Privacy and Security Notice
End_of_Run_4792
Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 23:24:21 on November 5, 2009
Entry number 297686
keyword=End_of_Run_4792
End-of-run EPICS data for Run Number 4792 at Thu Nov 5 23:24:17 EST 2009
Left Arm Top VDC Current : 1.46484
Left Arm Bottom VDC Current : 1.51367
Left Arm Top VDC voltage : 0.0175781
Left Arm Bottom VDC voltage : 0.019043
-----
Right Arm Top VDC Current : -1.80664
Right Arm Bottom VDC Current : -1.41602
Right Arm Top VDC voltage : -0.00976562
Right Arm Bottom VDC voltage : -0.0107422
-----
Left Arm Q1 momentum : 2.60505
Left Arm Q1 power supply : 1959.86
Left Arm Q1 gauss meter : -0.16528
Left Arm Q2 gauss meter : 0.8273
Left Arm Q2 power supply current : 1575.83
Left Arm Q2 momentum : 3.65963
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 793.275
Left Arm D1 momentum : 0
Left Arm D1 NMR : 1.58282
Left Arm arm angle : 12.8988
Left Arm Q3 gauss meter : -0.73462
Left Arm Q3 power supply current : 1457.23
Left Arm Q3 momentum : 3.66028
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 0.467419
Right Arm Q1 power supply : 353.925
Right Arm Q1 gauss meter : -0.008892
Right Arm Q2 power supply current : -0.000244028
Right Arm Q2 momentum : -7.73213e-08
Right Arm Q2 gauss meter : 0.0004311
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 27.0904
Right Arm D1 momentum : 0.145995
Right Arm D1 NMR : 1.16221
Right Arm arm angle : 20.001
Right Arm Q3 power supply current : -0.00348597
Right Arm Q3 momentum : -8.30063e-06
Right Arm Q3 gauss meter : 5.02e-05
Right Arm Q3 power supply polarity : disabled
-----
Average current of the two cavities : 31.888
Current on Unser monitor : 48.1365
Current on Upstream bcm : 31.0371
Current on Downstream bcm : 32.7389
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 31.072
Hall C Current : 0
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
Hall A momentum (Tiefenbach) (HALLA:p) : 6067.99
Hall A momentum orbit correction (dpp) : 8.67747e-05
Hall A setup momentum (MMSHLAE) : 6067.5
Hall A energy (halla_MeV) : 6067.99
Hall C energy (hallc_MeV) : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 3.2153
IPM1C12.XPOS : -0.207742
IPM1H04A.XPOS : -0.160184
IPM1H04A.YPOS : 2.4223
IPM1H04B.XPOS : -0.441411
IPM1H04B.YPOS : 2.76865
-----
Wien angle : 74.7279
Wien BDL : 1724.8
Wien field : 49.796
Laser attenuation Hall A : 88
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 1200
Beam Half-wave plate (off=out) : OUT
-----
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern : Quartet
-----
Target : L1 20cm
fan frequency loop 1 : 60
fan frequency loop 3 : 0
Encoder position : 3.30777e+07
Target type : 3.30777e+07
temperature loop 1(1) : 22.03
temperature loop 1(2) : 21.99
temperature loop 1(3) : 22.37
temperature loop 3(1) : 99.99
temperature loop 3(2) : 99.99
temperature loop 3(3) : 29.99
Heat exchange LH2 : 24.6
Heat exchange LH2 : 280.1
HPH H2 loop 1 : 991.684
HPH H2 loop 3 : 0.00634721