Privacy and Security Notice

End_of_Run_25242


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 21:28:49 on November 5, 2009

    Entry number 297652

    keyword=End_of_Run_25242
    ****************************
     Run Number: 25242
     End of Run Comment:
    Run_type=Other,target_type=Optics,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=left arm HV alignment test run, 5uA
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 185210       
    TIME     : [0]: 2.658 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  24.78%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :1543.7/1543.7 Hz   T2[0] : 0.0/22.6 Hz   T3[0] : 0.0/581.3 Hz   T4[0] : 0.0/347.3 Hz   T5[0] : 0.0/585.7 Hz   T6[0] : 0.0/65.7 Hz   T7[0] : 0.1/6120.0 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 246225/246225   T2[0] :      0/3601     T3[0] :      0/92717    T4[0] :      0/55394    T5[0] :      1/93423    T6[0] :      0/10486    T7[0] :     14/976144   T8[0] :      2/163329   
    
    AVERAGE CURRENT
    BCM x1 : 4.6937 uA  BCM x3 : 0.0734 uA  BCM x10: 4.7403 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.000743       BCM u3 [0]:2.61E-05       BCM u10[0]:0.0007501      
    
    BCM d1 [0]:0.0007543      BCM d3 [0]:-2.688E-06     BCM d10[0]:0.0007621      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25242 at Thu Nov 5 21:28:46 EST 2009
    
    Left Arm Top VDC Current : 0.537109
    Left Arm Bottom VDC Current : 3.17383
    Left Arm Top VDC voltage : 3.99316
    Left Arm Bottom VDC voltage : 4.00049
    -----
    Right Arm Top VDC Current : -24.0234
    Right Arm Bottom VDC Current : -0.585938
    Right Arm Top VDC voltage : 4.00098
    Right Arm Bottom VDC voltage : 4.01953
    -----
    Left Arm Q1 momentum : 3.66029
    Left Arm Q1 power supply : 2753.75
    Left Arm Q1 gauss meter : -0.23215
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Q2 power supply current : 1575.84
    Left Arm Q2 momentum : 3.65963
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.5
    Left Arm D1 momentum : 3.66001
    Left Arm D1 NMR : 1.35575
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73458
    Left Arm Q3 power supply current : 1457.18
    Left Arm Q3 momentum : 3.66016
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.63029
    Right Arm Q1 power supply : 1977.86
    Right Arm Q1 gauss meter : -0.04909
    Right Arm Q2 power supply current : -0.0004252
    Right Arm Q2 momentum : -9.87994e-07
    Right Arm Q2 gauss meter : 0.0004335
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 931.776
    Right Arm D1 momentum : 2.63009
    Right Arm D1 NMR : 0.975994
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.46
    Right Arm Q3 momentum : 2.62989
    Right Arm Q3 gauss meter : 0.4678
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 5.40785
    Current on Unser monitor : 22.7063
    Current on Upstream bcm : 5.26536
    Current on Downstream bcm : 5.55033
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 5.46796
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.4
    Hall A momentum orbit correction (dpp) : -1.03725e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.4
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 3.43075
    IPM1C12.XPOS : -0.0166863
    IPM1H04A.XPOS : 0.179811
    IPM1H04A.YPOS : 1.35192
    IPM1H04B.XPOS : -0.078846
    IPM1H04B.YPOS : 1.22517
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 67
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Optics
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 1.26745e+07
    Target type : 1.26745e+07
    temperature loop 1(1) : 21.99
    temperature loop 1(2) : 21.94
    temperature loop 1(3) : 22.27
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.4
    Heat exchange LH2 : 281
    HPH H2 loop 1 : 638.191
    HPH H2 loop 3 : 0.00230457