Privacy and Security Notice

End_of_Run_25249


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 04:14:28 on November 6, 2009

    Entry number 297711

    keyword=End_of_Run_25249
    ****************************
     Run Number: 25249
     End of Run Comment:
    Run_type=Qsq,target_type=Liquid H2, 20cm,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=Qsq on L-HRS
     
    
    PRESCALE FACTORS:ps1=60   ps2=20   ps3=100   ps4=100   ps5=100   ps6=20   ps7=500   ps8=65535   
    
    EVENTS   : [0]: 74360        
    TIME     : [0]: 5.915 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   3.31%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :132.7/7960.0 Hz   T2[0] : 4.1/81.4 Hz   T3[0] :15.8/1578.7 Hz   T4[0] :16.0/1604.8 Hz   T5[0] :20.1/2008.7 Hz   T6[0] : 4.6/91.6 Hz   T7[0] :24.1/12062.8 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  47084/2825071  T2[0] :   1444/28897    T3[0] :   5603/560306   T4[0] :   5695/569556   T5[0] :   7129/712909   T6[0] :   1625/32507    T7[0] :   8562/4281205  T8[0] :      5/363428   
    
    AVERAGE CURRENT
    BCM x1 : 2.0127 uA  BCM x3 : 0.5132 uA  BCM x10: 2.0327 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0007119      BCM u3 [0]:0.0003702      BCM u10[0]:0.0007191      
    
    BCM d1 [0]:0.0007167      BCM d3 [0]:-5.982E-06     BCM d10[0]:0.0007237      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25249 at Fri Nov 6 04:14:24 EST 2009
    
    Left Arm Top VDC Current : 3.27148
    Left Arm Bottom VDC Current : -1.95312
    Left Arm Top VDC voltage : 3.99414
    Left Arm Bottom VDC voltage : 4.00049
    -----
    Right Arm Top VDC Current : -1.70898
    Right Arm Bottom VDC Current : -1.41602
    Right Arm Top VDC voltage : -0.00976562
    Right Arm Bottom VDC voltage : -0.0102539
    -----
    Left Arm Q1 momentum : 3.66036
    Left Arm Q1 power supply : 2753.86
    Left Arm Q1 gauss meter : -0.23215
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Q2 power supply current : 1575.83
    Left Arm Q2 momentum : 3.65961
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.27
    Left Arm D1 momentum : 3.66011
    Left Arm D1 NMR : 1.35578
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73457
    Left Arm Q3 power supply current : 1457.23
    Left Arm Q3 momentum : 3.66028
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 0.00196182
    Right Arm Q1 power supply : 0.106813
    Right Arm Q1 gauss meter : -4.89e-05
    Right Arm Q2 power supply current : -4.43687e-05
    Right Arm Q2 momentum : -1.03095e-07
    Right Arm Q2 gauss meter : 0.0004266
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 3.0376
    Right Arm D1 momentum : 0.0368272
    Right Arm D1 NMR : 1.88387
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : -0.00541391
    Right Arm Q3 momentum : -1.36059e-05
    Right Arm Q3 gauss meter : 4.66e-05
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 2.28856
    Current on Unser monitor : 19.5672
    Current on Upstream bcm : 2.22651
    Current on Downstream bcm : 2.3506
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 2.477
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6066.8
    Hall A momentum orbit correction (dpp) : -0.000107883
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6066.8
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.0548634
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -0.226932
    IPM1H04A.YPOS : 2.29142
    IPM1H04B.XPOS : -0.535905
    IPM1H04B.YPOS : 2.62959
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 60
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : L1 20cm
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 3.30777e+07
    Target type : 3.30777e+07
    temperature loop 1(1) : 21.99
    temperature loop 1(2) : 21.95
    temperature loop 1(3) : 22.27
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 277.9
    HPH H2 loop 1 : 1078.27
    HPH H2 loop 3 : 0.011068