Privacy and Security Notice

End_of_Run_4792


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 23:42:04 on November 5, 2009

    Entry number 297690

    keyword=End_of_Run_4792
    ****************************
     Run Number: 4792
     End of Run Comment:
    Run_type=Other,target_type=Optics,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=RHRS Diple is down
     
    
    PRESCALE FACTORS:ps1=100   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 499191       
    TIME     : [0]: 32.526 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  49.32%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :504.0/50401.3 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/2797.1 Hz   T4[0] : 0.0/1.9  Hz   T5[0] : 0.0/1131.5 Hz   T6[0] : 0.0/373.5 Hz   T7[0] : 0.7/45253.8 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 983620/98362069  T2[0] :      0/0        T3[0] :      0/5458790  T4[0] :      0/3643     T5[0] :     33/2208120  T6[0] :     11/728932   T7[0] :   1347/88316346  T8[0] :     30/1998417  
    
    AVERAGE CURRENT
    BCM x1 : 33.0746uA  BCM x3 : 3.0695 uA  BCM x10: 20.1005uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-0.0002982     BCM u3 [0]:0.01201        BCM u10[0]:0.0002082      
    
    BCM d1 [0]:0.1294         BCM d3 [0]:-3.289E-05     BCM d10[0]:0.07825        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4792 at Thu Nov 5 23:42:00 EST 2009
    
    Left Arm Top VDC Current : 1.46484
    Left Arm Bottom VDC Current : 1.51367
    Left Arm Top VDC voltage : 0.0180664
    Left Arm Bottom VDC voltage : 0.019043
    -----
    Right Arm Top VDC Current : -1.70898
    Right Arm Bottom VDC Current : -1.41602
    Right Arm Top VDC voltage : -0.00976562
    Right Arm Bottom VDC voltage : -0.0112305
    -----
    Left Arm Q1 momentum : 3.66029
    Left Arm Q1 power supply : 2753.75
    Left Arm Q1 gauss meter : -0.23213
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.83
    Left Arm Q2 momentum : 3.65963
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.53
    Left Arm D1 momentum : 3.66014
    Left Arm D1 NMR : 1.35579
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73461
    Left Arm Q3 power supply current : 1457.22
    Left Arm Q3 momentum : 3.66027
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.36025
    Right Arm Q1 power supply : 1774.75
    Right Arm Q1 gauss meter : -0.04407
    Right Arm Q2 power supply current : 0.000136804
    Right Arm Q2 momentum : 0.00196411
    Right Arm Q2 gauss meter : 0.0004233
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 21.1787
    Right Arm D1 momentum : 0.122121
    Right Arm D1 NMR : 0.714578
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : -0.00359433
    Right Arm Q3 momentum : -9.03304e-06
    Right Arm Q3 gauss meter : 4.81e-05
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 0.0313461
    Current on Unser monitor : 15.7824
    Current on Upstream bcm : 0.03823
    Current on Downstream bcm : 0.0244622
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.0103592
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.46
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.46
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 3.40216
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 60
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : L1 20cm
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 3.30777e+07
    Target type : 3.30777e+07
    temperature loop 1(1) : 21.95
    temperature loop 1(2) : 21.91
    temperature loop 1(3) : 22.21
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.4
    Heat exchange LH2 : 280
    HPH H2 loop 1 : 1275.47
    HPH H2 loop 3 : 0.000817917