    Log entry time 05:07:08 on November 6, 2009

    Entry number 297728

    keyword=End_of_Run_25253
    ****************************
     Run Number: 25253
     End of Run Comment:
    Run_type=Qsq,target_type=Liquid H2, 20cm,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=spot++
     
    
    PRESCALE FACTORS:ps1=65535   ps2=99999   ps3=99999   ps4=99999   ps5=65535   ps6=65535   ps7=65535   ps8=10   
    
    EVENTS   : [0]: 38682        
    TIME     : [0]: 5.817 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   1.96%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 4.2/272104.8 Hz   T2[0] : 0.1/5326.8 Hz   T3[0] : 0.6/55936.5 Hz   T4[0] : 0.6/56661.7 Hz   T5[0] : 1.0/66812.8 Hz   T6[0] : 0.0/2174.9 Hz   T7[0] : 4.3/279909.9 Hz   T8[0] :102.4/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   1449/94964317  T2[0] :     18/1859058  T3[0] :    195/19521788  T4[0] :    197/19774875  T5[0] :    355/23317608  T6[0] :     11/759048   T7[0] :   1490/97688286  T8[0] :  35737/357375   
    
    AVERAGE CURRENT
    BCM x1 : 73.0462uA  BCM x3 : 18.6189uA  BCM x10: 44.6339uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.02533        BCM u3 [0]:0.013          BCM u10[0]:0.01601        
    
    BCM d1 [0]:0.02566        BCM d3 [0]:-5.882E-06     BCM d10[0]:0.01515        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25253 at Fri Nov 6 05:07:04 EST 2009
    
    Left Arm Top VDC Current : 1.41602
    Left Arm Bottom VDC Current : 1.46484
    Left Arm Top VDC voltage : 0.0170898
    Left Arm Bottom VDC voltage : 0.0185547
    -----
    Right Arm Top VDC Current : -1.66016
    Right Arm Bottom VDC Current : -1.41602
    Right Arm Top VDC voltage : -0.0102539
    Right Arm Bottom VDC voltage : -0.0102539
    -----
    Left Arm Q1 momentum : 3.66029
    Left Arm Q1 power supply : 2753.75
    Left Arm Q1 gauss meter : -0.23214
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.84
    Left Arm Q2 momentum : 3.65963
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.22
    Left Arm D1 momentum : 3.66004
    Left Arm D1 NMR : 1.35576
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73461
    Left Arm Q3 power supply current : 1457.22
    Left Arm Q3 momentum : 3.66027
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 0.00150053
    Right Arm Q1 power supply : 0.0534066
    Right Arm Q1 gauss meter : -3.87e-05
    Right Arm Q2 power supply current : 0.000144198
    Right Arm Q2 momentum : 0.00199196
    Right Arm Q2 gauss meter : 0.0004326
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 2.80841
    Right Arm D1 momentum : 0.0335459
    Right Arm D1 NMR : 1.35714
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : -0.00559325
    Right Arm Q3 momentum : -1.40566e-05
    Right Arm Q3 gauss meter : 4.71e-05
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 83.4625
    Current on Unser monitor : 100.056
    Current on Upstream bcm : 81.4843
    Current on Downstream bcm : 85.4407
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 84.4051
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.41
    Hall A momentum orbit correction (dpp) : -4.17809e-06
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.43
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.0548545
    IPM1C12.XPOS : -0.00498044
    IPM1H04A.XPOS : -0.0948303
    IPM1H04A.YPOS : 2.38906
    IPM1H04B.XPOS : -0.381851
    IPM1H04B.YPOS : 2.7138
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 112
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : L1 20cm
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 3.30777e+07
    Target type : 3.30777e+07
    temperature loop 1(1) : 22.02
    temperature loop 1(2) : 21.97
    temperature loop 1(3) : 22.5
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.7
    Heat exchange LH2 : 277.5
    HPH H2 loop 1 : 440.45
    HPH H2 loop 3 : 0.00293052