Privacy and Security Notice

Start_Run_25187,Run_type=Check out,target_type=Optics,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=0,rightarm_theta=19.0,rightarm_sieve=out,comment_text=beam on carbon optics.1uA, Trying Just disable T1


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 00:52:24 on November 5, 2009

    Entry number 297443

    keyword=Start_Run_25187,Run_type=Check out,target_type=Optics,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=0,rightarm_theta=19.0,rightarm_sieve=out,comment_text=beam on carbon optics.1uA, Trying Just disable T1
    Run Timestamp:       Thu Nov  5 00:52:04 EST 2009
    Beginning-of-run EPICS data for Run Number 25187 at Thu Nov 5 00:52:13 EST 2009
    
    
    
    Run_type=Check out
    target_type=Optics
    targetpol_poldir=Longitudinal
    targetpol_pol=87
    beam_e0=6.0
    beam_raster=off
    beam_current=0.0
    leftarm_p=3.66
    leftarm_theta=12.9
    leftarm_sieve=out
    rightarm_p=0
    rightarm_theta=19.0
    rightarm_sieve=out
    comment_text=beam on carbon optics.1uA, Trying Just disable T1
    
    
    ; L-HRS DAQ on adaql3/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16777215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = L-HRS HAPPEX Trigger
    ; T2 = L-HRS S0 trigger (of most importance)
    ; T3-T7 = Eventually PVDIS stuff
    ; T8 = 1024 Hz pulser
    ; String should be one line, no spaces, ending in carriage return
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    
    ps1=16777215,ps2=1,ps3=1,ps4=1,ps5=1,ps6=1,ps7=1,ps8=1
    
    
    
    Left Arm Q1 momentum : 3.66043
    Left Arm Q1 power supply : 2753.86
    Left Arm Q1 gauss meter : -0.23218
    Left Arm Q2 power supply current : 1575.84
    Left Arm Q2 momentum : 3.65965
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.56
    Left Arm D1 momentum : 3.66009
    Left Arm D1 NMR : 1.35577
    Left Arm Q3 power supply current : 1457.19
    Left Arm Q3 momentum : 3.66018
    Left Arm Q3 gauss meter : -0.73461
    Left Arm Q3 power supply polarity : disabled
    Left Arm B Field Hall Probe (D-G) : -1.3061
    -----
    Right Arm Q1 momentum : 0.00212619
    Right Arm Q1 power supply : 0.0534066
    Right Arm Q1 gauss meter : -5.18e-05
    Right Arm Q2 power supply current : 0.000114619
    Right Arm Q2 momentum : 0.00196058
    Right Arm Q2 gauss meter : 0.0004211
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 3.04817
    Right Arm D1 momentum : 0.0375221
    Right Arm D1 NMR : 0.33039
    Right Arm Q3 power supply current : 0.089152
    Right Arm Q3 momentum : 0.00250084
    Right Arm Q3 gauss meter : 0.0001446
    Right Arm Q3 power supply polarity : disabled
    Right Arm B Field Hall Probe (D-G) : -0.013764
    -----
    Left Arm Top VDC Current : 2.34375
    Left Arm Bottom VDC Current : 4.63867
    Left Arm Top VDC voltage : 3.99561
    Left Arm Bottom VDC voltage : 4
    -----
    Right Arm Top VDC Current : -10.5469
    Right Arm Bottom VDC Current : -0.488281
    Right Arm Top VDC voltage : 4.00146
    Right Arm Bottom VDC voltage : 4.021
    -----
    Average current of the two cavities : 1.24446
    Current on Unser monitor : 18.9187
    Current on Upstream bcm : 1.21305
    Current on Downstream bcm : 1.27586
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 1.38317
    Hall C Current : 0
    Hall A momentum (Tiefenbach) (HALLA:p) : 6063.77
    Hall A momentum orbit correction (dpp) : -1.7809e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6063.76
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 2.7618
    MBSY1c magnet current (amp) : 254.191
    MBSY1c Bdl : 1.51674e+06
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Raster X width : 0.2
    Raster Y width : 0.2
    -----
    HacL_HPE1313A:0_Ch58 : -0.241211
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : 0.0732422
    Left Arm Angle Floor Angle : 13
    Left Arm Angle Vernier : 13.5
    Left Arm Scattering Angle : 12.8988
    -----
    Right Arm D1 momentum : 0.0375112
    Right Arm arm angle : 20.001
    -----
    Left VDC -DISC LVL Top : 3.88525
    Left VDC -DISC LVL Bottom : 3.96387
    Left VDC -DISC LVL Voltage1 : 4.9751
    Left VDC -DISC LVL Voltage2 : -5.06885
    -----
    Right Arm Arm Collimator : 0.026123
    HacR_HPE1313A:0_Ch58 : -0.594727
    HacR_HPE1313A:0_Ch55 : 22.1191
    HacR_HPE1313A:0_Ch54 : -0.916992
    Right Arm Angle Floor Angle : 20
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : 20.001
    -----
    IPM1C12.XPOS : -0.00822702
    IPM1C12.YPOS : -0.01746
    IPM1H04A.XPOS : -0.409758
    IPM1H04A.YPOS : 1.90187
    IPM1H04B.XPOS : -1.30347
    IPM1H04B.YPOS : 2.7298
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : 74.7279
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 49.796
    Laser attenuation Hall A : 60
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Delay Set : 8 cycles
    Helicity Pattern Set : Quartet
    Helicity Clock Set : Free Clock
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    Helicity Clock Read : Free Clock
    Helicity Frequency : 29.5596
    -----
    Target : Optics
    fan frequency loop 1 : 59.5
    fan frequency loop 2 : 0
    fan frequency loop 3 : 0
    Encoder position : 1.26745e+07
    Target type : 1.26745e+07
    temperature loop 1(1) : 22
    temperature loop 1(2) : 21.96
    temperature loop 1(3) : 22.28
    Heat exchange loop 1 H2 : 24.5
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange loop 3 H2 : 293
    pressure loop He : 46.9098
    pressure loop H2 before : 25.3986
    pressure loop H2 return : 25.9525
    HPH He loop 1 : 603.992
    HPH He loop 2 : 0.00396968
    HPH H2 loop 3 : 0.00293052
    
