Privacy and Security Notice

Start_Run_4045,Run_type=Test,target_type=No Target,targetpol_poldir=Transverse-in-plane,targetpol_pol=0,beam_e0=6.064,beam_raster=on,beam_halfwaveplate=in,leftarm_p=1.00,leftarm_theta=18.0,leftarm_sieve=out,bbarm_i=518,bbarm_theta=75,bbarm_sieve=out,bbarm_zoff=0,comment_text=cosmic checkout of HAPPEX trigger


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 14:18:57 on July 2, 2009

    Entry number 282020

    keyword=Start_Run_4045,Run_type=Test,target_type=No Target,targetpol_poldir=Transverse-in-plane,targetpol_pol=0,beam_e0=6.064,beam_raster=on,beam_halfwaveplate=in,leftarm_p=1.00,leftarm_theta=18.0,leftarm_sieve=out,bbarm_i=518,bbarm_theta=75,bbarm_sieve=out,bbarm_zoff=0,comment_text=cosmic checkout of HAPPEX trigger
    Run Timestamp:       Thu Jul  2 14:15:08 EDT 2009
    Beginning-of-run EPICS data for Run Number 4045 at Thu Jul 2 14:15:18 EDT 2009
    
    
    
    Run_type=Test
    target_type=No Target
    targetpol_poldir=Transverse-in-plane
    targetpol_pol=0
    beam_e0=6.064
    beam_raster=on
    beam_halfwaveplate=in
    leftarm_p=1.00
    leftarm_theta=18.0
    leftarm_sieve=out
    bbarm_i=518
    bbarm_theta=75
    bbarm_sieve=out
    bbarm_zoff=0
    comment_text=cosmic checkout of HAPPEX trigger
    
    
    ; HRS DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16777215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = R-HRS Singles (S1.and.S2) 
    ; T2 = R-HRS Efficiency
    ; T3 = L-HRS Singles (S1.and.S2) 
    ; T4 = L-HRS Efficiency 
    ; T8 = 1024 Hz pulser
    ; String should be one line, no spaces, ending in carriage return
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    
    ps1=1,ps2=9999,ps3=9999,ps4=9999,ps5=99999,ps6=65535,ps7=65535,ps8=65000
    
