     Run Number: 4765
     End of Run Comment:
    Run_type=Pedestal,target_type=No Target, Empty,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=3.66,rightarm_theta=19.0,rightarm_sieve=out,comment_text=pedestal run
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=4   
    
    EVENTS   : [0]: 12520        
    TIME     : [0]: 3.271 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  75.09%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/16.1 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/166.6 Hz   T4[0] : 0.0/0.3  Hz   T5[0] : 0.0/5.8  Hz   T6[0] : 0.0/1.9  Hz   T7[0] : 0.0/2469.8 Hz   T8[0] :256.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      0/3166     T2[0] :      0/0        T3[0] :      0/32704    T4[0] :      0/54       T5[0] :      0/1136     T6[0] :      0/368      T7[0] :      7/484753   T8[0] :  50244/200979   
    
    AVERAGE CURRENT
    BCM x1 : 2.4286 uA  BCM x3 : 0.1369 uA  BCM x10: 2.5247 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-2.999E-05     BCM u3 [0]:5.703E-05      BCM u10[0]:-2.455E-06     
    
    BCM d1 [0]:0.0009833      BCM d3 [0]:-3.308E-06     BCM d10[0]:0.0009935      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4765 at Wed Nov 4 22:27:54 EST 2009
    
    Wien angle : 74.7279
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 3.66009
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.0546426
    Right Arm arm angle : 0.197
    -----
    HALLA:p : 6063.78
    HALLA:dpp : -1.49855e-05
    Tiefenbach Hall A energy : 6063.78
    Left Arm Top VDC Current : -1.9043
    Left Arm Bottom VDC Current : -1.26953
    Left Arm Top VDC voltage : 3.99463
    Left Arm Bottom VDC voltage : 3.99902
    -----
    Right Arm Top VDC Current : -12.5
    Right Arm Bottom VDC Current : 1.02539
    Right Arm Top VDC voltage : 4.00098
    Right Arm Bottom VDC voltage : 4.0127
    -----
    Left Arm Q1 momentum : 3.66043
    Left Arm Q1 power supply : 2753.86
    Left Arm Q1 gauss meter : -0.23216
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65965
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.55
    Left Arm D1 momentum : 3.66009
    Left Arm D1 NMR : 1.35577
    Left Arm Q3 gauss meter : -0.73456
    Left Arm Q3 power supply current : 1457.2
    Left Arm Q3 momentum : 3.66021
    Left Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 5.16558
    Current on Unser monitor : 23.0017
    Current on Upstream bcm : 5.03014
    Current on Downstream bcm : 5.30102
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 5.32936
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.191
    MBSY1c Bdl : 1.51674e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6063.79
    Hall A momentum orbit correction (dpp) : -1.47172e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6063.79
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 3.37542
    IPM1C12.XPOS : -0.000325114
    IPM1H04A.XPOS : 0.0880098
    IPM1H04A.YPOS : 1.61224
    IPM1H04B.XPOS : -0.494608
    IPM1H04B.YPOS : 2.52967
    -----
    HacL_HPE1313A:0_Ch58 : -0.242188
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : 0.0737305
    Left Arm Angle Vernier : 0
    Left Arm Scattering Angle : -0.179
    Left VDC -DISC LVL Top : 3.88477
    Left VDC -DISC LVL Bottom : 3.96387
    Left VDC -DISC LVL Voltage1 : 4.9751
    Left VDC -DISC LVL Voltage2 : -5.06641
    -----
    Right Arm Collimator : 0.0258789
    HacR_HPE1313A:0_Ch58 : -0.594727
    HacR_HPE1313A:0_Ch55 : 22.2168
    HacR_HPE1313A:0_Ch54 : -0.916016
    Right Arm Angle Floor Angle : 0
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 0.197
    -----
    Wien angle : 74.7279
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 69
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    Target : Clear
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 3.20255e+06
    Target type : 3.20255e+06
    temperature loop 1(1) : 22
    temperature loop 1(2) : 21.96
    temperature loop 1(3) : 22.3
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 294.6
    HPH H2 loop 1 : 609.192
    HPH H2 loop 3 : 0.00634721
    -----