NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 05:14:35 on November 6, 2009
Entry number 297731
keyword=End_of_Run_25254
****************************
Run Number: 25254
End of Run Comment:
Run_type=Qsq,target_type=Liquid H2, 20cm,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=spot++
PRESCALE FACTORS:ps1=65535 ps2=99999 ps3=99999 ps4=99999 ps5=65535 ps6=65535 ps7=65535 ps8=10
EVENTS : [0]: 398
TIME : [0]: 0.205 mins
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 71.75%
TRIGGER RATES: PRES/REAL
T1[0] : 4.6/304214.0 Hz T2[0] : 0.0/5947.6 Hz T3[0] : 0.6/62678.5 Hz T4[0] : 0.6/63433.6 Hz T5[0] : 1.1/74777.8 Hz T6[0] : 0.0/2491.8 Hz T7[0] : 4.7/312895.8 Hz T8[0] :102.4/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 57/3749200 T2[0] : 0/73299 T3[0] : 7/772463 T4[0] : 7/781770 T5[0] : 14/921578 T6[0] : 0/30709 T7[0] : 58/3856197 T8[0] : 1262/12620
AVERAGE CURRENT
BCM x1 : 83.1400uA BCM x3 : 20.8198uA BCM x10: 49.1826uA
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.001018 BCM u3 [0]:0.0005134 BCM u10[0]:0.000625
BCM d1 [0]:0.001031 BCM d3 [0]:-2.077E-07 BCM d10[0]:0.0005873
****************************
End-of-run EPICS data for Run Number 25254 at Fri Nov 6 05:14:32 EST 2009
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.5625
Left Arm Top VDC voltage : 0.0185547
Left Arm Bottom VDC voltage : 0.019043
-----
Right Arm Top VDC Current : -1.85547
Right Arm Bottom VDC Current : -1.41602
Right Arm Top VDC voltage : -0.0102539
Right Arm Bottom VDC voltage : -0.0107422
-----
Left Arm Q1 momentum : 3.66036
Left Arm Q1 power supply : 2753.75
Left Arm Q1 gauss meter : -0.23213
Left Arm Q2 gauss meter : 0.8272
Left Arm Q2 power supply current : 1575.84
Left Arm Q2 momentum : 3.65963
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1325.22
Left Arm D1 momentum : 3.66004
Left Arm D1 NMR : 1.35576
Left Arm arm angle : 12.8988
Left Arm Q3 gauss meter : -0.73459
Left Arm Q3 power supply current : 1457.23
Left Arm Q3 momentum : 3.66028
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 0.00158006
Right Arm Q1 power supply : 0.106813
Right Arm Q1 gauss meter : -4.04e-05
Right Arm Q2 power supply current : 5.54609e-05
Right Arm Q2 momentum : 0.0019977
Right Arm Q2 gauss meter : 0.0004311
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 2.78275
Right Arm D1 momentum : 0.0331099
Right Arm D1 NMR : 1.12741
Right Arm arm angle : 20.001
Right Arm Q3 power supply current : -0.00563061
Right Arm Q3 momentum : -1.41505e-05
Right Arm Q3 gauss meter : 4.82e-05
Right Arm Q3 power supply polarity : disabled
-----
Average current of the two cavities : 84.3951
Current on Unser monitor : 100.267
Current on Upstream bcm : 82.3239
Current on Downstream bcm : 86.4662
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 85.1272
Hall C Current : 0
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
Hall A momentum (Tiefenbach) (HALLA:p) : 6067.45
Hall A momentum orbit correction (dpp) : -1.19915e-06
Hall A setup momentum (MMSHLAE) : 6067.5
Hall A energy (halla_MeV) : 6067.45
Hall C energy (hallc_MeV) : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.0548782
IPM1C12.XPOS : 0.0208164
IPM1H04A.XPOS : -0.0838591
IPM1H04A.YPOS : 2.35008
IPM1H04B.XPOS : -0.362119
IPM1H04B.YPOS : 2.66718
-----
Wien angle : 74.7279
Wien BDL : 1724.8
Wien field : 49.796
Laser attenuation Hall A : 112
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 1200
Beam Half-wave plate (off=out) : OUT
-----
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern : Quartet
-----
Target : L1 20cm
fan frequency loop 1 : 59.5
fan frequency loop 3 : 0
Encoder position : 3.30777e+07
Target type : 3.30777e+07
temperature loop 1(1) : 21.99
temperature loop 1(2) : 21.94
temperature loop 1(3) : 22.46
temperature loop 3(1) : 99.99
temperature loop 3(2) : 99.99
temperature loop 3(3) : 29.99
Heat exchange LH2 : 24.7
Heat exchange LH2 : 277.4
HPH H2 loop 1 : 431.633
HPH H2 loop 3 : 9.38936e-06