Privacy and Security Notice

Weird VDC TDC Spectra with Beam


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name V. Sulkosky

    Log entry time 00:19:19 on November 05, 2009

    Entry number 297430

    keyword=Weird VDC TDC Spectra with Beam

    There seems to be a trigger problem on the left HRS. Figure 1 shows
    the left VDC spectra for the TDCs for the four chambers during a
    cosmics run. Most of the events show up around 1700 or below, but
    there is a small secondary peak near 2200.

    On the other hand with beam, we see a completely different situation.
    The peak near 2200 becomes greatly enhanced with beam, but there is
    still a fairly large peak near 1700. This second peak structure is
    also seen in the scintillator and Cerenkov TDC spectra.

    I have never seen this type of behavior with a single trigger before.
    Both runs were taken with only T1, which is the coincidence between the
    S1 and S2m scintillator planes.

    A copy of this log entry has been emailed to: rom,rsubedi,reimer,xiaochao



    LHRS VDC TDC cosmics



    LHRS VDC TDC Beam