    I have moved the fast clock module from the BigBite Weldment ROC 5 to the
    left HRS trigger supervisor in slot 12. I connected one of the NIM outputs
    to the module where the fast clock signal is fanned-out on the left HRS.
    This signal goes to the left HRS scalers and Fastbus crates.

    During E05-102 and E05-015, the fast clock signal for the right HRS also
    came from the BigBite weldment. One copy of the signal from the left HRS
    will now have to be sent to the right HRS. Until then, there is no fast
    clock signal on the right HRS.