Privacy and Security Notice

End_of_Run_4766


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 23:10:30 on November 4, 2009

    Entry number 297413

    keyword=End_of_Run_4766
    End-of-run EPICS data for Run Number 4766 at Wed Nov 4 23:10:26 EST 2009
    
    Wien angle : 74.7279
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 3.66009
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0.0476303
    Right Arm arm angle : 0.197
    -----
    HALLA:p : 6063.88
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 6063.88
    Left Arm Top VDC Current : -0.244141
    Left Arm Bottom VDC Current : 1.02539
    Left Arm Top VDC voltage : 3.98975
    Left Arm Bottom VDC voltage : 3.99902
    -----
    Right Arm Top VDC Current : -27.3438
    Right Arm Bottom VDC Current : 1.02539
    Right Arm Top VDC voltage : 3.99854
    Right Arm Bottom VDC voltage : 4.02734
    -----
    Left Arm Q1 momentum : 3.66043
    Left Arm Q1 power supply : 2753.86
    Left Arm Q1 gauss meter : -0.23218
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65965
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.55
    Left Arm D1 momentum : 3.66009
    Left Arm D1 NMR : 1.35578
    Left Arm Q3 gauss meter : -0.73458
    Left Arm Q3 power supply current : 1457.19
    Left Arm Q3 momentum : 3.66019
    Left Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 0.0226543
    Current on Unser monitor : 17.9505
    Current on Upstream bcm : 0.0328154
    Current on Downstream bcm : 0.0124932
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.126059
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.191
    MBSY1c Bdl : 1.51674e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6063.88
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6063.88
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 3.66891
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    HacL_HPE1313A:0_Ch58 : -0.242188
    HacL_HPE1313A:0_Ch55 : 22.9004
    HacL_HPE1313A:0_Ch54 : 0.0742188
    Left Arm Angle Vernier : 0
    Left Arm Scattering Angle : -0.179
    Left VDC -DISC LVL Top : 3.88525
    Left VDC -DISC LVL Bottom : 3.96387
    Left VDC -DISC LVL Voltage1 : 4.9751
    Left VDC -DISC LVL Voltage2 : -5.06836
    -----
    Right Arm Collimator : 0.0353027
    HacR_HPE1313A:0_Ch58 : -0.595703
    HacR_HPE1313A:0_Ch55 : 22.168
    HacR_HPE1313A:0_Ch54 : -0.916992
    Right Arm Angle Floor Angle : 0
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 0.197
    -----
    Wien angle : 74.7279
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 55
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    Target : Optics
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 1.26745e+07
    Target type : 1.26745e+07
    temperature loop 1(1) : 22.01
    temperature loop 1(2) : 21.97
    temperature loop 1(3) : 22.3
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 294.1
    HPH H2 loop 1 : 605.29
    HPH H2 loop 3 : 0.000504939
    -----