User name R. Michaels
Log entry time 16:18:17 on April 30, 2009
Entry number 269967
This entry is a followup to: 269908
keyword=happex7 blaster test
During the Moller we did blaster tests on happex7 crate.
As suspected it has only 4 kbyte/sec !!
I think this crate pumps out about 85 bytes per event,
so at 30 Hz that is about 2.5 kbyte/sec and you get no deadtime. Barely !
Recommend to power-cycle (or hard reset) this crate.
If that does not help, may need independent network cable, as stated
before. Simply rebooting did not help.
A note: TS0 (also through this netgear switch) has 11 Mbyte/sec.
So the R-HRS DAQ is ok. (I guess you would have noticed !)
A copy of this log entry has been emailed to: moffit