Privacy and Security Notice

End_of_Run_1706


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 19:56:58 on April 30, 2009

    Entry number 270033

    keyword=End_of_Run_1706
    ****************************
     Run Number: 1706
     End of Run Comment:
    Run_type=Production,target_type=Polarized 3He,targetpol_poldir=Vertical,targetpol_pol=64.8,beam_e0=3.605,beam_raster=on,beam_halfwaveplate=in,leftarm_p=3.0855,leftarm_theta=17.0,leftarm_sieve=out,bbarm_i=10 micro,bbarm_theta=71,bbarm_sieve=out,bbarm_zoff=0,comment_text=Production
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=16777215   ps3=1   ps4=1   ps5=65535   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 1002893      [++]: 226550       [--]: 266906       [+-]: 226377       [-+]: 266505       
    TIME     : [ 0]: 21.029 mins  [++]: 5.011 mins  [--]: 5.343 mins  [+-]: 5.015 mins  [-+]: 5.346 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =       630.32643 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:   6.12%      [++]:   6.01%      [--]:   6.14%      [+-]:   5.96%      [-+]:   6.28%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] : 0.0/0.0  Hz   T2[ 0] : 0.0/0.0  Hz   T3[ 0] :789.8/789.8 Hz   T4[ 0] :46.7/46.7 Hz   T5[ 0] : 0.0/0.0  Hz   T6[ 0] : 0.0/0.0  Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] : 0.0/0.0  Hz   T2[++] : 0.0/0.0  Hz   T3[++] :747.2/747.2 Hz   T4[++] :44.3/44.3 Hz   T5[++] : 0.0/0.0  Hz   T6[++] : 0.0/0.0  Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] : 0.0/0.0  Hz   T2[--] : 0.0/0.0  Hz   T3[--] :827.8/827.8 Hz   T4[--] :49.1/49.1 Hz   T5[--] : 0.0/0.0  Hz   T6[--] : 0.0/0.0  Hz   T8[--] :10.2/1024.0 Hz   
    T1[+-] : 0.0/0.0  Hz   T2[+-] : 0.0/0.0  Hz   T3[+-] :745.4/745.4 Hz   T4[+-] :44.5/44.5 Hz   T5[+-] : 0.0/0.0  Hz   T6[+-] : 0.0/0.0  Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] : 0.0/0.0  Hz   T2[-+] : 0.0/0.0  Hz   T3[-+] :827.8/827.8 Hz   T4[-+] :48.7/48.7 Hz   T5[-+] : 0.0/0.0  Hz   T6[-+] : 0.0/0.0  Hz   T8[-+] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] :      0/0        T2[ 0] :      0/0        T3[ 0] : 996497/996497   T4[ 0] :  58968/58968    T5[ 0] :      0/0        T6[ 0] :      0/0        T8[ 0] :  12919/1291992  
    T1[++] :      0/0        T2[++] :      0/0        T3[++] : 224672/224672   T4[++] :  13312/13312    T5[++] :      0/0        T6[++] :      0/0        T8[++] :   3078/307897   
    T1[--] :      0/0        T2[--] :      0/0        T3[--] : 265383/265383   T4[--] :  15727/15727    T5[--] :      0/0        T6[--] :      0/0        T8[--] :   3282/328287   
    T1[+-] :      0/0        T2[+-] :      0/0        T3[+-] : 224282/224282   T4[+-] :  13394/13394    T5[+-] :      0/0        T6[+-] :      0/0        T8[+-] :   3080/308097   
    T1[-+] :      0/0        T2[-+] :      0/0        T3[-+] : 265513/265513   T4[-+] :  15606/15606    T5[-+] :      0/0        T6[-+] :      0/0        T8[-+] :   3284/328431   
    
    TRIGGER RATES (Unprescaled RHRS T1 and T2):   
    T1[ 0] :622.1  T2[ 0] :50.9  
    T1[++] :589.3  T2[++] :49.1  
    T1[--] :652.6  T2[--] :51.9  
    T1[+-] :587.5  T2[+-] :48.6  
    T1[-+] :651.7  T2[-+] :53.7  
    
