     : [ 0]: 10.043 mins  [++]: 4.882 mins  [--]: 0.017 mins  [+-]: 0.017 mins  [-+]: 4.882 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =       303.98983 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:   0.07%      [++]:   3.16%      [--]:   0.00%      [+-]:   0.00%      [-+]:  -3.19%      
    
    TRIGGER RATES:   PRES/REAL ( T3 to T7 for PVDIS )
    T1[ 0] : 1.7/11.7 Hz   T2[ 0] : 0.2/7.7  Hz   T3[ 0] : 0.0/3.5  Hz   T4[ 0] : 0.0/0.5  Hz   T5[ 0] : 0.0/2.6  Hz   T6[ 0] : 0.0/0.4  Hz   T7[ 0] : 0.0/0.0  Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] : 1.6/11.5 Hz   T2[++] : 0.2/7.7  Hz   T3[++] : 0.0/3.5  Hz   T4[++] : 0.0/0.5  Hz   T5[++] : 0.0/2.5  Hz   T6[++] : 0.0/0.3  Hz   T7[++] : 0.0/0.0  Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] : 0.0/0.0  Hz   T2[--] : 0.0/0.0  Hz   T3[--] : 0.0/0.0  Hz   T4[--] : 0.0/0.0  Hz   T5[--] : 0.0/0.0  Hz   T6[--] : 0.0/0.0  Hz   T7[--] : 0.0/0.0  Hz   T8[--] : 0.0/0.0  Hz   
    T1[+-] : 0.0/0.0  Hz   T2[+-] : 0.0/0.0  Hz   T3[+-] : 0.0/0.0  Hz   T4[+-] : 0.0/0.0  Hz   T5[+-] : 0.0/0.0  Hz   T6[+-] : 0.0/0.0  Hz   T7[+-] : 0.0/0.0  Hz   T8[+-] : 0.0/0.0  Hz   
    T1[-+] : 1.7/12.0 Hz   T2[-+] : 0.2/7.7  Hz   T3[-+] : 0.0/3.5  Hz   T4[-+] : 0.0/0.5  Hz   T5[-+] : 0.0/2.6  Hz   T6[-+] : 0.0/0.4  Hz   T7[-+] : 0.0/0.0  Hz   T8[-+] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL ( T3 to T7 for PVDIS )
    T1[ 0] :   1011/7078     T2[ 0] :    116/4649     T3[ 0] :      0/2132     T4[ 0] :      0/301      T5[ 0] :      0/1541     T6[ 0] :      0/211      T7[ 0] :      0/0        T8[ 0] :   6170/617064   
    T1[++] :    480/3364     T2[++] :     56/2264     T3[++] :      0/1036     T4[++] :      0/147      T5[++] :      0/738      T6[++] :      0/100      T7[++] :      0/0        T8[++] :   2999/299953   
    T1[--] :      0/0        T2[--] :      0/0        T3[--] :      0/0        T4[--] :      0/0        T5[--] :      0/0        T6[--] :      0/0        T7[--] :      0/0        T8[--] :      0/0        
    T1[+-] :      0/0        T2[+-] :      0/0        T3[+-] :      0/0        T4[+-] :      0/0        T5[+-] :      0/0        T6[+-] :      0/0        T7[+-] :      0/0        T8[+-] :      0/0        
    T1[-+] :    503/3521     T2[-+] :     56/2254     T3[-+] :      0/1037     T4[-+] :      0/145      T5[-+] :      0/761      T6[-+] :      0/103      T7[-+] :      0/0        T8[-+] :   2999/299925   
    
    TRIGGER RATES (Unprescaled LHRS T3 and T4):   
    T3[ 0] : 8.5  T4[ 0] : 9.1  
    T3[++] : 8.5  T4[++] : 9.3  
    T3[--] : 0.0  T4[--] : 0.0  
    T3[+-] : 0.0  T4[+-] : 0.0  
    T3[-+] : 8.3  T4[-+] : 8.9  
    
    TRIGGER TOTALS (Unprescaled LHRS T3 and T4): 
    T3[ 0] :   5100  T4[ 0] :   5467  
    T3[++] :   2491  T4[++] :   2730  
    T3[--] :      0  T4[--] :      0  
    T3[+-] :      0  T4[+-] :      0  
    T3[-+] :   2442  T4[-+] :   2595  
    
    AVERAGE CURRENT
    BCM x1 : 0.0161 uA  BCM x3 : 0.0129 uA  BCM x10: 0.0199 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :    1E+06 ppm     BCM u3 :    1E+06 ppm     BCM u10:    1E+06 ppm     
    BCM d1 :    1E+06 ppm     BCM d3 :    1E+06 ppm     BCM d10:    1E+06 ppm     
    
    Target -
    BCM u1 :    1E+06 ppm     BCM u3 :    1E+06 ppm     BCM u10:    1E+06 ppm     
    BCM d1 :    1E+06 ppm     BCM d3 :    1E+06 ppm     BCM d10:    1E+06 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:4.809E-06      BCM u3 [ 0]:2.279E-06      BCM u10[ 0]:1.212E-05      
    BCM u1 [++]:2.341E-06      BCM u3 [++]:1.109E-06      BCM u10[++]:5.895E-06      
    BCM u1 [--]:0              BCM u3 [--]:0              BCM u10[--]:0              
    BCM u1 [+-]:0              BCM u3 [+-]:0              BCM u10[+-]:0              
    BCM u1 [-+]:2.334E-06      BCM u3 [-+]:1.106E-06      BCM u10[-+]:5.889E-06      
    
