End-of-run EPICS data for Run Number 4788 at Thu Nov 5 21:06:43 EST 2009
Left Arm Top VDC Current : -2.00195
Left Arm Bottom VDC Current : 4.78516
Left Arm Top VDC voltage : 3.99609
Left Arm Bottom VDC voltage : 4.00098
-----
Right Arm Top VDC Current : 12.793
Right Arm Bottom VDC Current : -1.26953
Right Arm Top VDC voltage : 3.99756
Right Arm Bottom VDC voltage : 4.00293
-----
Left Arm Q1 momentum : 3.66029
Left Arm Q1 power supply : 2753.75
Left Arm Q1 gauss meter : -0.23217
Left Arm Q2 gauss meter : 0.8273
Left Arm Q2 power supply current : 1575.85
Left Arm Q2 momentum : 3.65966
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1325.5
Left Arm D1 momentum : 3.66002
Left Arm D1 NMR : 1.35575
Left Arm arm angle : 12.8988
Left Arm Q3 gauss meter : -0.73465
Left Arm Q3 power supply current : 1457.17
Left Arm Q3 momentum : 3.66014
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 2.63036
Right Arm Q1 power supply : 1977.86
Right Arm Q1 gauss meter : -0.04909
Right Arm Q2 power supply current : -0.000406713
Right Arm Q2 momentum : -6.44344e-07
Right Arm Q2 gauss meter : 0.000425
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 929.542
Right Arm D1 momentum : 2.62984
Right Arm D1 NMR : 0.975896
Right Arm arm angle : 20.001
Right Arm Q3 power supply current : 1046.51
Right Arm Q3 momentum : 2.63002
Right Arm Q3 gauss meter : 0.4678
Right Arm Q3 power supply polarity : disabled
-----
Average current of the two cavities : 5.22809
Current on Unser monitor : 21.6746
Current on Upstream bcm : 5.08445
Current on Downstream bcm : 5.37172
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 5.29816
Hall C Current : 0
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
Hall A momentum (Tiefenbach) (HALLA:p) : 6067.37
Hall A momentum orbit correction (dpp) : -1.50066e-05
Hall A setup momentum (MMSHLAE) : 6067.5
Hall A energy (halla_MeV) : 6067.37
Hall C energy (hallc_MeV) : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 3.12014
IPM1C12.XPOS : -0.0215977
IPM1H04A.XPOS : 0.16894
IPM1H04A.YPOS : 1.36503
IPM1H04B.XPOS : -0.0837999
IPM1H04B.YPOS : 1.25695
-----
Wien angle : 74.7279
Wien BDL : 1724.8
Wien field : 49.796
Laser attenuation Hall A : 65
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 1200
Beam Half-wave plate (off=out) : OUT
-----
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern : Quartet
-----
Target : Optics
fan frequency loop 1 : 59.5
fan frequency loop 3 : 0
Encoder position : 1.26745e+07
Target type : 1.26745e+07
temperature loop 1(1) : 21.99
temperature loop 1(2) : 21.94
temperature loop 1(3) : 22.27
temperature loop 3(1) : 99.99
temperature loop 3(2) : 99.99
temperature loop 3(3) : 29.99
Heat exchange LH2 : 24.4
Heat exchange LH2 : 281.1
HPH H2 loop 1 : 667.865
HPH H2 loop 3 : 0.000504939