    
    Left Arm Q1 momentum : 0.000716599
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0003548
    Left Arm Q2 power supply current : -0.000273297
    Left Arm Q2 momentum : -1.50413e-06
    Left Arm Q2 gauss meter : 0.0009901
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -0.00293821
    Left Arm D1 momentum : 0.0028614
    Left Arm D1 NMR : 0.519923
    Left Arm Q3 power supply current : -0.000383677
    Left Arm Q3 momentum : -9.63726e-07
    Left Arm Q3 gauss meter : -0.00013203
    Left Arm Q3 power supply polarity : enabled
    Left Arm B Field Hall Probe (D-G) : -0.0010279
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    BigBite Gaussmeter readback : -0.002735
    -----
    Left Arm Top VDC Current : 1.36719
    Left Arm Bottom VDC Current : 1.41602
    Left Arm Top VDC voltage : 0.0175781
    Left Arm Bottom VDC voltage : 0.0180664
    -----
    Right Arm Top VDC Current : -1.51367
    Right Arm Bottom VDC Current : -1.36719
    Right Arm Top VDC voltage : -0.0131836
    Right Arm Bottom VDC voltage : -0.0117188
    -----
    Average current of the two cavities : 0.0252556
    Current on Unser monitor : -6.69547
    Current on Upstream bcm : 0.0348988
    Current on Downstream bcm : 0.0156123
    Upstream Cavity Coefficient : 44.3
    Downstream Cavity Coefficient : 43.49
    Current on IBC0L02 (source) : 0.00468834
    Hall C Current : 0
    Hall A momentum (Tiefenbach) (HALLA:p) : 6063.87
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 3667.5
    Hall A energy (halla_MeV) : 6063.87
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 2.63954
    MBSY1c magnet current (amp) : 0
    MBSY1c Bdl : 1.51674e+06
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Raster X width : EHAR_LIXWidth --- Invalid channel name
    Raster Y width : EHAR_LIYWidth --- Invalid channel name
    -----
    HacL_HPE1313A:0_Ch58 : -0.183105
    HacL_HPE1313A:0_Ch55 : 22.7539
    HacL_HPE1313A:0_Ch54 : -0.252441
    Left Arm Angle Floor Angle : 0
    Left Arm Angle Vernier : 0
    Left Arm Scattering Angle : -0.179
    -----
    Right Arm D1 momentum : 0.00482381
    Right Arm arm angle : 0.197
    -----
    Left VDC -DISC LVL Top : 3.89307
    Left VDC -DISC LVL Bottom : 3.95752
    Left VDC -DISC LVL Voltage1 : 4.97314
    Left VDC -DISC LVL Voltage2 : -5.05176
    -----
    IPM1C12.XPOS : 0
    IPM1C12.YPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : 66.9203
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 44.582
    Laser attenuation Hall A : 70
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    target OTR x-position : -10.5973
    target OTR y-position : 5
    target OTR x-width : 0
    target OTR y-width : -0
    target OTR data valid flag : No
    target OTR In/Out : OTR is Out
    -----
    RTD1 (upstream) : HacAi_hpchan0 --- Invalid channel name
    RTD2 : HacAi_hpchan1 --- Invalid channel name
    RTD3 : HacAi_hpchan2 --- Invalid channel name
    RTD4 : HacAi_hpchan3 --- Invalid channel name
    RTD5 (downstream) : HacAi_hpchan4 --- Invalid channel name
    RTD6 (pump cell up) : HacAi_hpchan5 --- Invalid channel name
    RTD7 (pump cell down) : HacAi_hpchan6 --- Invalid channel name