    Left S2 HV Left PMTs
    S2 Slot0 ch0 Left : -1640.5
    S2 Slot0 ch1 Left : -1690.8
    S2 Slot0 ch2 Left : -2015.9
    S2 Slot0 ch3 Left : -1830.9
    S2 Slot0 ch4 Left : -1869.1
    S2 Slot0 ch5 Left : -1661.7
    S2 Slot0 ch6 Left : -1847.5
    S2 Slot0 ch7 Left : -1803.6
    S2 Slot0 ch8 Left : -1795.8
    S2 Slot0 ch9 Left : -1939.6
    S2 Slot0 ch10 Left : -1996.5
    S2 Slot0 ch11 Left : -1837.4
    S2 Slot13 ch0 Left : -1964.4
    S2 Slot13 ch1 Left : -1979.2
    S2 Slot13 ch2 Left : -1777.3
    S2 Slot13 ch3 Left : -1559
    -----
    Left S2 HV Right PMTs
    S2 Slot12 ch0 Right : -1464.5
    S2 Slot12 ch1 Right : -1607
    S2 Slot12 ch2 Right : -1765.9
    S2 Slot12 ch3 Right : -1680
    S2 Slot12 ch4 Right : -1762.6
    S2 Slot12 ch5 Right : -1732.5
    S2 Slot12 ch6 Right : -1765.1
    S2 Slot12 ch7 Right : -1486.6
    S2 Slot12 ch8 Right : -1840.5
    S2 Slot12 ch9 Right : -1715.1
    S2 Slot12 ch10 Right : -1836.8
    S2 Slot12 ch11 Right : -1550.1
    S2 Slot13 ch4 Right : -1552.3
    S2 Slot13 ch5 Right : -1635.9
    S2 Slot13 ch6 Right : -1650
    S2 Slot13 ch7 Right : -1621.3
    -----
    Left S1 HV
    S1 Slot1 ch0 : -1660.9
    S1 Slot1 ch1 : -1785.3
    S1 Slot1 ch2 : -1620.3
    S1 Slot1 ch3 : -1661.2
    S1 Slot1 ch4 : -1647.2
    S1 Slot1 ch5 : -1880.6
    S1 Slot1 ch6 : -1816
    S1 Slot1 ch7 : -1667.2
    S1 Slot1 ch8 : -1544.6
    S1 Slot1 ch9 : -1616.6
    S1 Slot1 ch10 : -1730.5
    S1 Slot1 ch11 : -1772.9
    -----
    Left Cerenkov HV
    GCER Slot2 ch0 : -1517.8
    GCER Slot2 ch1 : -1432
    GCER Slot2 ch2 : -1496
    GCER Slot2 ch3 : -1431
    GCER Slot2 ch4 : -1781.9
    GCER Slot2 ch5 : -1995.9
    GCER Slot2 ch6 : -25.6
    GCER Slot2 ch7 : -1724.8
    GCER Slot2 ch8 : -2005.3
    GCER Slot2 ch9 : -1499.8
    GCER Slot2 ch10 : -1525.1
    GCER Slot2 ch11 : -12.3
    -----
    Left Pion Rejector Layer 1 HV
    PRL1 Slot3 ch0 : -900.3
    PRL1 Slot3 ch1 : -815.1
    PRL1 Slot3 ch2 : -931.9
    PRL1 Slot3 ch3 : -986.6
    PRL1 Slot3 ch4 : -787.1
    PRL1 Slot3 ch5 : -886.9
    PRL1 Slot3 ch6 : -1095
    PRL1 Slot3 ch7 : -1012.6
    PRL1 Slot3 ch8 : -834.9
    PRL1 Slot3 ch9 : -816.1
    PRL1 Slot3 ch10 : -886.6
    PRL1 Slot3 ch11 : -809.5
    PRL1 Slot4 ch0 : -900.4
    PRL1 Slot4 ch1 : -932.2
    PRL1 Slot4 ch2 : -768.2
    PRL1 Slot4 ch3 : -941.2
    PRL1 Slot4 ch4 : -921.7
    PRL1 Slot4 ch5 : -824.3
    PRL1 Slot4 ch6 : -837.5
    PRL1 Slot4 ch7 : -829.5
    PRL1 Slot4 ch8 : -1190.3
    PRL1 Slot4 ch9 : -1039.2
    PRL1 Slot4 ch10 : -1079.5
    PRL1 Slot4 ch11 : -877.4
    PRL1 Slot5 ch0 : -1075.5
    PRL1 Slot5 ch1 : -902.4
    PRL1 Slot5 ch2 : -945.2
    PRL1 Slot5 ch3 : -764.9
    PRL1 Slot5 ch4 : -917.5
    PRL1 Slot5 ch5 : -823.3
    PRL1 Slot5 ch6 : -838.7
    PRL1 Slot5 ch7 : -891.8
    PRL1 Slot5 ch8 : -786.7
    PRL1 Slot5 ch9 : -840.6
