     End of Run Comment:
    Run_type=Check out,target_type=No Target, Empty,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=3.48,beam_raster=on,beam_current=100,leftarm_p=3.14159,leftarm_theta=14.0,leftarm_sieve=out,rightarm_p=3.14159,rightarm_theta=14.0,rightarm_sieve=out,comment_text=check of cavity bpms at 5uA and more gain
     
    
    PRESCALE FACTORS:ps1=99999   ps2=99999   ps3=99999   ps4=99999   ps5=65535   ps6=65535   ps7=65535   ps8=4   
    
    EVENTS   : [0]: 14688        
    TIME     : [0]: 1.095 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  12.69%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/0.0  Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/0.0  Hz   T4[0] : 0.0/200.6 Hz   T5[0] : 0.0/146.3 Hz   T6[0] : 0.0/99.9 Hz   T7[0] : 0.0/200.6 Hz   T8[0] :256.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      0/0        T2[0] :      0/0        T3[0] :      0/0        T4[0] :      0/13180    T5[0] :      0/9614     T6[0] :      0/6563     T7[0] :      0/13181    T8[0] :  16822/67290    
    
    AVERAGE CURRENT
    BCM x1 : 2.5254 uA  BCM x3 : 2.5980 uA  BCM x10: 2.6205 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-1.004E-05     BCM u3 [0]:-1.348E-06     BCM u10[0]:-1.318E-06     
    
    BCM d1 [0]:0.0003419      BCM d3 [0]:0.0003428      BCM d10[0]:0.0003457      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4711 at Fri Oct 23 06:06:26 EDT 2009
    
