Privacy and Security Notice

End_of_Run_3670


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 19:45:16 on June 16, 2009

    Entry number 281778

    keyword=End_of_Run_3670
    ****************************
     Run Number: 3670
     End of Run Comment:
    Run_type=Production,target_type=Multi Carbon Optics/BeO,targetpol_poldir=Transverse-in-plane,targetpol_pol=56.7,beam_e0=6.064,beam_raster=on,beam_halfwaveplate=in,leftarm_p=2.63,leftarm_theta=18.0,leftarm_sieve=out,bbarm_i=518,bbarm_theta=75,bbarm_sieve=out,bbarm_zoff=0,comment_text=tagger ON, beam HWP in
     
    
    PRESCALE FACTORS:ps1=65535   ps2=65535   ps3=1   ps4=5   ps5=65535   ps6=65535   ps7=65535   ps8=100   
    
    EVENTS   : [ 0]: 1679594      [++]: 827690       [--]: 829204       [+-]: 827012       [-+]: 828420       
    TIME     : [ 0]: 29.347 mins  [++]: 14.449 mins  [--]: 14.523 mins  [+-]: 14.458 mins  [-+]: 14.549 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -6.33252 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [ 0]:  15.36%      [++]:  15.21%      [--]:  15.18%      [+-]:  15.40%      [-+]:  15.24%      
    
    TRIGGER RATES:   PRES/REAL
    T1[ 0] : 0.0/20.0 Hz   T2[ 0] : 0.0/20.0 Hz   T3[ 0] :1094.6/1094.6 Hz   T4[ 0] :22.2/111.0 Hz   T5[ 0] : 0.0/2.5  Hz   T6[ 0] : 0.0/2.5  Hz   T8[ 0] :10.2/1024.0 Hz   
    T1[++] : 0.0/19.9 Hz   T2[++] : 0.0/19.9 Hz   T3[++] :1093.9/1093.9 Hz   T4[++] :22.0/109.8 Hz   T5[++] : 0.0/2.6  Hz   T6[++] : 0.0/2.6  Hz   T8[++] :10.2/1024.0 Hz   
    T1[--] : 0.0/20.0 Hz   T2[--] : 0.0/20.0 Hz   T3[--] :1089.4/1089.4 Hz   T4[--] :22.3/111.7 Hz   T5[--] : 0.0/2.5  Hz   T6[--] : 0.0/2.5  Hz   T8[--] :10.2/1024.0 Hz   
    T1[+-] : 0.0/20.1 Hz   T2[+-] : 0.0/20.1 Hz   T3[+-] :1094.3/1094.3 Hz   T4[+-] :22.4/112.2 Hz   T5[+-] : 0.0/2.5  Hz   T6[+-] : 0.0/2.5  Hz   T8[+-] :10.2/1024.0 Hz   
    T1[-+] : 0.0/19.8 Hz   T2[-+] : 0.0/19.8 Hz   T3[-+] :1087.7/1087.7 Hz   T4[-+] :21.8/109.2 Hz   T5[-+] : 0.0/2.5  Hz   T6[-+] : 0.0/2.5  Hz   T8[-+] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[ 0] :      0/35221    T2[ 0] :      0/35221    T3[ 0] :1927452/1927452  T4[ 0] :  39074/195372   T5[ 0] :      0/4438     T6[ 0] :      0/4438     T8[ 0] :  18031/1803105  
    T1[++] :      0/17267    T2[++] :      0/17266    T3[++] : 948375/948375   T4[++] :  19038/95191    T5[++] :      0/2214     T6[++] :      0/2214     T8[++] :   8877/887737   
    T1[--] :      0/17425    T2[--] :      0/17426    T3[--] : 949280/949280   T4[--] :  19464/97320    T5[--] :      0/2162     T6[--] :      0/2162     T8[--] :   8922/892281   
    T1[+-] :      0/17425    T2[+-] :      0/17425    T3[+-] : 949262/949262   T4[+-] :  19460/97304    T5[+-] :      0/2162     T6[+-] :      0/2162     T8[+-] :   8882/888297   
    T1[-+] :      0/17275    T2[-+] :      0/17275    T3[-+] : 949504/949504   T4[-+] :  19061/95305    T5[-+] :      0/2217     T6[-+] :      0/2217     T8[-+] :   8938/893869   
    
