Privacy and Security Notice

End_of_Run_24091


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 16:15:05 on July 30, 2009

    Entry number 282938

    keyword=End_of_Run_24091
    ****************************
     Run Number: 24091
     End of Run Comment:
    Run_type=Test,target_type=No Target,targetpol_poldir=Transverse-in-plane,targetpol_pol=0,beam_e0=6.064,beam_raster=on,beam_halfwaveplate=in,leftarm_p=1.00,leftarm_theta=18.0,leftarm_sieve=out,bbarm_i=518,bbarm_theta=75,bbarm_sieve=out,bbarm_zoff=0,comment_text=cavity signal adc checkout with battery
     
    
    PRESCALE FACTORS:can't read "psfacline": no such variable
        while executing
    "$w insert end "$psfacline..."
        (procedure "halla_scaler_process" line 296)
        invoked from within
    "halla_scaler_process .mid.tex scalerinfo "
    
    ****************************
    End-of-run EPICS data for Run Number 24091 at Thu Jul 30 16:14:36 EDT 2009
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00286251
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.00499414
    Right Arm arm angle : 0.197
    -----
    HALLA:p : HALLA:p --- Invalid channel name
    HALLA:dpp : HALLA:dpp --- Invalid channel name
    Tiefenbach Hall A energy : 0
    Left Arm Top VDC Current : 1.41602
    Left Arm Bottom VDC Current : 1.41602
    Left Arm Top VDC voltage : 0.0180664
    Left Arm Bottom VDC voltage : 0.0185547
    -----
    Right Arm Top VDC Current : -1.46484
    Right Arm Bottom VDC Current : -1.31836
    Right Arm Top VDC voltage : -0.012207
    Right Arm Bottom VDC voltage : -0.0107422
    -----
    Left Arm Q1 momentum : 0.000650885
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0003447
    Left Arm Q2 gauss meter : 0.0006775
    Left Arm Q2 power supply current : -0.000363148
    Left Arm Q2 momentum : -9.91159e-07
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -0.00261651
    Left Arm D1 momentum : 0.0028344
    Left Arm D1 NMR : 0.51989
    Left Arm Q3 gauss meter : -6.24e-05
    Left Arm Q3 power supply current : -0.000410008
    Left Arm Q3 momentum : -1.02986e-06
    Left Arm Q3 power supply polarity : enabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    BigBite Gaussmeter readback : -0.002628
    -----
    Average current of the two cavities : 0.0253854
    Current on Unser monitor : -6.19005
    Current on Upstream bcm : 0.0362831
    Current on Downstream bcm : 0.0144878
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.00535574
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0
    MBSY1c Bdl : 1.51674e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : HALLA:p --- Invalid channel name
    Hall A momentum orbit correction (dpp) : HALLA:dpp --- Invalid channel name
    Hall A setup momentum (MMSHLAE) : 3667.5
    Hall A energy (halla_MeV) : 0
    Hall C energy (hallc_MeV) : 0
    Delta(E)/E width (MV_AI_DXWID) : 1.32229
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    HacL_HPE1313A:0_Ch58 : -0.258789
    HacL_HPE1313A:0_Ch55 : 22.7051
    HacL_HPE1313A:0_Ch54 : -0.230469
    Left Arm Angle Vernier : 0
    Left Arm Scattering Angle : -0.179
    Left VDC -DISC LVL Top : 3.89453
    Left VDC -DISC LVL Bottom : 3.9624
    Left VDC -DISC LVL Voltage1 : 4.97266
    Left VDC -DISC LVL Voltage2 : -5.06543
    -----
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 0
    Wien field : 0
    Laser attenuation Hall A : 114
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : -1.62024
    Target OTR y-position : -0.459178
    Target OTR x-width : 1.03913
    Target OTR y-width : 0.670515
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.62484
    SLI vert. size mm : 0
    SLI y position : 1.33709
    -----
    Polarized 3He Target
    RTD1 (upstream) : 167.852
    RTD2 : 0
    RTD3 : 0
    RTD4 : 35.4883
    RTD5 (downstream) : 0
    RTD6 (pump cell up) : 0
    RTD7 (pump cell down) : 0
    HacAi_hpchan7: Temp at Ref. Cell : 0
    HacAi_hpchan8: Temp at Ref. Cell : 0
    HacAi_hpchan9: Temp at Ref. Cell : 0
    Reference Cell Gas Pressure (psi) : -275.967
    Reference Cell System Vacuum (Torr) : -279.183
    Cooling Jets Flow Rate : 0.390625
    Target position : 0
    Oven Air Flow : 0
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : string
    HacOMEGA_SP1 : 0
    HacOMEGA_PROP1 : 0
    HacOMEGA_RST1 : 0
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : Disabled
    CLASER_RDCUR : 0
    CLASER_TEMP : 0
    -----
    CLASER2_STATE_MB : Disabled
    CLASER2_RDCUR : 0
    CLASER2_TEMP : 0
    -----
    CLASERAB_STATE_MB : Disabled
    CLASERAB_GETCUR0 : 0
    CLASERAB_GETCUR1 : 0
    CLASERAB_GETTEMP0 : 0
    CLASERAB_GETTEMP1 : 0
    -----
    CLASER3_STATE_MB : Disabled
    CLASER3_RDCUR : 0
    CLASER3_TEMP : 0
    -----
    CLASER4_STATE_MB : Disabled
    CLASER4_RDCUR : 0
    CLASER4_TEMP : 0
    -----
    CLASER5_STATE_MB : Disabled
    CLASER5_RDCUR : 0
    CLASER5_TEMP : 0
    -----
    CLASER6_STATE_MB : Disabled
    CLASER6_RDCUR : 0
    CLASER6_TEMP : 0
    -----
    CLASERAB2_STATE_M : Disabled
    CLASERAB2_GETCUR0 : 0
    CLASERAB2_GETCUR1 : 0
    CLASERAB2_GETTEMP0 : 0
    CLASERAB2_GETTEMP1 : 0
    ----
    CLASERAB3_STATE_M : Disabled
    CLASERAB3_GETCUR0 : 0
    CLASERAB3_GETCUR1 : 0
    CLASERAB3_GETTEMP0 : 0
    CLASERAB3_GETTEMP1 : 0
    ----
    nld1_lasmdp : -9.9999
    ntc1_temp : -99.99
    nld1_lasouti : Enable
    ntc1_tecouti : Enable
    nld1_lascond : 0
    ----
    nld2_lasmdp : -9.9999
    ntc2_temp : -99.99
    nld2_lasouti : Enable
    ntc2_tecouti : Enable
    nld2_lascond : 0
    ----
    nld3_lasmdp : -9.9999
    ntc3_temp : -99.99
    nld3_lasouti : Enable
    ntc3_tecouti : Enable
    nld3_lascond : 0
    ----
    DDM45_1disp1_read : 0
    DDM45_2disp1_read : 0
    DDM45_3disp1_read : 0
    ----
    haPolHe3_Spin_State : 0
    haPolHe3_Flip_Sequence_ID : 0
    haPolHe3_Flip_Count : 0
    haPolHe3_EPR_ID : 0
    haPolHe3_EPR_POL : 0
    haPolHe3_Last_Flip_Start : 0.000000000000000e+00
    haPolHe3_Last_Flip_End : 0.000000000000000e+00
    haPolHe3_FLIP_NMR_PHASE : 0
    haPolHe3_FLIP_NMR_Mag : 0
    haPolHe3_FLIP_NMR_Pol : 0
    HaGenTargSpin1 : enabled
    HaGenTargSpin2 : enabled
    HaGenTargPos : 0
    ----