     Run Number: 20572
     End of Run Comment:
    Run_type=Test,target_type=Polarized 3He,targetpol_poldir=Transverse-in-plane,targetpol_pol=37.8,beam_e0=1.246,beam_raster=on,beam_halfwaveplate=in,rightarm_p=1.1759,rightarm_theta=-17,comment_text=spot++
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 982          [++]: 468          [--]: 0            [+-]: 501          [-+]: 0            
    TIME     : [ 0]: 1.598 mins  [++]: 0.788 mins  [--]: 0.017 mins  [+-]: 0.787 mins  [-+]: 0.017 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        46.85157 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:  -0.02%      [++]:   3.30%      [--]:   0.00%      [+-]:  -3.57%      [-+]:   0.00%      
    
    TRIGGER RATES:   PRES/REAL ( T3 to T7 for PVDIS )
    T1[ 0] : 0.0/117.4 Hz   T2[ 0] : 0.0/13.9 Hz   T3[ 0] : 0.0/33.3 Hz   T4[ 0] : 0.0/19.0 Hz   T5[ 0] : 0.0/37.2 Hz   T6[ 0] : 0.0/22.7 Hz   T7[ 0] : 0.0/0.0  Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] : 0.0/116.7 Hz   T2[++] : 0.0/13.3 Hz   T3[++] : 0.0/33.2 Hz   T4[++] : 0.0/20.0 Hz   T5[++] : 0.0/37.5 Hz   T6[++] : 0.0/22.6 Hz   T7[++] : 0.0/0.0  Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] : 0.0/0.0  Hz   T2[--] : 0.0/0.0  Hz   T3[--] : 0.0/0.0  Hz   T4[--] : 0.0/0.0  Hz   T5[--] : 0.0/0.0  Hz   T6[--] : 0.0/0.0  Hz   T7[--] : 0.0/0.0  Hz   T8[--] : 0.0/0.0  Hz   
    T1[+-] : 0.0/117.9 Hz   T2[+-] : 0.0/14.5 Hz   T3[+-] : 0.0/33.3 Hz   T4[+-] : 0.0/18.1 Hz   T5[+-] : 0.0/36.9 Hz   T6[+-] : 0.0/22.8 Hz   T7[+-] : 0.0/0.0  Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] : 0.0/0.0  Hz   T2[-+] : 0.0/0.0  Hz   T3[-+] : 0.0/0.0  Hz   T4[-+] : 0.0/0.0  Hz   T5[-+] : 0.0/0.0  Hz   T6[-+] : 0.0/0.0  Hz   T7[-+] : 0.0/0.0  Hz   T8[-+] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL ( T3 to T7 for PVDIS )
    T1[ 0] :      0/11260    T2[ 0] :      0/1328     T3[ 0] :      0/3190     T4[ 0] :      0/1826     T5[ 0] :      0/3564     T6[ 0] :      0/2180     T7[ 0] :      0/0        T8[ 0] :    981/98172    
    T1[++] :      0/5513     T2[++] :      0/627      T3[++] :      0/1567     T4[++] :      0/946      T5[++] :      0/1770     T6[++] :      0/1070     T7[++] :      0/0        T8[++] :    483/48394    
    T1[--] :      0/0        T2[--] :      0/0        T3[--] :      0/0        T4[--] :      0/0        T5[--] :      0/0        T6[--] :      0/0        T7[--] :      0/0        T8[--] :      0/0        
    T1[+-] :      0/5571     T2[+-] :      0/683      T3[+-] :      0/1575     T4[+-] :      0/856      T5[+-] :      0/1744     T6[+-] :      0/1078     T7[+-] :      0/0        T8[+-] :    483/48369    
    T1[-+] :      0/0        T2[-+] :      0/0        T3[-+] :      0/0        T4[-+] :      0/0        T5[-+] :      0/0        T6[-+] :      0/0        T7[-+] :      0/0        T8[-+] :      0/0        
    
    TRIGGER RATES (Unprescaled LHRS T3 and T4):   
    T3[ 0] :144.4  T4[ 0] :14.5  
    T3[++] :142.9  T4[++] :13.9  
    T3[--] : 0.0  T4[--] : 0.0  
    T3[+-] :145.0  T4[+-] :15.0  
    T3[-+] : 0.0  T4[-+] : 0.0  
    
    TRIGGER TOTALS (Unprescaled LHRS T3 and T4): 
    T3[ 0] :  13842  T4[ 0] :   1391  
    T3[++] :   6754  T4[++] :    656  
    T3[--] :      0  T4[--] :      0  
    T3[+-] :   6848  T4[+-] :    709  
    T3[-+] :      0  T4[-+] :      0  
    
    AVERAGE CURRENT
    BCM x1 : 1.6630 uA  BCM x3 : 1.6681 uA  BCM x10: 1.5705 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :    738.7 ppm     BCM u3 :    628.1 ppm     BCM u10:    585.8 ppm     
    BCM d1 :    971.3 ppm     BCM d3 :     1874 ppm     BCM d10:      586 ppm     
    
    Target -
    BCM u1 :    1E+39 ppm     BCM u3 :    1E+39 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :    1E+39 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:0.0001595      BCM u3 [ 0]:0.000159       BCM u10[ 0]:0.000142       
    BCM u1 [++]:7.864E-05      BCM u3 [++]:7.838E-05      BCM u10[++]:6.999E-05      
    BCM u1 [--]:0              BCM u3 [--]:0              BCM u10[--]:0              
    BCM u1 [+-]:7.853E-05      BCM u3 [+-]:7.828E-05      BCM u10[+-]:6.991E-05      
    BCM u1 [-+]:0              BCM u3 [-+]:0              BCM u10[-+]:0              
    
