Privacy and Security Notice

End_of_Run_25250


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 04:22:26 on November 6, 2009

    Entry number 297713

    keyword=End_of_Run_25250
    ****************************
     Run Number: 25250
     End of Run Comment:
    Run_type=Qsq,target_type=Liquid H2, 20cm,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=Qsq on L-HRS
     
    
    PRESCALE FACTORS:ps1=10   ps2=99999   ps3=99999   ps4=99999   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 367116       
    TIME     : [0]: 7.268 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  -0.06%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :841.1/8411.2 Hz   T2[0] : 0.0/84.5 Hz   T3[0] : 0.0/1666.5 Hz   T4[0] : 0.0/1693.0 Hz   T5[0] : 0.0/2114.6 Hz   T6[0] : 0.0/96.7 Hz   T7[0] : 0.2/12509.8 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 366790/3667908  T2[0] :      0/36866    T3[0] :      7/726712   T4[0] :      7/738293   T5[0] :     14/922130   T6[0] :      0/42171    T7[0] :     83/5455183  T8[0] :      6/446540   
    
    AVERAGE CURRENT
    BCM x1 : 2.1276 uA  BCM x3 : 0.5441 uA  BCM x10: 2.1488 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0009252      BCM u3 [0]:0.0004819      BCM u10[0]:0.0009345      
    
    BCM d1 [0]:0.0009304      BCM d3 [0]:-7.35E-06      BCM d10[0]:0.0009395      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25250 at Fri Nov 6 04:22:22 EST 2009
    
    Left Arm Top VDC Current : 3.32031
    Left Arm Bottom VDC Current : 1.07422
    Left Arm Top VDC voltage : 3.99414
    Left Arm Bottom VDC voltage : 4.00049
    -----
    Right Arm Top VDC Current : -1.85547
    Right Arm Bottom VDC Current : -1.46484
    Right Arm Top VDC voltage : -0.0102539
    Right Arm Bottom VDC voltage : -0.0102539
    -----
    Left Arm Q1 momentum : 3.66043
    Left Arm Q1 power supply : 2753.86
    Left Arm Q1 gauss meter : -0.23216
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Q2 power supply current : 1575.84
    Left Arm Q2 momentum : 3.65963
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.23
    Left Arm D1 momentum : 3.66004
    Left Arm D1 NMR : 1.35576
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73462
    Left Arm Q3 power supply current : 1457.23
    Left Arm Q3 momentum : 3.66029
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 0.00135737
    Right Arm Q1 power supply : 0.106813
    Right Arm Q1 gauss meter : -4.03e-05
    Right Arm Q2 power supply current : -0.000384529
    Right Arm Q2 momentum : -7.21665e-07
    Right Arm Q2 gauss meter : 0.0004335
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 2.99347
    Right Arm D1 momentum : 0.036323
    Right Arm D1 NMR : 1.14563
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : -0.00521214
    Right Arm Q3 momentum : -1.40472e-05
    Right Arm Q3 gauss meter : 4.62e-05
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 2.26938
    Current on Unser monitor : 18.7225
    Current on Upstream bcm : 2.21053
    Current on Downstream bcm : 2.32823
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 2.4574
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.36
    Hall A momentum orbit correction (dpp) : -1.58028e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.36
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.0548662
    IPM1C12.XPOS : -0.00355178
    IPM1H04A.XPOS : -0.123018
    IPM1H04A.YPOS : 2.25855
    IPM1H04B.XPOS : -0.424977
    IPM1H04B.YPOS : 2.56012
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 60
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : L1 20cm
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 3.30777e+07
    Target type : 3.30777e+07
    temperature loop 1(1) : 22
    temperature loop 1(2) : 21.96
    temperature loop 1(3) : 22.28
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 277.8
    HPH H2 loop 1 : 1040.47
    HPH H2 loop 3 : 0.011068