    Moller results on May 27 13:00-16:00


    Preliminary results for Half Wave Plane = IN
     #    Wien angle  beam     runs target Ptarget% Pbeam% comments
    1 66.92° 0.7 µA 13349-13353 5 8.03 88.86±0.2±2.0
    2 66.92° 0.7 µA 13354-13357 4 7.51 87.69±0.2±2.0
    Aver. 66.92° 0.7 µA - 4-5 - 88.34±0.2±2.0 Targets 4 and 5

    Preliminary results fo Half Wave Plate = OUT
     #    Wien angle  beam     runs target Ptarget% Pbeam% comments
    1 66.92° 0.7 µA 13358-13361 4 8.03 86.96±0.2±2.0
    2 66.92° 0.7 µA 13362-13365 5 7.51 87.62±0.2±2.0
    Aver. 66.92° 0.7 µA - 4-5 - 87.29±0.2±2.0 Targets 4 and 5


    Later we did a series of short runs with alternating halfwave plate state.
    Will be posted later.