    BCM d1 [ 0]:0.0001594      BCM d3 [ 0]:0.0001608      BCM d10[ 0]:0.0001591      
    BCM d1 [++]:7.859E-05      BCM d3 [++]:7.892E-05      BCM d10[++]:7.844E-05      
    BCM d1 [--]:0              BCM d3 [--]:0              BCM d10[--]:0              
    BCM d1 [+-]:7.843E-05      BCM d3 [+-]:7.863E-05      BCM d10[+-]:7.834E-05      
    BCM d1 [-+]:0              BCM d3 [-+]:0              BCM d10[-+]:0              
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 20572 at Wed Apr 29 23:52:37 EDT 2009
    
    Wien angle : 74.8283
    Half-wave plate (off=out) : IN
    Right Arm D1 momentum : 3.08545
    Right Arm arm angle : 16.9999
    Left Arm D1 momentum : 3.08554
    Left Arm arm angle : 17.0054
    -----
    HALLA:p : 3605.66
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 3605.66
    -----
    Right Arm Top VDC Current : 1.07422
    Right Arm Bottom VDC Current : 0.341797
    Right Arm Top VDC voltage : 4.00488
    Right Arm Bottom VDC voltage : 3.99316
    -----
    Left Arm Top VDC Current : -1.2207
    Left Arm Bottom VDC Current : -1.46484
    Left Arm Top VDC voltage : 3.99463
    Left Arm Bottom VDC voltage : 3.99902
    -----
    Right Arm Q1 momentum : 3.08535
    Right Arm Q1 power supply : 2319.98
    Right Arm Q1 gauss meter : -0.05758
    Right Arm Q2 power supply current : 1327.66
    Right Arm Q2 momentum : 3.08493
    Right Arm Q2 gauss meter : 0.6941
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 1112.79
    Right Arm D1 momentum : 3.08545
    Right Arm D1 NMR : 1.14497
    Right Arm Q3 power supply current : 1227.65
    Right Arm Q3 momentum : 3.08526
    Right Arm Q3 gauss meter : 0.5491
    Right Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 518
    BigBite magnet current readback : 515.459
    BigBite Gaussmeter readback : -0.29713
    -----
    Average current of the two cavities : 0.0353309
    Current on Unser monitor : -7.31358
    Current on Upstream bcm : 0.0511984
    Current on Downstream bcm : 0.0194634
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 4.61232
    Hall C Current : 30.1072
    MBSY1c magnet current (amp) : 150.449
    MBSY1c Bdl : 901351
    Hall A momentum (Tiefenbach) (HALLA:p) : 3605.66
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 3607.6
    Hall A energy (halla_MeV) : 3605.66
    Hall C energy (hallc_MeV) : 5971.72
    Delta(E)/E width (MV_AI_DXWID) : 0.219282
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 1.97033
    IPM1H04B.XPOS : -0.51033
    IPM1H04B.YPOS : 2.01135
    -----
    HacR_HPE1313A:0_Ch58 : -0.597656
    HacR_HPE1313A:0_Ch55 : 22.998
    HacR_HPE1313A:0_Ch54 : -0.94043
    Right Arm Angle Floor Angle : 17
    Right Arm Angle Vernier : -34.2
    Right Arm Scattering Angle : 16.9999
    Right VDC -DISC LVL Top : -5.08496
    Right VDC -DISC LVL Bottom : 4.97363
    Right VDC -DISC LVL Voltage1 : 3.87354
    Right VDC -DISC LVL Voltage2 : 3.84082
    -----
    Wien angle : 74.8283
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1720
    Wien field : 49.863
    Laser attenuation Hall A : 110
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : -10.5973
    Target OTR y-position : 5
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.38634
    SLI vert. size mm : 0
    SLI y position : 2.06573
    -----
    Polarized 3He Target
    RTD1 (upstream) : 38.9551
    RTD2 : 50.5469
    RTD3 : 90.6152
    RTD4 : 48.3008
    RTD5 (downstream) : 40.4102
    RTD6 (pump cell up) : 246.973
    RTD7 (pump cell down) : 242.637
    HacAi_hpchan7: Temp at Ref. Cell : 38.3594
    HacAi_hpchan8: Temp at Ref. Cell : 42.4902
    HacAi_hpchan9: Temp at Ref. Cell : 38.4473
    Reference Cell Gas Pressure (psi) : -214.213
    Reference Cell System Vacuum (Torr) : -175.657
    Cooling Jets Flow Rate : 50.7751
    Target position : -9.38
    Oven Air Flow : 230.1
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : 230.0
    HacOMEGA_SP1 : 230
    HacOMEGA_PROP1 : 1000
    HacOMEGA_RST1 : 120
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 9
    CLASER_TEMP : 14
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 8
    CLASER3_TEMP : 23
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 8
    CLASER4_TEMP : 16
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 9
    CLASER5_TEMP : 19.2
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 9
    CLASER6_TEMP : 14
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0021
    ntc1_temp : 26.0367
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.001
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9961
    ntc3_temp : 25
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : 0.022
    DDM45_2disp1_read : 13.0198
    DDM45_3disp1_read : -0.219
    ----
    haPolHe3_Spin_State : 1
    haPolHe3_Flip_Sequence_ID : 354
    haPolHe3_Flip_Count : 14
    haPolHe3_EPR_ID : 4282138
    haPolHe3_EPR_POL : 75.7418
    haPolHe3_Last_Flip_Start : 23:34:18 4/29/2009
    haPolHe3_Last_Flip_End : 23:34:29 4/29/2009
    haPolHe3_FLIP_NMR_PHASE : 178.264
    haPolHe3_FLIP_NMR_Mag : 22.298
    haPolHe3_FLIP_NMR_Pol : 84.6208
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : enabled
    HaGenTargPos : -9.38
    ----