Privacy and Security Notice

End_of_Run_3008


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 13:55:18 on May 31, 2009

    Entry number 277923

    keyword=End_of_Run_3008
    ****************************
     Run Number: 3008
     End of Run Comment:
    Run_type=Production,target_type=Polarized 3He,targetpol_poldir=Longitudinal,targetpol_pol=61.6,beam_e0=2.425,beam_raster=on,beam_halfwaveplate=in,leftarm_p=2.277,leftarm_theta=14.5,leftarm_sieve=out,bbarm_i=518,bbarm_theta=82,bbarm_sieve=out,bbarm_zoff=0,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=16777215   ps3=5   ps4=4   ps5=1   ps6=1   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 4009676      [++]: 1975743      [--]: 0            [+-]: 1974594      [-+]: 0            
    TIME     : [ 0]: 27.814 mins  [++]: 13.685 mins  [--]: 0.017 mins  [+-]: 13.701 mins  [-+]: 0.017 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =       833.09200 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:   7.23%      [++]:   7.06%      [--]:   0.00%      [+-]:   7.27%      [-+]:   0.00%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] : 0.0/307347.0 Hz   T2[ 0] : 0.0/273292.7 Hz   T3[ 0] :2032.6/10162.9 Hz   T4[ 0] :50.6/202.2 Hz   T5[ 0] :747.7/747.7 Hz   T6[ 0] :508.0/508.0 Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] : 0.0/306142.5 Hz   T2[++] : 0.0/272575.4 Hz   T3[++] :2033.1/10165.6 Hz   T4[++] :50.8/203.1 Hz   T5[++] :745.5/745.5 Hz   T6[++] :507.6/507.6 Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] : 0.0/0.0  Hz   T2[--] : 0.0/0.0  Hz   T3[--] : 0.0/0.0  Hz   T4[--] : 0.0/0.0  Hz   T5[--] : 0.0/0.0  Hz   T6[--] : 0.0/0.0  Hz   T8[--] : 0.0/0.0  Hz   
    T1[+-] : 0.0/308442.5 Hz   T2[+-] : 0.0/273956.9 Hz   T3[+-] :2031.9/10159.6 Hz   T4[+-] :50.4/201.4 Hz   T5[+-] :749.6/749.6 Hz   T6[+-] :508.4/508.4 Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] : 0.0/0.0  Hz   T2[-+] : 0.0/0.0  Hz   T3[-+] : 0.0/0.0  Hz   T4[-+] : 0.0/0.0  Hz   T5[-+] : 0.0/0.0  Hz   T6[-+] : 0.0/0.0  Hz   T8[-+] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] :     30/512905213  T2[ 0] :     27/456074853  T3[ 0] :3391991/16959955  T4[ 0] :  84361/337444   T5[ 0] :1247765/1247765  T6[ 0] : 847726/847726   T8[ 0] :  17088/1708866  
    T1[++] :     14/251369586  T2[++] :     13/223808093  T3[++] :1669369/8346847  T4[++] :  41684/166738   T5[++] : 612104/612104   T6[++] : 416795/416795   T8[++] :   8407/840793   
    T1[--] :      0/0        T2[--] :      0/0        T3[--] :      0/0        T4[--] :      0/0        T5[--] :      0/0        T6[--] :      0/0        T8[--] :      0/0        
    T1[+-] :     15/253550899  T2[+-] :     13/225202493  T3[+-] :1670318/8351593  T4[+-] :  41394/165579   T5[+-] : 616223/616223   T6[+-] : 417883/417883   T8[+-] :   8417/841765   
    T1[-+] :      0/0        T2[-+] :      0/0        T3[-+] :      0/0        T4[-+] :      0/0        T5[-+] :      0/0        T6[-+] :      0/0        T8[-+] :      0/0        
    
    TRIGGER RATES (Unprescaled RHRS T1 and T2):   
    T1[ 0] :2009.2  T2[ 0] :58.1  
    T1[++] :2013.0  T2[++] :58.0  
    T1[--] : 0.0  T2[--] : 0.0  
    T1[+-] :2004.7  T2[+-] :58.2  
    T1[-+] : 0.0  T2[-+] : 0.0  
    
    TRIGGER TOTALS (Unprescaled RHRS T1 and T2): 
    T1[ 0] :3352917  T2[ 0] :  97041  
    T1[++] :1652859  T2[++] :  47645  
    T1[--] :      0  T2[--] :      0  
    T1[+-] :1647963  T2[+-] :  47859  
    T1[-+] :      0  T2[-+] :      0  
    
    AVERAGE CURRENT
    BCM x1 : 11.6456uA  BCM x3 : 11.6447uA  BCM x10: 10.9667uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :   -607.2 ppm     BCM u3 :     -724 ppm     BCM u10:   -721.6 ppm     
    BCM d1 :   -684.4 ppm     BCM d3 :   -815.8 ppm     BCM d10:   -719.9 ppm     
    
    Target -
    BCM u1 :    1E+39 ppm     BCM u3 :    1E+39 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :    1E+39 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:0.01955        BCM u3 [ 0]:0.01954        BCM u10[ 0]:0.01729        
    BCM u1 [++]:0.009619       BCM u3 [++]:0.009614       BCM u10[++]:0.008503       
    BCM u1 [--]:0              BCM u3 [--]:0              BCM u10[--]:0              
    BCM u1 [+-]:0.009631       BCM u3 [+-]:0.009628       BCM u10[+-]:0.008515       
    BCM u1 [-+]:0              BCM u3 [-+]:0              BCM u10[-+]:0              
    
