Privacy and Security Notice
End_of_Run_4056
Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 17:13:53 on July 2, 2009
Entry number 282036
keyword=End_of_Run_4056
End-of-run EPICS data for Run Number 4056 at Thu Jul 2 17:13:21 EDT 2009
Wien angle : 66.9203
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.00285193
Left Arm arm angle : -0.179
Right Arm D1 momentum : 0.00483634
Right Arm arm angle : 0.197
-----
HALLA:p : 6063.87
HALLA:dpp : 0
Tiefenbach Hall A energy : 6063.87
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.46484
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.0180664
-----
Right Arm Top VDC Current : -1.5625
Right Arm Bottom VDC Current : -1.36719
Right Arm Top VDC voltage : -0.012207
Right Arm Bottom VDC voltage : -0.0102539
-----
Left Arm Q1 momentum : 0.000952858
Left Arm Q1 power supply : 0
Left Arm Q1 gauss meter : 0.0003743
Left Arm Q2 gauss meter : 0.0009299
Left Arm Q2 power supply current : -0.000254578
Left Arm Q2 momentum : -7.47716e-07
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00283455
Left Arm D1 momentum : 0.00285193
Left Arm D1 NMR : 0.519848
Left Arm Q3 gauss meter : -0.00014416
Left Arm Q3 power supply current : -0.000579278
Left Arm Q3 momentum : -1.01097e-06
Left Arm Q3 power supply polarity : enabled
-----
BigBite magnet current setpoint : 0
BigBite magnet current readback : 0
BigBite Gaussmeter readback : -0.002752
-----
Average current of the two cavities : 0.0275364
Current on Unser monitor : -7.08602
Current on Upstream bcm : 0.038404
Current on Downstream bcm : 0.0166689
Upstream Cavity Coefficient : 44.3
Downstream Cavity Coefficient : 43.49
Current on IBC0L02 (source) : 0.00493026
Hall C Current : 0
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 1.51674e+06
Hall A momentum (Tiefenbach) (HALLA:p) : 6063.87
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 3667.5
Hall A energy (halla_MeV) : 6063.87
Hall C energy (hallc_MeV) : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 2.7178
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
HacL_HPE1313A:0_Ch58 : -0.183105
HacL_HPE1313A:0_Ch55 : 22.8516
HacL_HPE1313A:0_Ch54 : -0.253418
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Left VDC -DISC LVL Top : 3.89355
Left VDC -DISC LVL Bottom : 3.9585
Left VDC -DISC LVL Voltage1 : 4.97314
Left VDC -DISC LVL Voltage2 : -5.05078
-----
Wien angle : 66.9203
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 3.18799
Wien field : 44.582
Laser attenuation Hall A : 70
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
-----
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern : Quartet
G0 Helicity Cycle Rate Read : 30 Hz
-----
Target OTR x-position : -10.5973
Target OTR y-position : 5
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 2.20621
SLI vert. size mm : 0
SLI y position : 0.578404
-----
Polarized 3He Target
RTD1 (upstream) :
RTD2 :
RTD3 :
RTD4 :
RTD5 (downstream) :
RTD6 (pump cell up) :
RTD7 (pump cell down) :
HacAi_hpchan7: Temp at Ref. Cell :
HacAi_hpchan8: Temp at Ref. Cell :
HacAi_hpchan9: Temp at Ref. Cell :
Reference Cell Gas Pressure (psi) :
Reference Cell System Vacuum (Torr) :
Cooling Jets Flow Rate :
Target position :
Oven Air Flow :
-----
HaGenTargBrake :
HaGenTargBrake :
HacOMEGA_AL1 :
HacOMEGA_READ :
HacOMEGA_SP1 :
HacOMEGA_PROP1 :
HacOMEGA_RST1 :
HacOMEGA_RATE :
-----
CLASER_STATE_MB : Disabled
CLASER_RDCUR : 9
CLASER_TEMP : 14
-----
CLASER2_STATE_MB : Disabled
CLASER2_RDCUR : 0
CLASER2_TEMP : 0
-----
CLASERAB_STATE_MB : Disabled
CLASERAB_GETCUR0 : 0
CLASERAB_GETCUR1 : 0
CLASERAB_GETTEMP0 : 0
CLASERAB_GETTEMP1 : 0
-----
CLASER3_STATE_MB : Disabled
CLASER3_RDCUR : 8
CLASER3_TEMP : 23
-----
CLASER4_STATE_MB : Disabled
CLASER4_RDCUR : 8
CLASER4_TEMP : 16
-----
CLASER5_STATE_MB : Disabled
CLASER5_RDCUR : 9
CLASER5_TEMP : 19.2
-----
CLASER6_STATE_MB : Disabled
CLASER6_RDCUR : 9
CLASER6_TEMP : 14
-----
CLASERAB2_STATE_M : Disabled
CLASERAB2_GETCUR0 : 0
CLASERAB2_GETCUR1 : 0
CLASERAB2_GETTEMP0 : 0
CLASERAB2_GETTEMP1 : 0
----
CLASERAB3_STATE_M : Disabled
CLASERAB3_GETCUR0 : 0
CLASERAB3_GETCUR1 : 0
CLASERAB3_GETTEMP0 : 0
CLASERAB3_GETTEMP1 : 0
----
nld1_lasmdp : -9.9999
ntc1_temp : -99.99
nld1_lasouti : Disable
ntc1_tecouti : Enable
nld1_lascond : 512
----
nld2_lasmdp : -9.9999
ntc2_temp : -99.99
nld2_lasouti : Disable
ntc2_tecouti : Enable
nld2_lascond : 512
----
nld3_lasmdp : -9.9999
ntc3_temp : -99.99
nld3_lasouti : Disable
ntc3_tecouti : Enable
nld3_lascond : 512
----
DDM45_1disp1_read : DDM45_1disp1_read --- Invalid channel name
DDM45_2disp1_read :
DDM45_3disp1_read :
----
haPolHe3_Spin_State :
haPolHe3_Flip_Sequence_ID :
haPolHe3_Flip_Count :
haPolHe3_EPR_ID :
haPolHe3_EPR_POL :
haPolHe3_Last_Flip_Start :
haPolHe3_Last_Flip_End :
haPolHe3_FLIP_NMR_PHASE :
haPolHe3_FLIP_NMR_Mag :
haPolHe3_FLIP_NMR_Pol :
HaGenTargSpin1 :
HaGenTargSpin2 :
HaGenTargPos :
----