    HacAi_hpchan7: Temp at Ref. Cell : HacAi_hpchan7 --- Invalid channel name
    HacAi_hpchan8: Temp at Ref. Cell : HacAi_hpchan8 --- Invalid channel name
    HacAi_hpchan9: Temp at Ref. Cell : HacAi_hpchan9 --- Invalid channel name
    Reference Cell Gas Pressure (psi) : HacAi_hpchan60 --- Invalid channel name
    Reference Cell System Vacuum (Torr) : HacAi_hpchan61 --- Invalid channel name
    Cooling Jets Flow Rate : HacAi_hpchan62 --- Invalid channel name
    Target position : HaGenTargPos --- Invalid channel name
    Oven Air Flow : HacOMEGA_RTD --- Invalid channel name
    -----
    HaGenTargBrake : HaGenTargBrake --- Invalid channel name
    HaGenTargBrake : HaGenTargBrake --- Invalid channel name
    HacOMEGA_AL1 : HacOMEGA_AL1 --- Invalid channel name
    HacOMEGA_READ : HacOMEGA_READ --- Invalid channel name
    HacOMEGA_SP1 : HacOMEGA_SP1 --- Invalid channel name
    HacOMEGA_PROP1 : HacOMEGA_PROP1 --- Invalid channel name
    HacOMEGA_RST1 : HacOMEGA_RST1 --- Invalid channel name
    HacOMEGA_RATE : HacOMEGA_RATE1 --- Invalid channel name
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 9
    CLASER_TEMP : 14
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 8
    CLASER3_TEMP : 23
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 8
    CLASER4_TEMP : 16
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 9
    CLASER5_TEMP : 19.2
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 9
    CLASER6_TEMP : 14
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : -9.9999
    ntc1_temp : -99.99
    nld1_lasouti : Disable
    ntc1_tecouti : Enable
    nld1_lascond : 512
    ----
    nld2_lasmdp : -9.9999
    ntc2_temp : -99.99
    nld2_lasouti : Disable
    ntc2_tecouti : Enable
    nld2_lascond : 512
    ----
    nld3_lasmdp : -9.9999
    ntc3_temp : -99.99
    nld3_lasouti : Disable
    ntc3_tecouti : Enable
    nld3_lascond : 512
    ----
    DDM45_1disp1_read : DDM45_1disp1_read --- Invalid channel name
    DDM45_2disp1_read : DDM45_2disp1_read --- Invalid channel name
    DDM45_3disp1_read : DDM45_3disp1_read --- Invalid channel name
    ----
    haPolHe3_Spin_State : haPolHe3_Spin_State --- Invalid channel name
    haPolHe3_Flip_Sequence_ID : haPolHe3_Flip_Sequence_ID --- Invalid channel name
    haPolHe3_Flip_Count : haPolHe3_Flip_Count --- Invalid channel name
    haPolHe3_EPR_ID : haPolHe3_EPR_ID --- Invalid channel name
    haPolHe3_EPR_POL : haPolHe3_EPR_POL --- Invalid channel name
    haPolHe3_Last_Flip_Start : haPolHe3_Last_Flip_Start --- Invalid channel name
    haPolHe3_Last_Flip_End : haPolHe3_Last_Flip_End --- Invalid channel name
    haPolHe3_FLIP_NMR_PHASE : haPolHe3_FLIP_NMR_PHASE --- Invalid channel name
    haPolHe3_FLIP_NMR_Mag : haPolHe3_FLIP_NMR_Mag --- Invalid channel name
    haPolHe3_FLIP_NMR_Pol : haPolHe3_FLIP_NMR_Pol --- Invalid channel name
    HaGenTargSpin1 : HaGenTargSpin1 --- Invalid channel name
    HaGenTargSpin2 : HaGenTargSpin2 --- Invalid channel name
    HaGenTargPos : HaGenTargPos --- Invalid channel name
    ----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.46708
    SLI vert. size mm : 0
    SLI y position : 2.50141
    -----
    