    BCM d1 [ 0]:0.01932        BCM d3 [ 0]:0.01932        BCM d10[ 0]:0.01932        
    BCM d1 [++]:0.009502       BCM d3 [++]:0.009505       BCM d10[++]:0.009503       
    BCM d1 [--]:0              BCM d3 [--]:0              BCM d10[--]:0              
    BCM d1 [+-]:0.009515       BCM d3 [+-]:0.00952        BCM d10[+-]:0.009516       
    BCM d1 [-+]:0              BCM d3 [-+]:0              BCM d10[-+]:0              
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3008 at Sun May 31 13:55:10 EDT 2009
    
    Wien angle : 66.9203
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 2.27701
    Left Arm arm angle : 14.4997
    Right Arm D1 momentum : 2.17504
    Right Arm arm angle : 17.9982
    -----
    HALLA:p : 2425.5
    HALLA:dpp : -9.39999e-06
    Tiefenbach Hall A energy : 2425.5
    Left Arm Top VDC Current : -1.07422
    Left Arm Bottom VDC Current : -1.75781
    Left Arm Top VDC voltage : 3.98926
    Left Arm Bottom VDC voltage : 3.99756
    -----
    Right Arm Top VDC Current : -1.61133
    Right Arm Bottom VDC Current : 0.732422
    Right Arm Top VDC voltage : -0.012207
    Right Arm Bottom VDC voltage : 4.00732
    -----
    Left Arm Q1 momentum : 2.27723
    Left Arm Q1 power supply : 1713.23
    Left Arm Q1 gauss meter : -0.14444
    Left Arm Q2 gauss meter : 0.5155
    Left Arm Q2 power supply current : 980.382
    Left Arm Q2 momentum : 2.27678
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 777.782
    Left Arm D1 momentum : 2.27701
    Left Arm D1 NMR : 0.842564
    Left Arm Q3 gauss meter : -0.45732
    Left Arm Q3 power supply current : 906.412
    Left Arm Q3 momentum : 2.27674
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 518
    BigBite magnet current readback : 515.443
    BigBite Gaussmeter readback : -0.3204
    -----
    Average current of the two cavities : 11.5114
    Current on Unser monitor : 5.44444
    Current on Upstream bcm : 11.4536
    Current on Downstream bcm : 11.5693
    Upstream Cavity Coefficient : 44.3
    Downstream Cavity Coefficient : 43.49
    Current on IBC0L02 (source) : 11.1217
    Hall C Current : 0
    MBSY1c magnet current (amp) : 101.081
    MBSY1c Bdl : 606094
    Hall A momentum (Tiefenbach) (HALLA:p) : 2425.5
    Hall A momentum orbit correction (dpp) : -6.39357e-06
    Hall A setup momentum (MMSHLAE) : 2427.2
    Hall A energy (halla_MeV) : 2425.5
    Hall C energy (hallc_MeV) : 5971.72
    Delta(E)/E width (MV_AI_DXWID) : 0.609372
    IPM1C12.XPOS : 0.00474069
    IPM1H04A.XPOS : -0.47338
    IPM1H04A.YPOS : 2.14754
    IPM1H04B.XPOS : -0.504666
    IPM1H04B.YPOS : 1.98663
    -----
    HacL_HPE1313A:0_Ch58 : -0.195801
    HacL_HPE1313A:0_Ch55 : 23.2422
    HacL_HPE1313A:0_Ch54 : 0.0317383
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 14.4997
    Left VDC -DISC LVL Top : 3.89502
    Left VDC -DISC LVL Bottom : 3.96045
    Left VDC -DISC LVL Voltage1 : 4.97314
    Left VDC -DISC LVL Voltage2 : -5.05762
    -----
    Wien angle : 66.9203
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1537
    Wien field : 44.582
    Laser attenuation Hall A : 256
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : -10.5973
    Target OTR y-position : 5
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.58012
    SLI vert. size mm : 0
    SLI y position : 0.818779
    -----
    Polarized 3He Target
    RTD1 (upstream) : 80.8789
    RTD2 : 46.6895
    RTD3 : 40.3516
    RTD4 : 41.6406
    RTD5 (downstream) : 51.6992
    RTD6 (pump cell up) : 225
    RTD7 (pump cell down) : 250.957
    HacAi_hpchan7: Temp at Ref. Cell : -100
    HacAi_hpchan8: Temp at Ref. Cell : -19.6094
    HacAi_hpchan9: Temp at Ref. Cell : -20.3125
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -9.37
    Oven Air Flow : 229.8
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : 229.0
    HacOMEGA_SP1 : 230
    HacOMEGA_PROP1 : 30000
    HacOMEGA_RST1 : 600
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 9
    CLASER_TEMP : 14
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 8
    CLASER3_TEMP : 23
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 8
    CLASER4_TEMP : 16
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 9
    CLASER5_TEMP : 19.2
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 9
    CLASER6_TEMP : 14
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : 35.0011
    ntc1_temp : 26.0367
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 1024
    ----
    nld2_lasmdp : 34.002
    ntc2_temp : 20
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 1024
    ----
    nld3_lasmdp : 35.9971
    ntc3_temp : 25
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 1024
    ----
    DDM45_1disp1_read : 5.64
    DDM45_2disp1_read : 0.168184
    DDM45_3disp1_read : 4.099
    ----
    haPolHe3_Spin_State : 0
    haPolHe3_Flip_Sequence_ID : 36
    haPolHe3_Flip_Count : 0
    haPolHe3_EPR_ID : 0
    haPolHe3_EPR_POL : 0
    haPolHe3_Last_Flip_Start : 16:08:11 10/16/2008
    haPolHe3_Last_Flip_End : 20:00:00 12/31/1903
    haPolHe3_FLIP_NMR_PHASE : 0
    haPolHe3_FLIP_NMR_Mag : 0
    haPolHe3_FLIP_NMR_Pol : 61.5985
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : enabled
    HaGenTargPos : -9.37
    ----