    Wien angle : 17.1968
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 3.13707
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 3.14155
    Right Arm arm angle : 0.197
    -----
    HALLA:p : 3483.04
    HALLA:dpp : -0.000253573
    Tiefenbach Hall A energy : 3483.04
    Left Arm Top VDC Current : 1.51367
    Left Arm Bottom VDC Current : 1.46484
    Left Arm Top VDC voltage : 0.0175781
    Left Arm Bottom VDC voltage : 0.0185547
    -----
    Right Arm Top VDC Current : -1.75781
    Right Arm Bottom VDC Current : -1.41602
    Right Arm Top VDC voltage : -0.012207
    Right Arm Bottom VDC voltage : -0.00976562
    -----
    Left Arm Q1 momentum : 0.0146715
    Left Arm Q1 power supply : 10.6279
    Left Arm Q1 gauss meter : -0.0006287
    Left Arm Q2 gauss meter : 0.00441
    Left Arm Q2 power supply current : 6.81462
    Left Arm Q2 momentum : 0.0187288
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1101.71
    Left Arm D1 momentum : 3.13707
    Left Arm D1 NMR : 1.1617
    Left Arm Q3 gauss meter : -0.0058956
    Left Arm Q3 power supply current : 11.3462
    Left Arm Q3 momentum : 0.0333263
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    BigBite Gaussmeter readback : -0.003196
    -----
    Average current of the two cavities : 3.71821
    Current on Unser monitor : 7.25311
    Current on Upstream bcm : 2.11931
    Current on Downstream bcm : 5.3171
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 10.0697
    Hall C Current : 7.44
    MBSY1c magnet current (amp) : 145.346
    MBSY1c Bdl : 870864
    Hall A momentum (Tiefenbach) (HALLA:p) : 3483.04
    Hall A momentum orbit correction (dpp) : -0.000251902
    Hall A setup momentum (MMSHLAE) : 3484.12
    Hall A energy (halla_MeV) : 3483.04
    Hall C energy (hallc_MeV) : 2344.13
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.330943
    IPM1H04A.XPOS : -0.132777
    IPM1H04A.YPOS : 0.699288
    IPM1H04B.XPOS : 0.123426
    IPM1H04B.YPOS : -0.0539545
    -----
    HacL_HPE1313A:0_Ch58 : -0.211914
    HacL_HPE1313A:0_Ch55 : 22.9492
    HacL_HPE1313A:0_Ch54 : 0.0136719
    Left Arm Angle Vernier : 0
    Left Arm Scattering Angle : -0.179
    Left VDC -DISC LVL Top : 3.88672
    Left VDC -DISC LVL Bottom : 3.96582
    Left VDC -DISC LVL Voltage1 : 4.97705
    Left VDC -DISC LVL Voltage2 : -5.06982
    -----
    Right Arm Collimator : 0.009375
    HacR_HPE1313A:0_Ch58 : -0.625
    HacR_HPE1313A:0_Ch55 : 21.9727
    HacR_HPE1313A:0_Ch54 : -0.979492
    Right Arm Angle Floor Angle : 0
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 0.197
    -----
    Wien angle : 17.1968
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 395.55
    Wien field : 11.363
    Laser attenuation Hall A : 70
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 10
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : 8 cycles
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : -10.5973
    Target OTR y-position : 5
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0.446579
    SLI Energy spread *10^5 : 10.9097
    SLI x position : 2.69814
    SLI vert. size mm : 0.129248
    SLI y position : 2.0507
    -----
    Polarized 3He Target
    RTD1 (upstream) : 167.988
    RTD2 : 0
    RTD3 : 0
    RTD4 : 125.82
    RTD5 (downstream) : 0
    RTD6 (pump cell up) : 0
    RTD7 (pump cell down) : 0
    HacAi_hpchan7: Temp at Ref. Cell : 0
    HacAi_hpchan8: Temp at Ref. Cell : 0
    HacAi_hpchan9: Temp at Ref. Cell : 0
    Reference Cell Gas Pressure (psi) : -276.151
    Reference Cell System Vacuum (Torr) : -279.058
    Cooling Jets Flow Rate : 0.405273
    Target position : 0
    Oven Air Flow : 0
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : string
    HacOMEGA_SP1 : 0
    HacOMEGA_PROP1 : 0
    HacOMEGA_RST1 : 0
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : CLASER_STATE_MB --- Invalid channel name
    CLASER_RDCUR : CLASER_RDCUR --- Invalid channel name
    CLASER_TEMP : CLASER_TEMP --- Invalid channel name
    -----
    CLASER2_STATE_MB : CLASER2_STATE_MB --- Invalid channel name
    CLASER2_RDCUR : CLASER2_RDCUR --- Invalid channel name
    CLASER2_TEMP : CLASER2_TEMP --- Invalid channel name
    -----
    CLASERAB_STATE_MB : CLASERAB_STATE_MB --- Invalid channel name
    CLASERAB_GETCUR0 : CLASERAB_GETCUR0 --- Invalid channel name
    CLASERAB_GETCUR1 : CLASERAB_GETCUR1 --- Invalid channel name
    CLASERAB_GETTEMP0 : CLASERAB_GETTEMP0 --- Invalid channel name
    CLASERAB_GETTEMP1 :
    -----
    CLASER3_STATE_MB : CLASER3_STATE_MB --- Invalid channel name
    CLASER3_RDCUR : CLASER3_RDCUR --- Invalid channel name
    CLASER3_TEMP : CLASER3_TEMP --- Invalid channel name
    -----
    CLASER4_STATE_MB : CLASER4_STATE_MB --- Invalid channel name
    CLASER4_RDCUR : CLASER4_RDCUR --- Invalid channel name
    CLASER4_TEMP : CLASER4_TEMP --- Invalid channel name
    -----
    CLASER5_STATE_MB : CLASER5_STATE_MB --- Invalid channel name
    CLASER5_RDCUR : CLASER5_RDCUR --- Invalid channel name
    CLASER5_TEMP : CLASER5_TEMP --- Invalid channel name
    -----
    CLASER6_STATE_MB : CLASER6_STATE_MB --- Invalid channel name
    CLASER6_RDCUR : CLASER6_RDCUR --- Invalid channel name
    CLASER6_TEMP : CLASER6_TEMP --- Invalid channel name
    -----
    CLASERAB2_STATE_M : CLASERAB2_STATE_MB --- Invalid channel name
    CLASERAB2_GETCUR0 : CLASERAB2_GETCUR0 --- Invalid channel name
    CLASERAB2_GETCUR1 : CLASERAB2_GETCUR1 --- Invalid channel name
    CLASERAB2_GETTEMP0 :
    CLASERAB2_GETTEMP1 :
    ----
    CLASERAB3_STATE_M :
    CLASERAB3_GETCUR0 :
    CLASERAB3_GETCUR1 :
    CLASERAB3_GETTEMP0 :
    CLASERAB3_GETTEMP1 :
    ----
    nld1_lasmdp :
    ntc1_temp :
    nld1_lasouti :
    ntc1_tecouti :
    nld1_lascond :
    ----
    nld2_lasmdp :
    ntc2_temp :
    nld2_lasouti :
    ntc2_tecouti :
    nld2_lascond :
    ----
    nld3_lasmdp :
    ntc3_temp :
    nld3_lasouti :
    ntc3_tecouti :
    nld3_lascond :
    ----
    DDM45_1disp1_read : 0
    DDM45_2disp1_read : 0
    DDM45_3disp1_read : 0
    ----
    haPolHe3_Spin_State : 0
    haPolHe3_Flip_Sequence_ID : 0
    haPolHe3_Flip_Count : 0
    haPolHe3_EPR_ID : 0
    haPolHe3_EPR_POL : 0
    haPolHe3_Last_Flip_Start : 0.000000000000000e+00
    haPolHe3_Last_Flip_End : 0.000000000000000e+00
    haPolHe3_FLIP_NMR_PHASE : 0
    haPolHe3_FLIP_NMR_Mag : 0
    haPolHe3_FLIP_NMR_Pol : 0
    HaGenTargSpin1 : enabled
    HaGenTargSpin2 : enabled
    HaGenTargPos : 0
    ----