Privacy and Security Notice

End_of_Run_24065


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 20:31:27 on July 28, 2009

    Entry number 282689

    keyword=End_of_Run_24065
    ****************************
     Run Number: 24065
     End of Run Comment:
    Run_type=Test,target_type=No Target,targetpol_poldir=Transverse-in-plane,targetpol_pol=0,beam_e0=6.064,beam_raster=on,beam_halfwaveplate=in,leftarm_p=1.00,leftarm_theta=18.0,leftarm_sieve=out,bbarm_i=518,bbarm_theta=75,bbarm_sieve=out,bbarm_zoff=0,comment_text=cavity signal adc checkout with battery
     100
    
    PRESCALE FACTORS:ps1=1   ps2=254   ps3=333   ps4=444   ps5=99999   ps6=65535   ps7=65535   ps8=20   
    
    EVENTS   : [0]: 0            
    TIME     : [0]: 0.017 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   0.00%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/0.0  Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/0.0  Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      0/0        T2[0] :      0/0        T3[0] :      0/0        T4[0] :      0/0        T5[0] :      0/0        T6[0] :      0/0        T7[0] :      0/0        T8[0] :      0/0        
    
    AVERAGE CURRENT
    BCM x1 : -0.1094uA  BCM x3 : -0.0324uA  BCM x10: -0.0169uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-1.528E-07     BCM u3 [0]:-4.801E-08     BCM u10[0]:-2.006E-08     
    
    BCM d1 [0]:-6.594E-08     BCM d3 [0]:-1.685E-08     BCM d10[0]:-1.367E-08     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 24065 at Tue Jul 28 20:31:00 EDT 2009
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00285138
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.00514703
    Right Arm arm angle : 0.197
    -----
    HALLA:p : 0
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 0
    Left Arm Top VDC Current : 1.36719
    Left Arm Bottom VDC Current : 1.46484
    Left Arm Top VDC voltage : 0.0170898
    Left Arm Bottom VDC voltage : 0.0180664
    -----
    Right Arm Top VDC Current : -1.5625
    Right Arm Bottom VDC Current : -1.31836
    Right Arm Top VDC voltage : -0.012207
    Right Arm Bottom VDC voltage : -0.0107422
    -----
    Left Arm Q1 momentum : 0.000746327
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0003526
    Left Arm Q2 gauss meter : 0.0006748
    Left Arm Q2 power supply current : -0.00040433
    Left Arm Q2 momentum : -9.38993e-07
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -0.00265225
    Left Arm D1 momentum : 0.00282187
    Left Arm D1 NMR : 0.519971
    Left Arm Q3 gauss meter : -6.171e-05
    Left Arm Q3 power supply current : -0.000361108
    Left Arm Q3 momentum : -4.06277e-07
    Left Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    BigBite Gaussmeter readback : -0.002671
    -----
    Average current of the two cavities : 0.0234155
    Current on Unser monitor : -6.77435
    Current on Upstream bcm : 0.0323896
    Current on Downstream bcm : 0.0144414
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 1.21498
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0
    MBSY1c Bdl : 1.51674e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 0
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 3667.5
    Hall A energy (halla_MeV) : 0
    Hall C energy (hallc_MeV) : 0
    Delta(E)/E width (MV_AI_DXWID) :
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    HacL_HPE1313A:0_Ch58 : -0.262695
    HacL_HPE1313A:0_Ch55 : 22.4609
    HacL_HPE1313A:0_Ch54 : -0.230957
    Left Arm Angle Vernier : 0
    Left Arm Scattering Angle : -0.179
    Left VDC -DISC LVL Top : 3.89697
    Left VDC -DISC LVL Bottom : 3.96875
    Left VDC -DISC LVL Voltage1 : 4.97607
    Left VDC -DISC LVL Voltage2 : -5.06494
    -----
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 0
    Wien field : 0
    Laser attenuation Hall A : 70
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : -10.5973
    Target OTR y-position : 5
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.63975
    SLI vert. size mm :
    SLI y position : 0.593427
    -----
    Polarized 3He Target
    RTD1 (upstream) :
    RTD2 : 0
    RTD3 :
    RTD4 : 42.8027
    RTD5 (downstream) :
    RTD6 (pump cell up) : 0
    RTD7 (pump cell down) :
    HacAi_hpchan7: Temp at Ref. Cell : 0
    HacAi_hpchan8: Temp at Ref. Cell :
    HacAi_hpchan9: Temp at Ref. Cell : 0
    Reference Cell Gas Pressure (psi) :
    Reference Cell System Vacuum (Torr) : -278.683
    Cooling Jets Flow Rate :
    Target position : 0
    Oven Air Flow : 0
    -----
    HaGenTargBrake :
    HaGenTargBrake : enabled
    HacOMEGA_AL1 :
    HacOMEGA_READ : string
    HacOMEGA_SP1 :
    HacOMEGA_PROP1 : 0
    HacOMEGA_RST1 :
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB :
    CLASER_RDCUR :
    CLASER_TEMP : 0
    -----
    CLASER2_STATE_MB :
    CLASER2_RDCUR :
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB :
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 :
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 :
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR :
    CLASER3_TEMP :
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR :
    CLASER4_TEMP :
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR :
    CLASER5_TEMP :
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 0
    CLASER6_TEMP :
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 :
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 :
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 :
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 :
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : -9.9999
    ntc1_temp :
    nld1_lasouti :
    ntc1_tecouti : Enable
    nld1_lascond :
    ----
    nld2_lasmdp : -9.9999
    ntc2_temp :
    nld2_lasouti : Enable
    ntc2_tecouti :
    nld2_lascond : 0
    ----
    nld3_lasmdp :
    ntc3_temp :
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond :
    ----
    DDM45_1disp1_read : 0
    DDM45_2disp1_read : 0
    DDM45_3disp1_read : 0
    ----
    haPolHe3_Spin_State :
    haPolHe3_Flip_Sequence_ID : 0
    haPolHe3_Flip_Count :
    haPolHe3_EPR_ID : 0
    haPolHe3_EPR_POL :
    haPolHe3_Last_Flip_Start : 0.000000000000000e+00
    haPolHe3_Last_Flip_End :
    haPolHe3_FLIP_NMR_PHASE : 0
    haPolHe3_FLIP_NMR_Mag :
    haPolHe3_FLIP_NMR_Pol : 0
    HaGenTargSpin1 :
    HaGenTargSpin2 : enabled
    HaGenTargPos :
    ----