Privacy and Security Notice

End_of_Run_25255


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 05:17:58 on November 6, 2009

    Entry number 297735

    keyword=End_of_Run_25255
    ****************************
     Run Number: 25255
     End of Run Comment:
    Run_type=Qsq,target_type=Liquid H2, 20cm,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=spot++
    
    
    PRESCALE FACTORS:ps1=65535   ps2=99999   ps3=99999   ps4=99999   ps5=65535   ps6=65535   ps7=65535   ps8=3   
    
    EVENTS   : [0]: 60200        
    TIME     : [0]: 3.000 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   4.33%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 3.2/209932.1 Hz   T2[0] : 0.0/3931.1 Hz   T3[0] : 0.4/43162.9 Hz   T4[0] : 0.4/43717.0 Hz   T5[0] : 0.8/51567.5 Hz   T6[0] : 0.0/1604.4 Hz   T7[0] : 3.3/217138.0 Hz   T8[0] :341.3/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :    576/37788387  T2[0] :      7/707609   T3[0] :     77/7769452  T4[0] :     78/7869189  T5[0] :    141/9282302  T6[0] :      4/288798   T7[0] :    596/39085481  T8[0] :  61441/184323   
    
    AVERAGE CURRENT
    BCM x1 : 57.7493uA  BCM x3 : 14.3573uA  BCM x10: 36.5828uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01033        BCM u3 [0]:0.005172       BCM u10[0]:0.006743       
    
    BCM d1 [0]:0.01046        BCM d3 [0]:-3.034E-06     BCM d10[0]:0.006427       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25255 at Fri Nov 6 05:17:54 EST 2009
    
    Left Arm Top VDC Current : 1.36719
    Left Arm Bottom VDC Current : 1.51367
    Left Arm Top VDC voltage : 0.0180664
    Left Arm Bottom VDC voltage : 0.0180664
    -----
    Right Arm Top VDC Current : -1.9043
    Right Arm Bottom VDC Current : -1.41602
    Right Arm Top VDC voltage : -0.0102539
    Right Arm Bottom VDC voltage : -0.0112305
    -----
    Left Arm Q1 momentum : 3.66036
    Left Arm Q1 power supply : 2753.86
    Left Arm Q1 gauss meter : -0.23214
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.84
    Left Arm Q2 momentum : 3.65963
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.22
    Left Arm D1 momentum : 3.66004
    Left Arm D1 NMR : 1.35576
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73459
    Left Arm Q3 power supply current : 1457.22
    Left Arm Q3 momentum : 3.66027
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 0.00135207
    Right Arm Q1 power supply : 0.106813
    Right Arm Q1 gauss meter : -3.33e-05
    Right Arm Q2 power supply current : -0.000210751
    Right Arm Q2 momentum : -7.73213e-08
    Right Arm Q2 gauss meter : 0.000423
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 2.77122
    Right Arm D1 momentum : 0.03293
    Right Arm D1 NMR : 1.16393
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : -0.00581743
    Right Arm Q3 momentum : -1.46482e-05
    Right Arm Q3 gauss meter : 4.66e-05
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 83.9151
    Current on Unser monitor : 100.382
    Current on Upstream bcm : 81.8181
    Current on Downstream bcm : 86.0121
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 84.6094
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.46
    Hall A momentum orbit correction (dpp) : -1.38167e-07
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.46
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.0548619
    IPM1C12.XPOS : 0.00785771
    IPM1H04A.XPOS : -0.0822427
    IPM1H04A.YPOS : 2.33512
    IPM1H04B.XPOS : -0.358976
    IPM1H04B.YPOS : 2.64272
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 112
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : L1 20cm
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 3.30777e+07
    Target type : 3.30777e+07
    temperature loop 1(1) : 22
    temperature loop 1(2) : 21.96
    temperature loop 1(3) : 22.48
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.7
    Heat exchange LH2 : 277.4
    HPH H2 loop 1 : 491.711
    HPH H2 loop 3 : 0.000504939