Privacy and Security Notice
End_of_Parity_Run_13744__CODA_Config=Pvdis
Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 21:33:28 on November 5, 2009
Entry number 297656
keyword=End_of_Parity_Run_13744__CODA_Config=Pvdis
************************************************
Run Number: 13744
End of Run Comment:
Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=test run,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=0,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 13744 at Thu Nov 5 21:33:17 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20860
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1724.8
Wien field : 49.796
Laser attenuation Hall A : 67
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.3
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.58
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.681
Gun2: PC (PITA) NEG : 6.019
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.99512
Pockels Cell Voltage NEG : 1.8315
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr741mW
Calculated power in cavity : 826.84
Photodiode on table : 384.845
Laser X position on QPD 1 : 117.356
Laser Y position on QPD 1 : 516.873
Laser X position on QPD 2 : 19.3433
Laser Y position on QPD 2 : -606.762
QPD 1 sum : -1.55405
QPD 2 sum : -1.18782
Position set point for adjustable
mirror 1 (either x or y) : -1520[c]
Position set point for adjustable
mirror 2 (either x or y) : -1420[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2270
Polarisation in cavity : LEFT
Reflection photodiode : 0.387597
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.159311
Fast locking signal sent to laser : -7.02619
Calculated polarisation in cavity : 98.1206
Photodiode 1 after Wollaston prism : 0.619839
Photodiode 2 after Wollaston prism : 65.3414
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.05
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 2753.8
Left Arm Q1 momentum : 3.66036
Left Arm Q1 gauss meter : -0.23216
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1575.83
Left Arm Q2 momentum : 3.65963
Left Arm Q2 gauss meter : 0.8272
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1325.5
Left Arm D1 momentum : 3.66002
Left Arm D1 NMR : 1.35575
Left Arm Q3 power supply current : 1457.18
Left Arm Q3 momentum : 3.66017
Left Arm Q3 gauss meter : -0.73459
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.86
Right Arm Q1 momentum : 2.63036
Right Arm Q1 gauss meter : -0.0491
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 0.000210751
Right Arm Q2 momentum : 0.00201361
Right Arm Q2 gauss meter : 0.0004308
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 931.715
Right Arm D1 momentum : 2.63007
Right Arm D1 NMR : 0.975989
Right Arm Q3 power supply current : 1046.51
Right Arm Q3 momentum : 2.63002
Right Arm Q3 gauss meter : 0.4679
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 5.28712
Current on Unser monitor : 22.6635
Current on Upstream bcm : 5.14206
Current on Downstream bcm : 5.43218
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 5.37373
Tiefenbach Hall A energy : 6067.38
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 3.61621
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0.0117174
IPM1C12.YPOS : 0.165292
IPM1H04A.XPOS : 0.185258
IPM1H04A.YPOS : 1.3362
IPM1H04B.XPOS : -0.0752914
IPM1H04B.YPOS : 1.20916
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.00947005
Survey Y offset bpm12 : 0.187189
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Optics
Encoder position : 12674482
fan frequency loop 1 : 60
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22
temperature loop 1-2 : 21.96
temperature loop 1-3 : 22.28
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 25.4627
pressure fill bottle H2 : 25.5207
pressure ballast H2 : 25.539
pressure exhaust H2 : 24.9195
cryogen input temp : 219.3
crogen return flow : 0.50804
JT valve setting : -0.683594
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 0
No HAPPEX feedback runlog entry for Run #13744
Was feedback on?