Privacy and Security Notice

End_of_Run_25182


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 00:34:40 on November 5, 2009

    Entry number 297434

    keyword=End_of_Run_25182
    ****************************
     Run Number: 25182
     End of Run Comment:
    Run_type=Check out,target_type=Optics,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=0,rightarm_theta=19.0,rightarm_sieve=out,comment_text=beam on carbon optics.1uA, Trtying a lower trigger rate
     
    
    PRESCALE FACTORS:ps1=100   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 51           
    TIME     : [0]: 0.610 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  35.49%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 2.0/206.9 Hz   T2[0] : 0.0/9.2  Hz   T3[0] : 0.0/40.0 Hz   T4[0] : 0.0/73.2 Hz   T5[0] : 0.0/177.3 Hz   T6[0] : 0.0/11.4 Hz   T7[0] : 0.1/4697.1 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :     75/7576     T2[0] :      0/338      T3[0] :      0/1464     T4[0] :      0/2682     T5[0] :      0/6494     T6[0] :      0/417      T7[0] :      2/172007   T8[0] :      0/37499    
    
    AVERAGE CURRENT
    BCM x1 : 1.1908 uA  BCM x3 : -0.0183uA  BCM x10: 1.2031 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:4.336E-05      BCM u3 [0]:-7.195E-07     BCM u10[0]:4.389E-05      
    
    BCM d1 [0]:4.385E-05      BCM d3 [0]:-6.172E-07     BCM d10[0]:4.423E-05      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25182 at Thu Nov 5 00:34:37 EST 2009
    
    Wien angle : 74.7279
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 3.66008
    Left Arm arm angle : 12.8988
    Right Arm D1 momentum : 0.0388712
    Right Arm arm angle : 20.001
    -----
    HALLA:p : 6063.79
    HALLA:dpp : -1.4618e-05
    Tiefenbach Hall A energy : 6063.79
    Left Arm Top VDC Current : 4.49219
    Left Arm Bottom VDC Current : 3.36914
    Left Arm Top VDC voltage : 3.99414
    Left Arm Bottom VDC voltage : 4.00049
    -----
    Right Arm Top VDC Current : 0.146484
    Right Arm Bottom VDC Current : -2.05078
    Right Arm Top VDC voltage : 4.00195
    Right Arm Bottom VDC voltage : 4.00732
    -----
    Left Arm Q1 momentum : 3.66036
    Left Arm Q1 power supply : 2753.8
    Left Arm Q1 gauss meter : -0.23216
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65965
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.55
    Left Arm D1 momentum : 3.66008
    Left Arm D1 NMR : 1.35577
    Left Arm Q3 gauss meter : -0.73457
    Left Arm Q3 power supply current : 1457.12
    Left Arm Q3 momentum : 3.66003
    Left Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 1.23682
    Current on Unser monitor : 18.7047
    Current on Upstream bcm : 1.20262
    Current on Downstream bcm : 1.27102
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 1.37412
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.191
    MBSY1c Bdl : 1.51674e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6063.8
    Hall A momentum orbit correction (dpp) : -1.29894e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6063.8
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 3.85495
    IPM1C12.XPOS : -0.0113386
    IPM1H04A.XPOS : -0.428946
    IPM1H04A.YPOS : 1.89752
    IPM1H04B.XPOS : -1.25264
    IPM1H04B.YPOS : 2.73323
    -----
    HacL_HPE1313A:0_Ch58 : -0.241211
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : 0.0737305
    Left Arm Angle Vernier : 13.5
    Left Arm Scattering Angle : 12.8988
    Left VDC -DISC LVL Top : 3.88721
    Left VDC -DISC LVL Bottom : 3.96533
    Left VDC -DISC LVL Voltage1 : 4.9751
    Left VDC -DISC LVL Voltage2 : -5.06787
    -----
    Right Arm Collimator : 0.0472168
    HacR_HPE1313A:0_Ch58 : -0.594727
    HacR_HPE1313A:0_Ch55 : 22.1191
    HacR_HPE1313A:0_Ch54 : -0.916504
    Right Arm Angle Floor Angle : 20
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : 20.001
    -----
    Wien angle : 74.7279
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 60
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    Target : Optics
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 1.26745e+07
    Target type : 1.26745e+07
    temperature loop 1(1) : 22.01
    temperature loop 1(2) : 21.97
    temperature loop 1(3) : 22.29
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 293.2
    HPH H2 loop 1 : 591.089
    HPH H2 loop 3 : 0.00230457
    -----