     Run Number: 4790
     End of Run Comment:
    Run_type=Other,target_type=Optics,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=RHRS Diple is down
     
    
    PRESCALE FACTORS:ps1=100   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 500877       
    TIME     : [0]: 24.621 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  49.71%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :673.8/67378.4 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/3353.3 Hz   T4[0] : 0.0/1.5  Hz   T5[0] : 0.0/1286.9 Hz   T6[0] : 0.0/242.7 Hz   T7[0] : 0.4/25166.3 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 995340/99534043  T2[0] :      0/0        T3[0] :      0/4953605  T4[0] :      0/2279     T5[0] :     29/1901119  T6[0] :      5/358572   T7[0] :    567/37176735  T8[0] :     23/1512694  
    
    AVERAGE CURRENT
    BCM x1 : 18.1768uA  BCM x3 : 1.6926 uA  BCM x10: 14.6468uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-0.0002257     BCM u3 [0]:0.005026       BCM u10[0]:0.0001949      
    
    BCM d1 [0]:0.05393        BCM d3 [0]:-2.49E-05      BCM d10[0]:0.04308        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4790 at Thu Nov 5 22:46:42 EST 2009
    
    Left Arm Top VDC Current : 1.46484
    Left Arm Bottom VDC Current : 1.51367
    Left Arm Top VDC voltage : 0.0175781
    Left Arm Bottom VDC voltage : 0.019043
    -----
    Right Arm Top VDC Current : -1.85547
    Right Arm Bottom VDC Current : -1.46484
    Right Arm Top VDC voltage : -0.00927734
    Right Arm Bottom VDC voltage : -0.0107422
    -----
    Left Arm Q1 momentum : 0.000826123
    Left Arm Q1 power supply : 0.0534066
    Left Arm Q1 gauss meter : 0.0002562
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.82
    Left Arm Q2 momentum : 3.6596
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : -1.34424
    Left Arm D1 momentum : 0.000446232
    Left Arm D1 NMR : 1.46204
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73459
    Left Arm Q3 power supply current : 1457.18
    Left Arm Q3 momentum : 3.66017
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 0.00225345
    Right Arm Q1 power supply : 0.106813
    Right Arm Q1 gauss meter : -6.25e-05
    Right Arm Q2 power supply current : -0.000258818
    Right Arm Q2 momentum : -7.13074e-07
    Right Arm Q2 gauss meter : 0.0004339
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 46.9113
    Right Arm D1 momentum : 0.224675
    Right Arm D1 NMR : 0.453274
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : -0.00435653
    Right Arm Q3 momentum : -1.09486e-05
    Right Arm Q3 gauss meter : 4.9e-05
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 39.4635
    Current on Unser monitor : 97.6387
    Current on Upstream bcm : 78.903
    Current on Downstream bcm : 0.0239924
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.0179691
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.46
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.46
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 2.92806
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 60
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : L1 20cm
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 3.30777e+07
    Target type : 3.30777e+07
    temperature loop 1(1) : 21.93
    temperature loop 1(2) : 21.89
    temperature loop 1(3) : 22.22
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 280.5
    HPH H2 loop 1 : 507.045
    HPH H2 loop 3 : 0.000817917