Privacy and Security Notice

End_of_Run_25246


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 22:19:14 on November 5, 2009

    Entry number 297668

    keyword=End_of_Run_25246
    ****************************
     Run Number: 25246
     End of Run Comment:
    Run_type=Other,target_type=Optics,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=left arm HV alignment test run
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 705819       
    TIME     : [0]: 11.878 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  31.58%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :1447.5/1447.5 Hz   T2[0] : 0.0/27.8 Hz   T3[0] : 0.0/301.1 Hz   T4[0] : 0.0/299.8 Hz   T5[0] : 0.0/443.4 Hz   T6[0] : 0.0/38.6 Hz   T7[0] : 0.1/6181.5 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :1031586/1031586  T2[0] :      0/19837    T3[0] :      0/214602   T4[0] :      0/213642   T5[0] :      4/316032   T6[0] :      0/27535    T7[0] :     67/4405400  T8[0] :     11/729781   
    
    AVERAGE CURRENT
    BCM x1 : 9.0965 uA  BCM x3 : 0.0668 uA  BCM x10: 9.1870 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.00647        BCM u3 [0]:0.0001072      BCM u10[0]:0.006532       
    
    BCM d1 [0]:0.006496       BCM d3 [0]:-1.201E-05     BCM d10[0]:0.006563       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25246 at Thu Nov 5 22:19:10 EST 2009
    
    Left Arm Top VDC Current : 1.51367
    Left Arm Bottom VDC Current : 1.46484
    Left Arm Top VDC voltage : 0.0180664
    Left Arm Bottom VDC voltage : 0.0185547
    -----
    Right Arm Top VDC Current : -1.61133
    Right Arm Bottom VDC Current : -1.41602
    Right Arm Top VDC voltage : -0.00927734
    Right Arm Bottom VDC voltage : -0.0102539
    -----
    Left Arm Q1 momentum : 0.00124231
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0002296
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Q2 power supply current : 1575.84
    Left Arm Q2 momentum : 3.65964
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.51
    Left Arm D1 momentum : 3.65999
    Left Arm D1 NMR : 1.35574
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.7346
    Left Arm Q3 power supply current : 1457.2
    Left Arm Q3 momentum : 3.66022
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 0.00291092
    Right Arm Q1 power supply : 0.106813
    Right Arm Q1 gauss meter : -7.49e-05
    Right Arm Q2 power supply current : -0.000225541
    Right Arm Q2 momentum : -5.24066e-07
    Right Arm Q2 gauss meter : 0.0004335
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 132.028
    Right Arm D1 momentum : 0.395825
    Right Arm D1 NMR : 0.49438
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : -0.00473763
    Right Arm Q3 momentum : -1.13242e-05
    Right Arm Q3 gauss meter : 5.2e-05
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 20.424
    Current on Unser monitor : 37.2156
    Current on Upstream bcm : 19.9078
    Current on Downstream bcm : 20.9403
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 20.4042
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.39
    Hall A momentum orbit correction (dpp) : -1.20849e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.39
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 3.69098
    IPM1C12.XPOS : -0.00418916
    IPM1H04A.XPOS : -0.139728
    IPM1H04A.YPOS : 2.21133
    IPM1H04B.XPOS : -0.453066
    IPM1H04B.YPOS : 2.51351
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 81
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : L1 20cm
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 3.30777e+07
    Target type : 3.30777e+07
    temperature loop 1(1) : 22.01
    temperature loop 1(2) : 21.97
    temperature loop 1(3) : 22.35
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.6
    Heat exchange LH2 : 280.7
    HPH H2 loop 1 : 991.684
    HPH H2 loop 3 : 0.00540827