    TRIGGER RATES (Unprescaled RHRS T1 and T2):   
    T1[ 0] :1046.5  T2[ 0] :53.1  
    T1[++] :1043.0  T2[++] :52.0  
    T1[--] :1044.6  T2[--] :53.9  
    T1[+-] :1049.3  T2[+-] :54.1  
    T1[-+] :1037.1  T2[-+] :51.6  
    
    TRIGGER TOTALS (Unprescaled RHRS T1 and T2): 
    T1[ 0] :1842719  T2[ 0] :  93417  
    T1[++] : 904220  T2[++] :  45040  
    T1[--] : 910273  T2[--] :  46969  
    T1[+-] : 910269  T2[+-] :  46947  
    T1[-+] : 905306  T2[-+] :  45082  
    
    AVERAGE CURRENT
    BCM x1 : 33.1267uA  BCM x3 : 32.9480uA  BCM x10: 21.1116uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
     Target + 
    BCM u1 :   -378.7 ppm     BCM u3 :   -892.2 ppm     BCM u10:   -704.4 ppm     
    BCM d1 :   -718.4 ppm     BCM d3 :   -878.7 ppm     BCM d10:     1471 ppm     
    
    Target -
    BCM u1 :    -1073 ppm     BCM u3 :   -309.4 ppm     BCM u10:   -147.5 ppm     
    BCM d1 :   -472.4 ppm     BCM d3 :   -296.3 ppm     BCM d10:    -1509 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [ 0]:0.05893        BCM u3 [ 0]:0.05873        BCM u10[ 0]:0.03694        
    BCM u1 [++]:0.029          BCM u3 [++]:0.02889        BCM u10[++]:0.01817        
    BCM u1 [--]:0.02908        BCM u3 [--]:0.02894        BCM u10[--]:0.0182         
    BCM u1 [+-]:0.02903        BCM u3 [+-]:0.02894        BCM u10[+-]:0.0182         
    BCM u1 [-+]:0.02902        BCM u3 [-+]:0.02892        BCM u10[-+]:0.01819        
    
    BCM d1 [ 0]:0.05773        BCM d3 [ 0]:0.0573         BCM d10[ 0]:0.03741        
    BCM d1 [++]:0.02839        BCM d3 [++]:0.02819        BCM d10[++]:0.01841        
    BCM d1 [--]:0.02845        BCM d3 [--]:0.02823        BCM d10[--]:0.01844        
    BCM d1 [+-]:0.02843        BCM d3 [+-]:0.02823        BCM d10[+-]:0.01835        
    BCM d1 [-+]:0.02842        BCM d3 [-+]:0.02822        BCM d10[-+]:0.01839        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3670 at Tue Jun 16 19:45:09 EDT 2009
    
