Privacy and Security Notice

End_of_Run_2994


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 07:41:26 on May 31, 2009

    Entry number 277836

    keyword=End_of_Run_2994
    ****************************
     Run Number: 2994
     End of Run Comment:
    Run_type=Production,target_type=Polarized 3He,targetpol_poldir=Longitudinal,targetpol_pol=56.7%,beam_e0=2.425,beam_raster=on,beam_halfwaveplate=out,leftarm_p=2.277,leftarm_theta=14.5,leftarm_sieve=out,bbarm_i=518,bbarm_theta=82,bbarm_sieve=out,bbarm_zoff=0,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=16777215   ps3=5   ps4=4   ps5=1   ps6=1   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 4008506      [++]: 1975243      [--]: 0            [+-]: 1974065      [-+]: 0            
    TIME     : [ 0]: 27.084 mins  [++]: 13.325 mins  [--]: 0.017 mins  [+-]: 13.342 mins  [-+]: 0.017 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =       811.21977 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:   4.49%      [++]:   4.33%      [--]:   0.00%      [+-]:   4.51%      [-+]:   0.00%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] : 0.0/306549.6 Hz   T2[ 0] : 0.0/272841.8 Hz   T3[ 0] :2026.0/10129.8 Hz   T4[ 0] :50.4/201.5 Hz   T5[ 0] :747.1/747.1 Hz   T6[ 0] :507.8/507.8 Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] : 0.0/305364.8 Hz   T2[++] : 0.0/272153.2 Hz   T3[++] :2026.9/10134.6 Hz   T4[++] :50.4/201.7 Hz   T5[++] :745.2/745.2 Hz   T6[++] :507.0/507.0 Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] : 0.0/0.0  Hz   T2[--] : 0.0/0.0  Hz   T3[--] : 0.0/0.0  Hz   T4[--] : 0.0/0.0  Hz   T5[--] : 0.0/0.0  Hz   T6[--] : 0.0/0.0  Hz   T8[--] : 0.0/0.0  Hz   
    T1[+-] : 0.0/307614.2 Hz   T2[+-] : 0.0/273467.1 Hz   T3[+-] :2024.7/10123.4 Hz   T4[+-] :50.3/201.3 Hz   T5[+-] :748.9/748.9 Hz   T6[+-] :508.7/508.7 Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] : 0.0/0.0  Hz   T2[-+] : 0.0/0.0  Hz   T3[-+] : 0.0/0.0  Hz   T4[-+] : 0.0/0.0  Hz   T5[-+] : 0.0/0.0  Hz   T6[-+] : 0.0/0.0  Hz   T8[-+] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] :     29/498160750  T2[ 0] :     26/443383684  T3[ 0] :3292298/16461490  T4[ 0] :  81872/327488   T5[ 0] :1214015/1214015  T6[ 0] : 825170/825170   T8[ 0] :  16640/1664059  
    T1[++] :     14/244146306  T2[++] :     12/217592833  T3[++] :1620568/8102844  T4[++] :  40319/161276   T5[++] : 595808/595808   T6[++] : 405351/405351   T8[++] :   8187/818712   
    T1[--] :      0/0        T2[--] :      0/0        T3[--] :      0/0        T4[--] :      0/0        T5[--] :      0/0        T6[--] :      0/0        T8[--] :      0/0        
    T1[+-] :     14/246251201  T2[+-] :     13/218915784  T3[+-] :1620790/8103950  T4[+-] :  40293/161174   T5[+-] : 599518/599518   T6[+-] : 407185/407185   T8[+-] :   8197/819732   
    T1[-+] :      0/0        T2[-+] :      0/0        T3[-+] :      0/0        T4[-+] :      0/0        T5[-+] :      0/0        T6[-+] :      0/0        T8[-+] :      0/0        
    
    TRIGGER RATES (Unprescaled RHRS T1 and T2):   
    T1[ 0] :2002.3  T2[ 0] :58.3  
    T1[++] :2005.1  T2[++] :58.2  
    T1[--] : 0.0  T2[--] : 0.0  
    T1[+-] :1998.6  T2[+-] :58.2  
    T1[-+] : 0.0  T2[-+] : 0.0  
    
    TRIGGER TOTALS (Unprescaled RHRS T1 and T2): 
    T1[ 0] :3253818  T2[ 0] :  94702  
    T1[++] :1603128  T2[++] :  46571  
    T1[--] :      0  T2[--] :      0  
    T1[+-] :1599934  T2[+-] :  46601  
    T1[-+] :      0  T2[-+] :      0  
    
    AVERAGE CURRENT
    BCM x1 : 11.6048uA  BCM x3 : 11.6039uA  BCM x10: 10.9281uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :   -584.9 ppm     BCM u3 :     -699 ppm     BCM u10:   -692.5 ppm     
    BCM d1 :     -656 ppm     BCM d3 :   -761.1 ppm     BCM d10:     -694 ppm     
    
    Target -
    BCM u1 :    1E+39 ppm     BCM u3 :    1E+39 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :    1E+39 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:0.019          BCM u3 [ 0]:0.01899        BCM u10[ 0]:0.0168         
    BCM u1 [++]:0.009347       BCM u3 [++]:0.009341       BCM u10[++]:0.008262       
    BCM u1 [--]:0              BCM u3 [--]:0              BCM u10[--]:0              
    BCM u1 [+-]:0.009358       BCM u3 [+-]:0.009354       BCM u10[+-]:0.008274       
    BCM u1 [-+]:0              BCM u3 [-+]:0              BCM u10[-+]:0              
    