    BCM d1 [ 0]:1.458E-05      BCM d3 [ 0]:1.329E-05      BCM d10[ 0]:1.188E-05      
    BCM d1 [++]:7.123E-06      BCM d3 [++]:6.489E-06      BCM d10[++]:5.79E-06       
    BCM d1 [--]:0              BCM d3 [--]:0              BCM d10[--]:0              
    BCM d1 [+-]:0              BCM d3 [+-]:0              BCM d10[+-]:0              
    BCM d1 [-+]:7.055E-06      BCM d3 [-+]:6.427E-06      BCM d10[-+]:5.759E-06      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 20546 at Wed Apr 29 11:00:42 EDT 2009
    
    Wien angle : 74.8283
    Half-wave plate (off=out) : IN
    Right Arm D1 momentum : 1.1759
    Right Arm arm angle : 16.9999
    Left Arm D1 momentum : 1.17589
    Left Arm arm angle : 17.0054
    -----
    HALLA:p : 1245.25
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 1245.25
    -----
    Right Arm Top VDC Current : -3.66211
    Right Arm Bottom VDC Current : -3.125
    Right Arm Top VDC voltage : 4.00586
    Right Arm Bottom VDC voltage : 3.99561
    -----
    Left Arm Top VDC Current : -1.95312
    Left Arm Bottom VDC Current : 2.68555
    Left Arm Top VDC voltage : 3.99658
    Left Arm Bottom VDC voltage : 4
    -----
    Right Arm Q1 momentum : 1.17569
    Right Arm Q1 power supply : 883.986
    Right Arm Q1 gauss meter : -0.022108
    Right Arm Q2 power supply current : 506.062
    Right Arm Q2 momentum : 1.17588
    Right Arm Q2 gauss meter : 0.2651
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 402.936
    Right Arm D1 momentum : 1.1759
    Right Arm D1 NMR : 0.436364
    Right Arm Q3 power supply current : 467.903
    Right Arm Q3 momentum : 1.1759
    Right Arm Q3 gauss meter : 0.2089
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 518
    BigBite magnet current readback : 515.459
    BigBite Gaussmeter readback : -0.29713
    -----
    Average current of the two cavities : 0.0327443
    Current on Unser monitor : -6.3772
    Current on Upstream bcm : 0.0489044
    Current on Downstream bcm : 0.0165842
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 0.782654
    Hall C Current : 28.9108
    MBSY1c magnet current (amp) : 0.0377197
    MBSY1c Bdl : 310988
    Hall A momentum (Tiefenbach) (HALLA:p) : 1245.25
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 1246.8
    Hall A energy (halla_MeV) : 1245.25
    Hall C energy (hallc_MeV) : 5971.72
    Delta(E)/E width (MV_AI_DXWID) : 0.219282
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    HacR_HPE1313A:0_Ch58 : -0.599609
    HacR_HPE1313A:0_Ch55 : 22.6074
    HacR_HPE1313A:0_Ch54 : -0.94873
    Right Arm Angle Floor Angle : 17
    Right Arm Angle Vernier : -34.2
    Right Arm Scattering Angle : 16.9999
    Right VDC -DISC LVL Top : -5.0874
    Right VDC -DISC LVL Bottom : 4.96973
    Right VDC -DISC LVL Voltage1 : 3.875
    Right VDC -DISC LVL Voltage2 : 3.84277
    -----
    Wien angle : 74.8283
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1721.7
    Wien field : 49.863
    Laser attenuation Hall A : 150
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : -10.5973
    Target OTR y-position : 5
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.07205
    SLI vert. size mm : 0
    SLI y position : 0.585916
    -----
    Polarized 3He Target
    RTD1 (upstream) : 38.3105
    RTD2 : 49.8047
    RTD3 : 89.082
    RTD4 : 46.709
    RTD5 (downstream) : 39.4922
    RTD6 (pump cell up) : 250.195
    RTD7 (pump cell down) : 242.344
    HacAi_hpchan7: Temp at Ref. Cell : 37.7051
    HacAi_hpchan8: Temp at Ref. Cell : 41.1621
    HacAi_hpchan9: Temp at Ref. Cell : 37.7637
    Reference Cell Gas Pressure (psi) : -215.01
    Reference Cell System Vacuum (Torr) : -180.414
    Cooling Jets Flow Rate : 49.3652
    Target position : -9.38
    Oven Air Flow : 229.8
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : 230.0
    HacOMEGA_SP1 : 230
    HacOMEGA_PROP1 : 1000
    HacOMEGA_RST1 : 120
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 9
    CLASER_TEMP : 14
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 8
    CLASER3_TEMP : 23
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 8
    CLASER4_TEMP : 16
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 9
    CLASER5_TEMP : 19.2
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 9
    CLASER6_TEMP : 14
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0021
    ntc1_temp : 26.0348
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.002
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9961
    ntc3_temp : 25
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : -4.233
    DDM45_2disp1_read : 0.168184
    DDM45_3disp1_read : 5.512
    ----
    haPolHe3_Spin_State : 1
    haPolHe3_Flip_Sequence_ID : 352
    haPolHe3_Flip_Count : 23
    haPolHe3_EPR_ID : 4282138
    haPolHe3_EPR_POL : 75.7418
    haPolHe3_Last_Flip_Start : 10:31:49 4/29/2009
    haPolHe3_Last_Flip_End : 10:31:55 4/29/2009
    haPolHe3_FLIP_NMR_PHASE : 179.532
    haPolHe3_FLIP_NMR_Mag : 18.7047
    haPolHe3_FLIP_NMR_Pol : 38.1014
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : enabled
    HaGenTargPos : -9.38
    ----