Privacy and Security Notice

End_of_Run_4796


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 11:25:37 on November 6, 2009

    Entry number 297788

    keyword=End_of_Run_4796
    ****************************
     Run Number: 4796
     End of Run Comment:
    Run_type=Qsq,target_type=Liquid H2, 20cm,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=check out run for right GC with Bogdon
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=10   
    
    EVENTS   : [0]: 3384         
    TIME     : [0]: 0.678 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  18.74%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/13.7 Hz   T2[0] : 0.0/0.0  Hz   T3[0] : 0.0/114.2 Hz   T4[0] : 0.0/0.4  Hz   T5[0] : 0.0/70.0 Hz   T6[0] : 0.0/2.2  Hz   T7[0] : 0.0/2141.5 Hz   T8[0] :102.4/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      0/557      T2[0] :      0/0        T3[0] :      0/4645     T4[0] :      0/17       T5[0] :      0/2846     T6[0] :      0/89       T7[0] :      1/87066    T8[0] :   4163/41633    
    
    AVERAGE CURRENT
    BCM x1 : -0.0750uA  BCM x3 : 0.1144 uA  BCM x10: -0.0081uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-6.212E-06     BCM u3 [0]:9.984E-06      BCM u10[0]:-6.05E-07      
    
    BCM d1 [0]:1.173E-07      BCM d3 [0]:-6.852E-07     BCM d10[0]:-5.14E-08      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4796 at Fri Nov 6 11:25:33 EST 2009
    
    Left Arm Top VDC Current : 1.46484
    Left Arm Bottom VDC Current : 1.51367
    Left Arm Top VDC voltage : 0.0180664
    Left Arm Bottom VDC voltage : 0.019043
    -----
    Right Arm Top VDC Current : -1.85547
    Right Arm Bottom VDC Current : -1.41602
    Right Arm Top VDC voltage : -0.00976562
    Right Arm Bottom VDC voltage : -0.0107422
    -----
    Left Arm Q1 momentum : 3.66043
    Left Arm Q1 power supply : 2753.86
    Left Arm Q1 gauss meter : -0.23216
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.84
    Left Arm Q2 momentum : 3.65964
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.23
    Left Arm D1 momentum : 3.66004
    Left Arm D1 NMR : 1.35576
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73458
    Left Arm Q3 power supply current : 1457.21
    Left Arm Q3 momentum : 3.66024
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 0.00108696
    Right Arm Q1 power supply : 0.106813
    Right Arm Q1 gauss meter : -4.95e-05
    Right Arm Q2 power supply current : -0.0144901
    Right Arm Q2 momentum : -3.36691e-05
    Right Arm Q2 gauss meter : 0.0004318
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 2.21701
    Right Arm D1 momentum : 0.020816
    Right Arm D1 NMR : 1.34541
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : -0.0066693
    Right Arm Q3 momentum : -1.67609e-05
    Right Arm Q3 gauss meter : 4.76e-05
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 0.025658
    Current on Unser monitor : 17.4517
    Current on Upstream bcm : 0.0371745
    Current on Downstream bcm : 0.0141415
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.315337
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377197
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.46
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.46
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.0548805
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 60
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Empty
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 3.20255e+06
    Target type : 3.20255e+06
    temperature loop 1(1) : 22.02
    temperature loop 1(2) : 21.97
    temperature loop 1(3) : 22.3
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 275.6
    HPH H2 loop 1 : 1243.63
    HPH H2 loop 3 : 9.38936e-06