     Run Number: 25119
     End of Run Comment:
    Run_type=Calibration,target_type=Aluminium Dummy,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=3.48,beam_raster=on,beam_current=10,leftarm_p=3.14159,leftarm_theta=14.0,leftarm_sieve=out,rightarm_p=3.14159,rightarm_theta=14.0,rightarm_sieve=out,comment_text=spot++, dummy aluminium, 10  uA, S0 trigger
     
    current changed in the middle of the run
    
    PRESCALE FACTORS:ps1=99999   ps2=10   ps3=99999   ps4=99999   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 5966         
    TIME     : [0]: 1.060 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  11.31%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/728.4 Hz   T2[0] :105.6/1056.5 Hz   T3[0] : 0.0/2760.3 Hz   T4[0] : 0.0/2863.7 Hz   T5[0] : 0.0/0.0  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      0/46344    T2[0] :   6721/67217    T3[0] :      1/175623   T4[0] :      1/182204   T5[0] :      0/0        T6[0] :      0/0        T7[0] :      0/0        T8[0] :      0/65152    
    
    AVERAGE CURRENT
    BCM x1 : 0.9602 uA  BCM x3 : 0.5124 uA  BCM x10: 0.9680 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:6.043E-05      BCM u3 [0]:3.299E-06      BCM u10[0]:6.083E-05      
    
    BCM d1 [0]:6.175E-05      BCM d3 [0]:6.19E-05       BCM d10[0]:6.234E-05      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25119 at Mon Oct 26 19:01:06 EDT 2009
    
