Privacy and Security Notice

End_of_Run_25234


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 20:49:02 on November 5, 2009

    Entry number 297628

    keyword=End_of_Run_25234
    ****************************
     Run Number: 25234
     End of Run Comment:
    Run_type=Other,target_type=No Target, Empty,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=0,rightarm_theta=19.0,rightarm_sieve=out,comment_text=left arm HV alignment test run, 5uA
     
    
    PRESCALE FACTORS:can't read "psfacline": no such variable
        while executing
    "$w insert end "$psfacline..."
        (procedure "halla_scaler_process" line 296)
        invoked from within
    "halla_scaler_process .mid.tex scalerinfo "
    
    ****************************
    End-of-run EPICS data for Run Number 25234 at Thu Nov 5 20:48:59 EST 2009
    
    Left Arm Top VDC Current : 4.49219
    Left Arm Bottom VDC Current : 2.92969
    Left Arm Top VDC voltage : 3.99072
    Left Arm Bottom VDC voltage : 4.00146
    -----
    Right Arm Top VDC Current : 21.4844
    Right Arm Bottom VDC Current : -2.29492
    Right Arm Top VDC voltage : 4.00195
    Right Arm Bottom VDC voltage : 4.00244
    -----
    Left Arm Q1 momentum : 3.66029
    Left Arm Q1 power supply : 2753.75
    Left Arm Q1 gauss meter : -0.23214
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65965
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.51
    Left Arm D1 momentum : 3.66002
    Left Arm D1 NMR : 1.35575
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.7346
    Left Arm Q3 power supply current : 1457.17
    Left Arm Q3 momentum : 3.66014
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.63036
    Right Arm Q1 power supply : 1977.86
    Right Arm Q1 gauss meter : -0.04911
    Right Arm Q2 power supply current : -0.000550912
    Right Arm Q2 momentum : -1.2801e-06
    Right Arm Q2 gauss meter : 0.0004295
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 947.18
    Right Arm D1 momentum : 2.62477
    Right Arm D1 NMR : 0.974021
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.51
    Right Arm Q3 momentum : 2.63003
    Right Arm Q3 gauss meter : 0.4678
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 5.24617
    Current on Unser monitor : 22.013
    Current on Upstream bcm : 5.11134
    Current on Downstream bcm : 5.38101
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 5.2872
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.39
    Hall A momentum orbit correction (dpp) : -1.20157e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.39
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 3.36116
    IPM1C12.XPOS : 0.0106237
    IPM1H04A.XPOS : 0.168415
    IPM1H04A.YPOS : 1.32975
    IPM1H04B.XPOS : -0.102508
    IPM1H04B.YPOS : 1.20313
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 65
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Optics
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 1.26745e+07
    Target type : 1.26745e+07
    temperature loop 1(1) : 22.01
    temperature loop 1(2) : 21.96
    temperature loop 1(3) : 22.28
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 281.3
    HPH H2 loop 1 : 598.814
    HPH H2 loop 3 : 0.0155279