    BCM d1 [ 0]:0.01872        BCM d3 [ 0]:0.01872        BCM d10[ 0]:0.01872        
    BCM d1 [++]:0.009208       BCM d3 [++]:0.009211       BCM d10[++]:0.00921        
    BCM d1 [--]:0              BCM d3 [--]:0              BCM d10[--]:0              
    BCM d1 [+-]:0.00922        BCM d3 [+-]:0.009225       BCM d10[+-]:0.009223       
    BCM d1 [-+]:0              BCM d3 [-+]:0              BCM d10[-+]:0              
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2994 at Sun May 31 07:41:16 EDT 2009
    
    Wien angle : 66.9203
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 2.27701
    Left Arm arm angle : 14.4997
    Right Arm D1 momentum : 2.17504
    Right Arm arm angle : 17.9982
    -----
    HALLA:p : 2425.49
    HALLA:dpp : -1.34044e-05
    Tiefenbach Hall A energy : 2425.49
    Left Arm Top VDC Current : -2.24609
    Left Arm Bottom VDC Current : 3.41797
    Left Arm Top VDC voltage : 3.99268
    Left Arm Bottom VDC voltage : 4
    -----
    Right Arm Top VDC Current : -1.51367
    Right Arm Bottom VDC Current : 1.12305
    Right Arm Top VDC voltage : -0.0131836
    Right Arm Bottom VDC voltage : 4.00781
    -----
    Left Arm Q1 momentum : 2.27723
    Left Arm Q1 power supply : 1713.23
    Left Arm Q1 gauss meter : -0.14445
    Left Arm Q2 gauss meter : 0.5156
    Left Arm Q2 power supply current : 980.386
    Left Arm Q2 momentum : 2.27679
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 777.793
    Left Arm D1 momentum : 2.27701
    Left Arm D1 NMR : 0.842565
    Left Arm Q3 gauss meter : -0.45734
    Left Arm Q3 power supply current : 906.415
    Left Arm Q3 momentum : 2.27675
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 518
    BigBite magnet current readback : 515.459
    BigBite Gaussmeter readback : -0.3202
    -----
    Average current of the two cavities : 11.474
    Current on Unser monitor : 5.07823
    Current on Upstream bcm : 11.5108
    Current on Downstream bcm : 11.4373
    Upstream Cavity Coefficient : 44.3
    Downstream Cavity Coefficient : 43.49
    Current on IBC0L02 (source) : 11.386
    Hall C Current : 0
    MBSY1c magnet current (amp) : 101.081
    MBSY1c Bdl : 606094
    Hall A momentum (Tiefenbach) (HALLA:p) : 2425.49
    Hall A momentum orbit correction (dpp) : -1.16879e-05
    Hall A setup momentum (MMSHLAE) : 2427.2
    Hall A energy (halla_MeV) : 2425.49
    Hall C energy (hallc_MeV) : 5971.72
    Delta(E)/E width (MV_AI_DXWID) : 0.559797
    IPM1C12.XPOS : -0.0211018
    IPM1H04A.XPOS : -0.499528
    IPM1H04A.YPOS : 2.16366
    IPM1H04B.XPOS : -0.507036
    IPM1H04B.YPOS : 1.99323
    -----
    HacL_HPE1313A:0_Ch58 : -0.195801
    HacL_HPE1313A:0_Ch55 : 23.1934
    HacL_HPE1313A:0_Ch54 : 0.0322266
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 14.4997
    Left VDC -DISC LVL Top : 3.89551
    Left VDC -DISC LVL Bottom : 3.96143
    Left VDC -DISC LVL Voltage1 : 4.97412
    Left VDC -DISC LVL Voltage2 : -5.05811
    -----
    Wien angle : 66.9203
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1537
    Wien field : 44.582
    Laser attenuation Hall A : 251
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : -10.5973
    Target OTR y-position : 5
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.60124
    SLI vert. size mm : 0
    SLI y position : 2.17089
    -----
    Polarized 3He Target
    RTD1 (upstream) : 78.5059
    RTD2 : 46.1914
    RTD3 : 40.1953
    RTD4 : 41.377
    RTD5 (downstream) : 51.6504
    RTD6 (pump cell up) : 224.59
    RTD7 (pump cell down) : 250.723
    HacAi_hpchan7: Temp at Ref. Cell : -100
    HacAi_hpchan8: Temp at Ref. Cell : -20.1562
    HacAi_hpchan9: Temp at Ref. Cell : -21.1328
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -9.37
    Oven Air Flow : 230.6
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : 230.5
    HacOMEGA_SP1 : 230
    HacOMEGA_PROP1 : 30000
    HacOMEGA_RST1 : 600
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 9
    CLASER_TEMP : 14
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 8
    CLASER3_TEMP : 23
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 8
    CLASER4_TEMP : 16
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 9
    CLASER5_TEMP : 19.2
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 9
    CLASER6_TEMP : 14
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0011
    ntc1_temp : 26.0367
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.003
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9961
    ntc3_temp : 25
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : 5.642
    DDM45_2disp1_read : 0.168184
    DDM45_3disp1_read : 4.1
    ----
    haPolHe3_Spin_State : 0
    haPolHe3_Flip_Sequence_ID : 36
    haPolHe3_Flip_Count : 0
    haPolHe3_EPR_ID : 0
    haPolHe3_EPR_POL : 0
    haPolHe3_Last_Flip_Start : 16:08:11 10/16/2008
    haPolHe3_Last_Flip_End : 20:00:00 12/31/1903
    haPolHe3_FLIP_NMR_PHASE : 0
    haPolHe3_FLIP_NMR_Mag : 0
    haPolHe3_FLIP_NMR_Pol : 61.5985
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : enabled
    HaGenTargPos : -9.37
    ----