    Wien angle : 17.1968
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 3.14164
    Left Arm arm angle : 14.0003
    Right Arm D1 momentum : 0.00571771
    Right Arm arm angle : 0.197
    -----
    HALLA:p : 3482.7
    HALLA:dpp : -0.000349648
    Tiefenbach Hall A energy : 3482.7
    Left Arm Top VDC Current : 3.02734
    Left Arm Bottom VDC Current : -0.830078
    Left Arm Top VDC voltage : 3.99561
    Left Arm Bottom VDC voltage : 4.00195
    -----
    Right Arm Top VDC Current : -1.85547
    Right Arm Bottom VDC Current : -1.46484
    Right Arm Top VDC voltage : -0.00927734
    Right Arm Bottom VDC voltage : -0.00976562
    -----
    Left Arm Q1 momentum : 3.14236
    Left Arm Q1 power supply : 2364.1
    Left Arm Q1 gauss meter : -0.19933
    Left Arm Q2 gauss meter : 0.7099
    Left Arm Q2 power supply current : 1352.69
    Left Arm Q2 momentum : 3.1414
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1103.4
    Left Arm D1 momentum : 3.14164
    Left Arm D1 NMR : 1.1634
    Left Arm Q3 gauss meter : -0.63066
    Left Arm Q3 power supply current : 1250.51
    Left Arm Q3 momentum : 3.14105
    Left Arm Q3 power supply polarity : disabled
    -----
    BigBite magnet current setpoint : 0
    BigBite magnet current readback : 0
    BigBite Gaussmeter readback : -0.003123
    -----
    Average current of the two cavities : 0.972759
    Current on Unser monitor : 3.52212
    Current on Upstream bcm : 0.952968
    Current on Downstream bcm : 0.992551
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 9.21761
    Hall C Current : 8.25
    MBSY1c magnet current (amp) : 145.346
    MBSY1c Bdl : 870864
    Hall A momentum (Tiefenbach) (HALLA:p) : 3482.7
    Hall A momentum orbit correction (dpp) : -0.000349648
    Hall A setup momentum (MMSHLAE) : 3484.12
    Hall A energy (halla_MeV) : 3482.7
    Hall C energy (hallc_MeV) : 2344.13
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -0.539188
    IPM1H04A.YPOS : 1.49406
    IPM1H04B.XPOS : -1.3173
    IPM1H04B.YPOS : 2.0827
    -----
    HacL_HPE1313A:0_Ch58 : -0.213379
    HacL_HPE1313A:0_Ch55 : 22.7539
    HacL_HPE1313A:0_Ch54 : 0.012207
    Left Arm Angle Vernier : 31.1
    Left Arm Scattering Angle : 14.0003
    Left VDC -DISC LVL Top : 3.88721
    Left VDC -DISC LVL Bottom : 3.96875
    Left VDC -DISC LVL Voltage1 : 4.97754
    Left VDC -DISC LVL Voltage2 : -5.06543
    -----
    Right Arm Collimator : 0.0134277
    HacR_HPE1313A:0_Ch58 : -0.631348
    HacR_HPE1313A:0_Ch55 : 21.7285
    HacR_HPE1313A:0_Ch54 : -0.981445
    Right Arm Angle Floor Angle : 0
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 0.197
    -----
    Wien angle : 17.1968
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 395.55
    Wien field : 11.363
    Laser attenuation Hall A : 65
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : IN
    -----
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : 8 cycles
    G0 Helicity Pattern : Quartet
    G0 Helicity Cycle Rate Read : 30 Hz
    -----
    Target OTR x-position : -10.5973
    Target OTR y-position : 5
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.69814
    SLI vert. size mm : 0
    SLI y position : 1.12676
    -----
    Polarized 3He Target
    RTD1 (upstream) : 167.939
    RTD2 : 0
    RTD3 : 0
    RTD4 : 125.088
    RTD5 (downstream) : 0
    RTD6 (pump cell up) : 0
    RTD7 (pump cell down) : 0
    HacAi_hpchan7: Temp at Ref. Cell : 0
    HacAi_hpchan8: Temp at Ref. Cell : 0
    HacAi_hpchan9: Temp at Ref. Cell : 0
    Reference Cell Gas Pressure (psi) : -275.66
    Reference Cell System Vacuum (Torr) : -278.307
    Cooling Jets Flow Rate : 0.473633
    Target position : 0
    Oven Air Flow : 0
    -----
    HaGenTargBrake : enabled
    HaGenTargBrake : enabled
    HacOMEGA_AL1 : 0
    HacOMEGA_READ : string
    HacOMEGA_SP1 : 0
    HacOMEGA_PROP1 : 0
    HacOMEGA_RST1 : 0
    HacOMEGA_RATE : 0
    -----
    CLASER_STATE_MB : CLASER_STATE_MB --- Invalid channel name
    CLASER_RDCUR :
    CLASER_TEMP :
    -----
    CLASER2_STATE_MB :
    CLASER2_RDCUR :
    CLASER2_TEMP :
    -----
    CLASERAB_STATE_MB :
    CLASERAB_GETCUR0 :
    CLASERAB_GETCUR1 :
    CLASERAB_GETTEMP0 :
    CLASERAB_GETTEMP1 :
    -----
    CLASER3_STATE_MB :
    CLASER3_RDCUR :
    CLASER3_TEMP :
    -----
    CLASER4_STATE_MB :
    CLASER4_RDCUR :
    CLASER4_TEMP :
    -----
    CLASER5_STATE_MB :
    CLASER5_RDCUR :
    CLASER5_TEMP :
    -----
    CLASER6_STATE_MB :
    CLASER6_RDCUR :
    CLASER6_TEMP :
    -----
    CLASERAB2_STATE_M :
    CLASERAB2_GETCUR0 :
    CLASERAB2_GETCUR1 :
    CLASERAB2_GETTEMP0 :
    CLASERAB2_GETTEMP1 :
    ----
    CLASERAB3_STATE_M :
    CLASERAB3_GETCUR0 :
    CLASERAB3_GETCUR1 :
    CLASERAB3_GETTEMP0 :
    CLASERAB3_GETTEMP1 :
    ----
    nld1_lasmdp :
    ntc1_temp :
    nld1_lasouti :
    ntc1_tecouti :
    nld1_lascond :
    ----
    nld2_lasmdp :
    ntc2_temp :
    nld2_lasouti :
    ntc2_tecouti :
    nld2_lascond :
    ----
    nld3_lasmdp :
    ntc3_temp :
    nld3_lasouti :
    ntc3_tecouti :
    nld3_lascond :
    ----
    DDM45_1disp1_read :
    DDM45_2disp1_read : 0
    DDM45_3disp1_read :
    ----
    haPolHe3_Spin_State : 0
    haPolHe3_Flip_Sequence_ID :
    haPolHe3_Flip_Count : 0
    haPolHe3_EPR_ID :
    haPolHe3_EPR_POL : 0
    haPolHe3_Last_Flip_Start : 0.000000000000000e+00
    haPolHe3_Last_Flip_End : 0.000000000000000e+00
    haPolHe3_FLIP_NMR_PHASE :
    haPolHe3_FLIP_NMR_Mag : 0
    haPolHe3_FLIP_NMR_Pol :
    HaGenTargSpin1 :
    HaGenTargSpin2 : enabled