    TRIGGER TOTALS (Unprescaled RHRS T1 and T2): 
    T1[ 0] : 784961  T2[ 0] :  64263  
    T1[++] : 177186  T2[++] :  14770  
    T1[--] : 209213  T2[--] :  16635  
    T1[+-] : 176764  T2[+-] :  14632  
    T1[-+] : 209023  T2[-+] :  17231  
    
    AVERAGE CURRENT
    BCM x1 : 9.5436 uA  BCM x3 : 9.5393 uA  BCM x10: 8.9843 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :   -164.1 ppm     BCM u3 :   -210.5 ppm     BCM u10:   -204.2 ppm     
    BCM d1 :   -209.6 ppm     BCM d3 :     -213 ppm     BCM d10:   -204.7 ppm     
    
    Target -
    BCM u1 :   -87.56 ppm     BCM u3 :  -0.4184 ppm     BCM u10:    3.923 ppm     
    BCM d1 :   -133.5 ppm     BCM d3 :   -3.015 ppm     BCM d10:   -73.05 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:0.01212        BCM u3 [ 0]:0.01212        BCM u10[ 0]:0.01072        
    BCM u1 [++]:0.002735       BCM u3 [++]:0.002731       BCM u10[++]:0.002416       
    BCM u1 [--]:0.003227       BCM u3 [--]:0.003226       BCM u10[--]:0.002855       
    BCM u1 [+-]:0.002736       BCM u3 [+-]:0.002732       BCM u10[+-]:0.002417       
    BCM u1 [-+]:0.003226       BCM u3 [-+]:0.003226       BCM u10[-+]:0.002855       
    
    BCM d1 [ 0]:0.01196        BCM d3 [ 0]:0.01196        BCM d10[ 0]:0.01195        
    BCM d1 [++]:0.002695       BCM d3 [++]:0.002694       BCM d10[++]:0.002693       
    BCM d1 [--]:0.003184       BCM d3 [--]:0.003184       BCM d10[--]:0.003184       
    BCM d1 [+-]:0.002696       BCM d3 [+-]:0.002696       BCM d10[+-]:0.002694       
    BCM d1 [-+]:0.003183       BCM d3 [-+]:0.003184       BCM d10[-+]:0.003183       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1706 at Thu Apr 30 19:56:50 EDT 2009
    