    PRL1 Slot5 ch10 : -5.8
    PRL1 Slot5 ch11 : -14.9
    -----
    Left Pion Rejector Layer 2 HV
    PRL2 Slot9 ch0 : -899.8
    PRL2 Slot9 ch1 : -918.8
    PRL2 Slot9 ch2 : -794.8
    PRL2 Slot9 ch3 : -883.7
    PRL2 Slot9 ch4 : -811.6
    PRL2 Slot9 ch5 : -931.6
    PRL2 Slot9 ch6 : -852.2
    PRL2 Slot9 ch7 : -886.7
    PRL2 Slot9 ch8 : -828.3
    PRL2 Slot9 ch9 : -777.6
    PRL2 Slot9 ch10 : -834
    PRL2 Slot9 ch11 : -842.2
    PRL2 Slot10 ch0 : -754.2
    PRL2 Slot10 ch1 : -798.9
    PRL2 Slot10 ch2 : -861.1
    PRL2 Slot10 ch3 : -881.2
    PRL2 Slot10 ch4 : -968.4
    PRL2 Slot10 ch5 : -805.9
    PRL2 Slot10 ch6 : -796.1
    PRL2 Slot10 ch7 : -821.8
    PRL2 Slot10 ch8 : -773
    PRL2 Slot10 ch9 : -721.8
    PRL2 Slot10 ch10 : -901.8
    PRL2 Slot10 ch11 : -795.7
    PRL2 Slot11 ch0 : -989.2
    PRL2 Slot11 ch1 : -922.7
    PRL2 Slot11 ch2 : -864.4
    PRL2 Slot11 ch3 : -1079.1
    PRL2 Slot11 ch4 : -1053.3
    PRL2 Slot11 ch5 : -805.4
    PRL2 Slot11 ch6 : -858.9
    PRL2 Slot11 ch7 : -1007.6
    PRL2 Slot11 ch8 : -903.7
    PRL2 Slot11 ch9 : -863.5
    PRL2 Slot11 ch10 : -3.7
    PRL2 Slot11 ch11 : -11.7
    -----
    # Map  RHRS_VDC  Measured Voltage
       XXX 
    # Map  RHRS_VDC  Measured Current
       XXX 
    # Map  RHRS_PMTS  Measured Voltage
      1 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      2 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      3 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      4 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      5 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      6 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      7 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      8 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      9 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
     10 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
     11 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
     12 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
    # Map  RHRS_PMTS  Measured Current
      1 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      2 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      3 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      4 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      5 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      6 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      7 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      8 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      9 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
     10 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
     11 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
     12 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
    CODA config : config RightHrs LeftHrs
    HAPPEX run : 13731