Privacy and Security Notice

Start_Parity_Run_44416__CODA_Config=TestCrate_Run_type=other,beam_energy=3.179,beam_polarization=186,beam_raster=on,comment_text=test,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=90Hz,target_type=Empty


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 00:57:50 on August 29, 2009

    Entry number 286689

    keyword=Start_Parity_Run_44416__CODA_Config=TestCrate_Run_type=other,beam_energy=3.179,beam_polarization=186,beam_raster=on,comment_text=test,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=90Hz,target_type=Empty
    Beginning-of-Parity-run EPICS data for Run Number 44416 at Sat Aug 29 00:57:39 EDT 2009
    CODA Configuration: TestCrate
    
    # Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 18410
    -----------------------------------------
    Wien angle                               : 44.3048
    Wien BDL                                 : 1012.9
    Wien field                               : 29.476
    Laser attenuation Hall A                 : 168
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.8
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5.2
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.554
    Gun2: PC (PITA) NEG                      : 6.238
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 1.99512
    Pockels Cell Voltage NEG                 : 1.83883
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr725mW
    Calculated power in cavity               : 845.823
    Photodiode on table                      : 389.831
    Laser X position on QPD 1                : 180.673
    Laser Y position on QPD 1                : 477.376
    Laser X position on QPD 2                : -36.6333
    Laser Y position on QPD 2                : -598.914
    QPD 1 sum                                : -1.58579
    QPD 2 sum                                : -1.06696
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -885[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -4040[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +48.3111
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.343649
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.137337
    Fast locking signal sent to laser        : 4.83611
    Calculated polarisation in cavity        : 98.2039
    Photodiode 1 after Wollaston prism       : 0.601017
    Photodiode 2 after Wollaston prism       : 66.3234
    Step size for RHWP scan                  : 11162
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 0
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot2 Ch9     : -1201.2
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : 13.9997
    Right Arm arm angle                      : 14.001
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 2363.51
    Left Arm Q1 momentum                     : 3.14158
    Left Arm Q1 gauss meter                  : -0.1995
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1352.66
    Left Arm Q2 momentum                     : 3.14134
    Left Arm Q2 gauss meter                  : 0.7106
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1103.34
    Left Arm D1 momentum                     : 3.14169
    Left Arm D1 NMR                          : 1.16341
    Left Arm Q3 power supply current         : 1250.59
    Left Arm Q3 momentum                     : 3.14125
    Left Arm Q3 gauss meter                  : -0.63072
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 2361.8
    Right Arm Q1 momentum                    : 3.14096
    Right Arm Q1 gauss meter                 : -0.05867
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1351.62
    Right Arm Q2 momentum                    : 3.14061
    Right Arm Q2 gauss meter                 : 0.7065
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1136.22
    Right Arm D1 momentum                    : 3.14167
    Right Arm D1 NMR                         : 1.16584
    Right Arm Q3 power supply current        : 1249.88
    Right Arm Q3 momentum                    : 3.14111
    Right Arm Q3 gauss meter                 : 0.5592
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : 1.36719
    Left Arm Bottom VDC Current              : 1.31836
    Right Arm Top VDC Current                : -1.66016
    Right Arm Bottom VDC Current             : -1.31836
    Left Arm Top VDC voltage                 : 0.0170898
    Left Arm Bottom VDC voltage              : 0.0175781
    Right Arm Top VDC voltage                : -0.012207
    Right Arm Bottom VDC voltage             : -0.00878906
    -----------------------------------------
    Beam Info
    -----------------------------------------
    Average current of the two cavities      : 9.65726
    Current on Unser monitor                 : 3.9364
    Current on Upstream bcm                  : 9.41338
    Current on Downstream bcm                : 9.90114
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 10.7742
    Tiefenbach Hall A energy                 : 3483.9
    Tiefenbach Hall C energy                 : 2344.63
    Delta(E)/E width (MV_AI_DXWID)           : 4.67188
    MBSY1c Hall A Beam energy                : 3489.72
    MBSY3c Hall C Beam energy                : 2349.74
    MBSY1c magnet current (amp)              : 145.346
    MBSY1c Bdl                               : 870863
    IPM1C12.XPOS                             : -0.00442779
    IPM1C12.YPOS                             : -0.113632
    IPM1H04A.XPOS                            : -0.215416
    IPM1H04A.YPOS                            : 1.02559
    IPM1H04B.XPOS                            : -2.23479
    IPM1H04B.YPOS                            : 2.28356
    Survey X offset bpmA                     : -0.63
    Survey Y offset bpmA                     : -0.9
    Survey X offset bpmB                     : 0.77
    Survey Y offset bpmB                     : -1
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.618799
    HacL_HPE1313A:0_Ch58                     : -0.196777
    HacL_HPE1313A:0_Ch55                     : 22.9004
    HacL_HPE1313A:0_Ch54                     : 0.0288086
    Left Arm Angle Floor Angle               : 14
    Left Arm Angle Vernier                   : 31
    Left Arm Scattering Angle                : 13.9997
    Right Arm Collimator                     : 0.615332
    HacR_HPE1313A:0_Ch58                     : -0.625
    HacR_HPE1313A:0_Ch55                     : 22.0703
    HacR_HPE1313A:0_Ch54                     : -0.961914
    Right Arm Angle Floor Angle              : 14
    Right Arm Angle Vernier                  : -34
    Right Arm Scattering Angle               : 14.001
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    Arc OTR  x-position                      : -2.12061
    Arc OTR  y-position                      : -1.41727
    Arc OTR  x-width                         : 2.94726
    Arc OTR  y-width                         : 2.21709
    Arc OTR  data valid flag                 : No
    Arc OTR  In/Out                          : OTR is Out
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------