    Wien angle : 74.8283
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 3.08552
    Left Arm arm angle : 17.0054
    Right Arm D1 momentum : 3.0855
    Right Arm arm angle : 16.9999
    -----
    HALLA:p : 3605.57
    HALLA:dpp : -2.44162e-05
    Tiefenbach Hall A energy : 3605.57
    Left Arm Top VDC Current : -1.95312
    Left Arm Bottom VDC Current : -0.830078
    Left Arm Top VDC voltage : 3.99805
    Left Arm Bottom VDC voltage : 4.00049
    -----
    Right Arm Top VDC Current : -1.80664
    Right Arm Bottom VDC Current : 0.195312
    Right Arm Top VDC voltage : 4.00537
    Right Arm Bottom VDC voltage : 3.99316
    -----
    Left Arm Q1 momentum : 3.08585
    Left Arm Q1 power supply : 2321.58
    Left Arm Q1 gauss meter : -0.19579
    Left Arm Q2 gauss meter : 0.6979
    Left Arm Q2 power supply current : 1328.4
    Left Arm Q2 momentum : 3.08499
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1082.09
    Left Arm D1 momentum : 3.08552
    Left Arm D1 NMR : 1.14257
    Left Arm Q3 gauss meter : -0.61945
    Left Arm Q3 power supply current : 1228.37
    Left Arm Q3 momentum : 3.08543
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 518
    BigBite magnet current readback : 515.459
    BigBite Gaussmeter readback : -0.29713
    -----
    Average current of the two cavities : 9.96921
    Current on Unser monitor : 2.67667
    Current on Upstream bcm : 10.0352
    Current on Downstream bcm : 9.90321
    Upstream Cavity Coefficient : 48.345
    Downstream Cavity Coefficient : 47.773
    Current on IBC0L02 (source) : 12.7694
    Hall C Current : 29.1094
    MBSY1c magnet current (amp) : 150.449
    MBSY1c Bdl : 901351
    Hall A momentum (Tiefenbach) (HALLA:p) : 3605.59
    Hall A momentum orbit correction (dpp) : -1.70837e-05
    Hall A setup momentum (MMSHLAE) : 3607.6
    Hall A energy (halla_MeV) : 3605.59
    Hall C energy (hallc_MeV) : 5971.72
    Delta(E)/E width (MV_AI_DXWID) : 0.219282
    IPM1C12.XPOS : 0.0056951
    IPM1H04A.XPOS : -0.541075
    IPM1H04A.YPOS : 1.98269
    IPM1H04B.XPOS : -0.542954
    IPM1H04B.YPOS : 2.00784
    -----
    HacL_HPE1313A:0_Ch58 : -0.151855
    HacL_HPE1313A:0_Ch55 : 24.5605
    HacL_HPE1313A:0_Ch54 : -0.00488281
    Left Arm Angle Vernier : 32
    Left Arm Scattering Angle : 17.0054
    Left VDC -DISC LVL Top : 3.89795
    Left VDC -DISC LVL Bottom : 3.96777
    Left VDC -DISC LVL Voltage1 : 4.97412
    Left VDC -DISC LVL Voltage2 : -5.05713
    -----
    Wien angle : 74.8283
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1720
    Wien field : 49.863
    Laser attenuation Hall A : 205
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : -10.5973
    Target OTR y-position : 5
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.79627
    SLI vert. size mm : 0
    SLI y position : 3.10986
    -----
    Polarized 3He Target
    RTD1 (upstream) : 41.1133
    RTD2 : 53.5059
    RTD3 : 93.7109
    RTD4 : 50.8301
    RTD5 (downstream) : 42.1191
    RTD6 (pump cell up) : 246.68
    RTD7 (pump cell down) : 242.52
    HacAi_hpchan7: Temp at Ref. Cell : 38.7109
    HacAi_hpchan8: Temp at Ref. Cell : 42.9004
    HacAi_hpchan9: Temp at Ref. Cell : 38.8379
    Reference Cell Gas Pressure (psi) : -211.514
    Reference Cell System Vacuum (Torr) : -178.849
    Cooling Jets Flow Rate : 49.7864
    Target position : -9.38
    Oven Air Flow : 229.9
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : 229.5
    HacOMEGA_SP1 : 230
    HacOMEGA_PROP1 : 1000
    HacOMEGA_RST1 : 120
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 9
    CLASER_TEMP : 14
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 8
    CLASER3_TEMP : 23
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 8
    CLASER4_TEMP : 16
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 9
    CLASER5_TEMP : 19.2
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 9
    CLASER6_TEMP : 14
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0031
    ntc1_temp : 26.0367
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.001
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9961
    ntc3_temp : 25
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : 0.022
    DDM45_2disp1_read : 13.0198
    DDM45_3disp1_read : -0.218
    ----
    haPolHe3_Spin_State : 1
    haPolHe3_Flip_Sequence_ID : 355
    haPolHe3_Flip_Count : 5
    haPolHe3_EPR_ID : 4282138
    haPolHe3_EPR_POL : 75.7418
    haPolHe3_Last_Flip_Start : 19:46:05 4/30/2009
    haPolHe3_Last_Flip_End : 19:46:11 4/30/2009
    haPolHe3_FLIP_NMR_PHASE : 178.264
    haPolHe3_FLIP_NMR_Mag : 23.4453
    haPolHe3_FLIP_NMR_Pol : 64.3338
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : enabled
    HaGenTargPos : -9.38
    ----