     Run Number: 25243
     End of Run Comment:
    Run_type=Other,target_type=Optics,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=left arm HV alignment test run, 5uA
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 256263       
    TIME     : [0]: 3.273 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  23.78%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :1712.0/1712.0 Hz   T2[0] : 0.0/24.5 Hz   T3[0] : 0.0/648.4 Hz   T4[0] : 0.0/386.4 Hz   T5[0] : 0.0/638.2 Hz   T6[0] : 0.0/72.3 Hz   T7[0] : 0.1/6322.8 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 336230/336230   T2[0] :      0/4807     T3[0] :      0/127350   T4[0] :      0/75881    T5[0] :      1/125334   T6[0] :      0/14201    T7[0] :     18/1241801  T8[0] :      3/201114   
    
    AVERAGE CURRENT
    BCM x1 : 5.2453 uA  BCM x3 : 0.0849 uA  BCM x10: 5.2971 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.001023       BCM u3 [0]:3.666E-05      BCM u10[0]:0.001033       
    
    BCM d1 [0]:0.001037       BCM d3 [0]:-3.31E-06      BCM d10[0]:0.001048       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25243 at Thu Nov 5 21:33:06 EST 2009
    
    Left Arm Top VDC Current : 4.78516
    Left Arm Bottom VDC Current : -1.26953
    Left Arm Top VDC voltage : 3.99365
    Left Arm Bottom VDC voltage : 4.00098
    -----
    Right Arm Top VDC Current : -28.418
    Right Arm Bottom VDC Current : -2.05078
    Right Arm Top VDC voltage : 4
    Right Arm Bottom VDC voltage : 4.02344
    -----
    Left Arm Q1 momentum : 3.66036
    Left Arm Q1 power supply : 2753.75
    Left Arm Q1 gauss meter : -0.23216
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Q2 power supply current : 1575.83
    Left Arm Q2 momentum : 3.65963
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.5
    Left Arm D1 momentum : 3.66002
    Left Arm D1 NMR : 1.35575
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73458
    Left Arm Q3 power supply current : 1457.18
    Left Arm Q3 momentum : 3.66016
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.63029
    Right Arm Q1 power supply : 1977.86
    Right Arm Q1 gauss meter : -0.04912
    Right Arm Q2 power supply current : -0.00017008
    Right Arm Q2 momentum : -2.40555e-07
    Right Arm Q2 gauss meter : 0.0004346
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 931.745
    Right Arm D1 momentum : 2.63009
    Right Arm D1 NMR : 0.975994
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.51
    Right Arm Q3 momentum : 2.63001
    Right Arm Q3 gauss meter : 0.4679
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 5.35139
    Current on Unser monitor : 22.2669
    Current on Upstream bcm : 5.21175
    Current on Downstream bcm : 5.49103
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 5.40724
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.42
    Hall A momentum orbit correction (dpp) : -6.86027e-06
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.42
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 3.58349
    IPM1C12.XPOS : -0.0181157
    IPM1H04A.XPOS : 0.205131
    IPM1H04A.YPOS : 1.33397
    IPM1H04B.XPOS : -0.0595668
    IPM1H04B.YPOS : 1.20296
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 67
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Optics
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 1.26745e+07
    Target type : 1.26745e+07
    temperature loop 1(1) : 22
    temperature loop 1(2) : 21.96
    temperature loop 1(3) : 22.28
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 280.9
    HPH H2 loop 1 : 650.249
    HPH H2 loop 3 : 0.00230457