    Left S2 HV Left PMTs
    S2 Slot0 ch0 Left : -1890.6
    S2 Slot0 ch1 Left : -1872.7
    S2 Slot0 ch2 Left : -2265.3
    S2 Slot0 ch3 Left : -2071.1
    S2 Slot0 ch4 Left : -2125.1
    S2 Slot0 ch5 Left : -1828.9
    S2 Slot0 ch6 Left : -2027.1
    S2 Slot0 ch7 Left : -1941.9
    S2 Slot0 ch8 Left : -1871.2
    S2 Slot0 ch9 Left : -2099.6
    S2 Slot0 ch10 Left : -2190.7
    S2 Slot0 ch11 Left : -2060.1
    S2 Slot13 ch0 Left : -2226.1
    S2 Slot13 ch1 Left : -2196.8
    S2 Slot13 ch2 Left : -1921.8
    S2 Slot13 ch3 Left : -1760.9
    -----
    Left S2 HV Right PMTs
    S2 Slot12 ch0 Right : -1777.1
    S2 Slot12 ch1 Right : -1791.4
    S2 Slot12 ch2 Right : -1968.6
    S2 Slot12 ch3 Right : -1889.5
    S2 Slot12 ch4 Right : -1984.6
    S2 Slot12 ch5 Right : -1931.3
    S2 Slot12 ch6 Right : -2001.3
    S2 Slot12 ch7 Right : -1939.2
    S2 Slot12 ch8 Right : -2025.6
    S2 Slot12 ch9 Right : -1988.7
    S2 Slot12 ch10 Right : -2040.6
    S2 Slot12 ch11 Right : -1790.9
    S2 Slot13 ch4 Right : -1801.3
    S2 Slot13 ch5 Right : -1925.6
    S2 Slot13 ch6 Right : -1906.1
    S2 Slot13 ch7 Right : -1901.4
    -----
    Left S1 HV
    S1 Slot1 ch0 : -1800.4
    S1 Slot1 ch1 : -1797.6
    S1 Slot1 ch2 : -1807.8
    S1 Slot1 ch3 : -1840
    S1 Slot1 ch4 : -1718.2
    S1 Slot1 ch5 : -1889.8
    S1 Slot1 ch6 : -1946.8
    S1 Slot1 ch7 : -1720.7
    S1 Slot1 ch8 : -1954.9
    S1 Slot1 ch9 : -1772.3
    S1 Slot1 ch10 : -1824.4
    S1 Slot1 ch11 : -1743.7
    -----
    Left Cerenkov HV
    GCER Slot2 ch0 : -1521.5
    GCER Slot2 ch1 : -1451.6
    GCER Slot2 ch2 : -1515.8
    GCER Slot2 ch3 : -1431
    GCER Slot2 ch4 : -1781.9
    GCER Slot2 ch5 : -2005.9
    GCER Slot2 ch6 : -30.2
    GCER Slot2 ch7 : -1724.8
    GCER Slot2 ch8 : -2006.1
    GCER Slot2 ch9 : -1549.6
    GCER Slot2 ch10 : -1663.1
    GCER Slot2 ch11 : -15.3
    -----
    Left Pion Rejector Layer 1 HV
    PRL1 Slot3 ch0 : -900.3
    PRL1 Slot3 ch1 : -815.1
    PRL1 Slot3 ch2 : -931.9
    PRL1 Slot3 ch3 : -985.8
    PRL1 Slot3 ch4 : -787.1
    PRL1 Slot3 ch5 : -886.9
    PRL1 Slot3 ch6 : -1095
    PRL1 Slot3 ch7 : -1012.6
    PRL1 Slot3 ch8 : -834.9
    PRL1 Slot3 ch9 : -816.1
    PRL1 Slot3 ch10 : -886.6
    PRL1 Slot3 ch11 : -809.5
    PRL1 Slot4 ch0 : -901.1
    PRL1 Slot4 ch1 : -931.4
    PRL1 Slot4 ch2 : -768.2
    PRL1 Slot4 ch3 : -941.2
    PRL1 Slot4 ch4 : -921.7
    PRL1 Slot4 ch5 : -824.3
    PRL1 Slot4 ch6 : -837.5
    PRL1 Slot4 ch7 : -829.5
    PRL1 Slot4 ch8 : -1190.3
    PRL1 Slot4 ch9 : -1039.2
    PRL1 Slot4 ch10 : -1079.5
    PRL1 Slot4 ch11 : -877.4
    PRL1 Slot5 ch0 : -1075.5
    PRL1 Slot5 ch1 : -902.4
    PRL1 Slot5 ch2 : -945.2
    PRL1 Slot5 ch3 : -764.9
    PRL1 Slot5 ch4 : -917.5
    PRL1 Slot5 ch5 : -823.3
    PRL1 Slot5 ch6 : -838.7
    PRL1 Slot5 ch7 : -891.8
    PRL1 Slot5 ch8 : -786.7
    PRL1 Slot5 ch9 : -841.4
    PRL1 Slot5 ch10 : -16.5
    PRL1 Slot5 ch11 : -25.6
    -----
    Left Pion Rejector Layer 2 HV
    PRL2 Slot9 ch0 : -900.6
    PRL2 Slot9 ch1 : -919.6
    PRL2 Slot9 ch2 : -794.8
    PRL2 Slot9 ch3 : -883.7
    PRL2 Slot9 ch4 : -812.4
    PRL2 Slot9 ch5 : -931.6
    PRL2 Slot9 ch6 : -852.2
    PRL2 Slot9 ch7 : -886.7
    PRL2 Slot9 ch8 : -827.5
    PRL2 Slot9 ch9 : -777.6
    PRL2 Slot9 ch10 : -834
    PRL2 Slot9 ch11 : -842.2
    PRL2 Slot10 ch0 : -754.2
    PRL2 Slot10 ch1 : -798.9
    PRL2 Slot10 ch2 : -861.1
    PRL2 Slot10 ch3 : -880.4
    PRL2 Slot10 ch4 : -968.4
    PRL2 Slot10 ch5 : -805.9
    PRL2 Slot10 ch6 : -796.1
    PRL2 Slot10 ch7 : -821.8
    PRL2 Slot10 ch8 : -773
    PRL2 Slot10 ch9 : -721.1
    PRL2 Slot10 ch10 : -901.8
    PRL2 Slot10 ch11 : -795.7
    PRL2 Slot11 ch0 : -989.2
    PRL2 Slot11 ch1 : -922.7
    PRL2 Slot11 ch2 : -863.6
    PRL2 Slot11 ch3 : -1079.1
    PRL2 Slot11 ch4 : -1053.3
    PRL2 Slot11 ch5 : -805.4
    PRL2 Slot11 ch6 : -858.9
    PRL2 Slot11 ch7 : -1007.6
    PRL2 Slot11 ch8 : -903.7
    PRL2 Slot11 ch9 : -863.5
    PRL2 Slot11 ch10 : -2.9
    PRL2 Slot11 ch11 : -11.7
    -----
    CODA config : config RightHrs
    HAPPEX run : 31699