    Wien angle : 66.9203
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.62993
    Left Arm arm angle : 18.0003
    Right Arm D1 momentum : 2.62997
    Right Arm arm angle : 17.9999
    -----
    HALLA:p : 6063.87
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 6063.87
    Left Arm Top VDC Current : 0.0488281
    Left Arm Bottom VDC Current : 4.54102
    Left Arm Top VDC voltage : 3.99365
    Left Arm Bottom VDC voltage : 3.99805
    -----
    Right Arm Top VDC Current : -1.51367
    Right Arm Bottom VDC Current : -3.17383
    Right Arm Top VDC voltage : -0.0126953
    Right Arm Bottom VDC voltage : 4.00684
    -----
    Left Arm Q1 momentum : 2.63053
    Left Arm Q1 power supply : 1978.98
    Left Arm Q1 gauss meter : -0.167
    Left Arm Q2 gauss meter : 0.5954
    Left Arm Q2 power supply current : 1132.4
    Left Arm Q2 momentum : 2.62983
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 907.228
    Left Arm D1 momentum : 2.62993
    Left Arm D1 NMR : 0.97352
    Left Arm Q3 gauss meter : -0.52833
    Left Arm Q3 power supply current : 1047.06
    Left Arm Q3 momentum : 2.63003
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 518
    BigBite magnet current readback : 515.443
    BigBite Gaussmeter readback : -0.3202
    -----
    Average current of the two cavities : 0.0311027
    Current on Unser monitor : -8.3538
    Current on Upstream bcm : 0.0406897
    Current on Downstream bcm : 0.0215157
    Upstream Cavity Coefficient : 44.3
    Downstream Cavity Coefficient : 43.49
    Current on IBC0L02 (source) : 0.00721805
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.191
    MBSY1c Bdl : 1.51674e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6063.87
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6063.87
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.219282
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    HacL_HPE1313A:0_Ch58 : -0.160645
    HacL_HPE1313A:0_Ch55 : 23.2422
    HacL_HPE1313A:0_Ch54 : -0.0766602
    Left Arm Angle Vernier : 31.1
    Left Arm Scattering Angle : 18.0003
    Left VDC -DISC LVL Top : 3.896
    Left VDC -DISC LVL Bottom : 3.96338
    Left VDC -DISC LVL Voltage1 : 4.97412
    Left VDC -DISC LVL Voltage2 : -5.05615
    -----
    Wien angle : 66.9203
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1537
    Wien field : 44.582
    Laser attenuation Hall A : 70
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : -10.5973
    Target OTR y-position : 5
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.21366
    SLI vert. size mm : 0
    SLI y position : 1.57746
    -----
    Polarized 3He Target
    RTD1 (upstream) : 22.1094
    RTD2 : 21.6113
    RTD3 : 22.3145
    RTD4 : 22.8906
    RTD5 (downstream) : 22.4316
    RTD6 (pump cell up) : 0
    RTD7 (pump cell down) : 0
    HacAi_hpchan7: Temp at Ref. Cell : 0
    HacAi_hpchan8: Temp at Ref. Cell : 0
    HacAi_hpchan9: Temp at Ref. Cell : 0
    Reference Cell Gas Pressure (psi) : -277.5
    Reference Cell System Vacuum (Torr) : -282
    Cooling Jets Flow Rate : 0
    Target position : -5.39
    Oven Air Flow : 20.9
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : 020.9
    HacOMEGA_SP1 : 230
    HacOMEGA_PROP1 : 30000
    HacOMEGA_RST1 : 600
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 9
    CLASER_TEMP : 14
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 8
    CLASER3_TEMP : 23
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 8
    CLASER4_TEMP : 16
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 9
    CLASER5_TEMP : 19.2
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 9
    CLASER6_TEMP : 14
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : -9.9999
    ntc1_temp : -99.99
    nld1_lasouti : Disable
    ntc1_tecouti : Enable
    nld1_lascond : 512
    ----
    nld2_lasmdp : -9.9999
    ntc2_temp : -99.99
    nld2_lasouti : Disable
    ntc2_tecouti : Enable
    nld2_lascond : 512
    ----
    nld3_lasmdp : -9.9999
    ntc3_temp : -99.99
    nld3_lasouti : Disable
    ntc3_tecouti : Enable
    nld3_lascond : 512
    ----
    DDM45_1disp1_read : 0.203
    DDM45_2disp1_read : 0.168184
    DDM45_3disp1_read : -0.46
    ----
    haPolHe3_Spin_State : 0
    haPolHe3_Flip_Sequence_ID : 36
    haPolHe3_Flip_Count : 0
    haPolHe3_EPR_ID : 0
    haPolHe3_EPR_POL : 0
    haPolHe3_Last_Flip_Start : 16:08:11 10/16/2008
    haPolHe3_Last_Flip_End : 20:00:00 12/31/1903
    haPolHe3_FLIP_NMR_PHASE : 0
    haPolHe3_FLIP_NMR_Mag : 0
    haPolHe3_FLIP_NMR_Pol : 0
    HaGenTargSpin1 : disabled
    HaGenTargSpin2 : disabled
    HaGenTargPos : -5.39
    ----