User name apar
Log entry time 18:04:02 on August 30, 2009
Entry number 287116
keyword=End_of_Parity_Run_11793__CODA_Config=happex3
************************************************
Run Number: 11793
End of Run Comment:
Run_type=production,beam_energy=3.4839,beam_polarization=79,beam_raster=on,comment_text=production,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=60Hz,target_type=20cm LH2
************************************************
End-of-Parity-run EPICS data for Run Number 11793 at Sun Aug 30 18:03:53 EDT 2009
CODA Configuration: happex3
Compton Run Number : 18504
-----------------------------------------
Wien angle : 44.3048
Wien BDL : 1012.9
Wien field : 29.476
Laser attenuation Hall A : 124
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.84
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.1
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.554
Gun2: PC (PITA) NEG : 6.238
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00244
Pockels Cell Voltage NEG : 1.85104
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr725mW
Calculated power in cavity : 879.433
Photodiode on table : 390.08
Laser X position on QPD 1 : 175.885
Laser Y position on QPD 1 : 481.104
Laser X position on QPD 2 : -36.6333
Laser Y position on QPD 2 : -598.557
QPD 1 sum : -1.57969
QPD 2 sum : -1.06696
Position set point for adjustable
mirror 1 (either x or y) : -885[c]
Position set point for adjustable
mirror 2 (either x or y) : -4040[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +48.3133
Polarisation in cavity : LEFT
Reflection photodiode : 0.335103
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : 3.3492
Calculated polarisation in cavity : 98.1315
Photodiode 1 after Wollaston prism : 0.649371
Photodiode 2 after Wollaston prism : 68.8571
Step size for RHWP scan : 11162
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot2 Ch9 : -1400.3
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 13.9997
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.13
Left Arm Q1 momentum : 3.14108
Left Arm Q1 gauss meter : -0.19948
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.74
Left Arm Q2 momentum : 3.14152
Left Arm Q2 gauss meter : 0.7104
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1103.72
Left Arm D1 momentum : 3.14167
Left Arm D1 NMR : 1.16341
Left Arm Q3 power supply current : 1250.67
Left Arm Q3 momentum : 3.14144
Left Arm Q3 gauss meter : -0.63039
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.49
Right Arm Q1 momentum : 3.14181
Right Arm Q1 gauss meter : -0.05867
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1352.37
Right Arm Q2 momentum : 3.14236
Right Arm Q2 gauss meter : 0.7068
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1136.13
Right Arm D1 momentum : 3.14158
Right Arm D1 NMR : 1.1658
Right Arm Q3 power supply current : 1250.04
Right Arm Q3 momentum : 3.14153
Right Arm Q3 gauss meter : 0.5593
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.51367
Right Arm Top VDC Current : -1.61133
Right Arm Bottom VDC Current : -1.36719
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.0180664
Right Arm Top VDC voltage : -0.00830078
Right Arm Bottom VDC voltage : -0.00830078
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 59.1552
Current on Unser monitor : 50.3634
Current on Upstream bcm : 57.7799
Current on Downstream bcm : 60.7121
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 60.3696
Tiefenbach Hall A energy : 3483.93
Tiefenbach Hall C energy : 2344.59
Delta(E)/E width (MV_AI_DXWID) : 4.82842
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.74
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870863
IPM1C12.XPOS : 0.000698805
IPM1C12.YPOS : -0.129845
IPM1H04A.XPOS : -0.148841
IPM1H04A.YPOS : 0.938702
IPM1H04B.XPOS : -2.18942
IPM1H04B.YPOS : 2.20129
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.618848
HacL_HPE1313A:0_Ch58 : -0.197266
HacL_HPE1313A:0_Ch55 : 22.9492
HacL_HPE1313A:0_Ch54 : 0.0283203
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 13.9997
Right Arm Collimator : 0.615332
HacR_HPE1313A:0_Ch58 : -0.623047
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -0.959961
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
Arc OTR x-position : -2.12061
Arc OTR y-position : -1.41727
Arc OTR x-width : 2.94726
Arc OTR y-width : 2.21709
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------